Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"High Voltage Lightning Impulse and Switching Impulse Generator for Transformer,","imgUrl":"https:\/\/img.chinax.com\/nimg\/69\/b5\/1384c8a155e743eb38bdc177434e-200x200-1\/high_voltage_lightning_impulse_and_switching_impulse_generator_for_transformer_2c.jpg","attrs":{"Model Number":"SXCY","Energy Range":"7.31\u2013320 kJ","Minimum Order Quantity":"1","Impulse Capacitance":"0.0278\u20130.1625 \u03bcF"}}
{"title":"Turnkey Lightning Impulse Test System Voltage Generator Equipment for Power","imgUrl":"https:\/\/img.chinax.com\/nimg\/33\/0a\/1ece9c95b107d0a17d768076b3a0-200x200-1\/turnkey_lightning_impulse_test_system_voltage_generator_equipment_for_power_transformer_2c_insulator_26_surge_arrester_testing_281.jpg","attrs":{"Model Number":"SXCF","Minimum Order Quantity":"1","Brand Name":"Sansion","Control Type":"Computer Control"}}
{"title":"Advanced Digital Lightning Impulse Voltage Testing Equipment with Automated","imgUrl":"https:\/\/img.chinax.com\/nimg\/4b\/e8\/c656b1f4874b627a389e78045763-200x200-1\/advanced_digital_lightning_impulse_voltage_testing_equipment_with_automated_waveform_analysis_system_for_high_voltage_r_26d_labora.jpg","attrs":{"Model Number":"SXCF","Measurement Parameters":"Front time (T1), time to half-value (T2), peak voltage, chopping time","Minimum Order Quantity":"1","Anti-Interference Features":"Optical isolation, shielded digital processing units"}}
{"title":"Modular Lightning Impulse Voltage Generator Testing System for Electrical","imgUrl":"https:\/\/img.chinax.com\/nimg\/45\/41\/d4d51aef00fa819a28071d0c91ac-200x200-1\/modular_lightning_impulse_voltage_generator_testing_system_for_electrical_manufacturers_quality_control_inspection_labs_28_c2_b110.jpg","attrs":{"Model Number":"SXCF","Waveform types":"Standard lightning full waves, chopped waves, eight distinct impulse voltage waveforms","Minimum Order Quantity":"1","Measurement parameters":"Front time (T1), time to half-value (T2), peak voltage, chopping time"}}
{"title":"Heavy-Duty Impulse Voltage Generator & Lightning Testing System for Power","imgUrl":"https:\/\/img.chinax.com\/nimg\/c4\/35\/39d4a7a37fcb3386c656e63af222-200x200-1\/heavy_duty_impulse_voltage_generator_26_lightning_testing_system_for_power_transmission_grids_2c_gis_26_power_cable_testing_283600.jpg","attrs":{"Anti-Interference Features":"Optical isolation, shielded digital processing units","Model Number":"SXCF","Waveform Types":"Standard lightning full waves, chopped waves, eight distinct impulse voltage waveforms","Minimum Order Quantity":"1"}}
{"title":"Customizable Impulse Voltage Generator Automatic Control High Voltage Surge Test","imgUrl":"https:\/\/img.chinax.com\/nimg\/28\/a0\/97c16182599b80bd90440f7740ca-200x200-1\/customizable_impulse_voltage_generator_automatic_control_high_voltage_surge_test_equipment_for_electrical_insulation_performance_t.jpg","attrs":{"Model Number":"SXCY","Output Energy":"7.31\u2011320kJ Multi\u2011level Optional","Minimum Order Quantity":"1","Circuit Design":"Low\u2011inductance circuit with resistance\u2011filtering structure"}}
{"title":"Professional Lightning Impulse Test System for Power Transformer Manufacturing","imgUrl":"https:\/\/img.chinax.com\/nimg\/b9\/77\/71851d10067fa6ab7a292929d57b-200x200-1\/professional_lightning_impulse_test_system_for_power_transformer_manufacturing_substation_equipment_and_high_voltage_laboratory_vo.jpg","attrs":{"Model Number":"SXCY","Voltage performance":"Stable operation","Minimum Order Quantity":"1","Standard compliance":"IEC testing requirements"}}
The SXCY Series Impulse Voltage & Current Generator is a high-energy testing platform developed for high-voltage laboratories, transformer manufacturers, power equipment manufacturers and electrical testing organizations.
With a modular multi-stage configuration, the system provides rated voltage options from ±100 kV to ±4800 kV, with 1 to 24 stages and impulse energy up to 320 kJ.
Application
Power Transformer Used as part of transformer impulse testing systems for evaluating transformer insulation structures and associated high-voltage components.
GIS & Switchgear Suitable for impulse testing arrangements involving GIS, circuit breakers, disconnectors and other high-voltage switching equipment.
Power Cable Can be incorporated into impulse testing systems for power cables and cable accessories.
Bushings & Insulators Provides an impulse source for high-voltage insulation component testing.
Surge Protection Equipment Can be integrated into suitable test circuits for impulse-related evaluation of surge protection equipment.
Technical Parameters
Parameter
Specification
Rated Voltage
±100 to ±4800 kV
Stage Voltage
±100 / ±150 / ±200 kV
Number of Stages
1–24
Impulse Capacitance
0.0278–0.1625 μF
Grading Capacitance
0.325–1 μF
Charging Voltage
±100 / ±150 / ±200 kV
Impulse Energy
7.31–320 kJ
Configuration Portfolio
Rated Voltage
Stages
Impulse Energy
±100–±400 kV
1–4
7.31–33.74 kJ
±300–±900 kV
2–6
7.31–33.74 kJ
±1050–±1500 kV
7–10
25.58–56.25 kJ
±1600–±2400 kV
8–12
80–240 kJ
±2800–±3200 kV
14–16
140–320 kJ
±3600–±4800 kV
18–24
80–240 kJ
FAQ
What is an impulse voltage generator used for? It generates controlled high-voltage impulses for testing the insulation performance of electrical equipment and high-voltage components.
What is the maximum rated voltage of the SXCY Series? The available rated voltage range extends to ±4800 kV.
How many stages can be configured? The SXCY Series supports 1 to 24 stages depending on the required voltage and system configuration.
How much impulse energy can it provide? The listed configurations provide impulse energy from 7.31 kJ to 320 kJ.
Can it be used for transformer testing? Yes. The SXCY Series can be incorporated into a suitable transformer impulse testing system.
Can you supply a complete testing system? The impulse generator can be integrated with the corresponding charging, control, measurement and auxiliary equipment according to the project requirements.
How should I select the configuration? Please provide your test object, required test voltage and intended application. These parameters can be used as the starting point for determining the appropriate generator configuration.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
50000000-80000000
Employee Number:
120~150
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...