| AC Test Voltage | 150 kV |
| Operation System | Motorized Console |
| Capacity | 10 kVA |
| Delivery Time | 30 Working Days |
| Payment Terms | L/C,T/T |
| Measurement System | Voltage Divider |
| Packaging Details | Plywood Case |
| Test Category | Power Frequency AC Withstand |
| Transformer Type | PD-Free Test Transformer |
| Model Number | YDW |
| Brand Name | Sansion Power |
| Certification | CE/SGS/EMS/ISO 9001 |
| Place of Origin | China |
View Detail Information
Explore similar products
5KVA 50KV Power Frequency Withstand Test System for Transformer Switchgear Cable
15 kVA 150 kV Power Frequency AC Withstand Voltage Test System for Electrical
15 kVA 150 kV Intelligent AC Withstand Test System with Motorized Voltage
Power Frequency Hipot Test Equipment AC Dielectric Withstand Tester for High
Product Specification
| AC Test Voltage | 150 kV | Operation System | Motorized Console |
| Capacity | 10 kVA | Delivery Time | 30 Working Days |
| Payment Terms | L/C,T/T | Measurement System | Voltage Divider |
| Packaging Details | Plywood Case | Test Category | Power Frequency AC Withstand |
| Transformer Type | PD-Free Test Transformer | Model Number | YDW |
| Brand Name | Sansion Power | Certification | CE/SGS/EMS/ISO 9001 |
| Place of Origin | China | ||
| High Light | 150kV dielectric withstand tester ,10kVA transformer testing system ,high voltage equipment inspection tester | ||
Product Name: 10kVA/150kV Power Frequency PD-Free AC Withstand Test System
Before electrical equipment is accepted or put into service, insulation performance must be verified against the required AC withstand level. The 10kVA/150kV Power Frequency PD-Free AC Withstand Test System provides a dedicated high-voltage testing solution for acceptance, commissioning and insulation verification procedures.
The equipment is centered around a 150kV PD-Free Test Transformer and supported by a Motorized Operation Console, Power Supply and Voltage Divider. During a test, the operator can progressively apply the required power-frequency AC voltage and monitor the corresponding high-voltage level. The PD-free configuration is especially useful when minimizing test-source discharge is an important part of the testing environment.
| Parameter | Specification |
|---|---|
| Capacity | 10 kVA |
| AC Test Voltage | 150 kV |
| Test Category | Power Frequency AC Withstand |
| Transformer | PD-Free Test Transformer |
| Operation System | Motorized Console |
| Measurement System | Voltage Divider |
| Primary Function | Dielectric Withstand Verification |
Q1: Can the system be used for acceptance testing?
A: Yes. It can be used for applicable power-frequency AC withstand tests during equipment acceptance and commissioning.
Q2: What type of transformer is included?
A: The system uses a PD-Free Test Transformer specifically configured for the testing system.
Q3: What is the system capacity?
A: The rated capacity is 10kVA, with a maximum AC test voltage of 150kV.
Q4: What equipment can be tested?
A: Suitable transformers and other electrical equipment requiring power-frequency AC dielectric withstand testing can be tested according to their applicable test requirements.
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
50000000-80000000
Employee Number:
120~150
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...
Get in touch with us
Leave a Message, we will call you back quickly!