China Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer
China Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer

  1. China Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer
  2. China Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer
  3. China Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer

Portable Transformer On-Load Tap Changer Tester OLTC Tester for Transformer

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Measurement Accuracy Transition Resistance: ±(Reading * 5% + 0.1Ω), Transition Time: ±1ms
Delivery Time 5-30 work days
Working Power Supply AC220V ± 10%
Payment Terms T/T,L/C
Transition Resistance Range 1A gear: 1.0Ω ~ 20Ω, 0.5A gear: 5.0Ω ~ 40Ω, 0.3A gear: 6.0Ω ~ 60Ω
Packaging Details plywood case
Display Screen 7-Inch Industrial Touch Color Screen
Transition Time Range 0.1ms ~ 300ms
Output Current Gears 0.3A, 0.5A, 1A Adjustable
Model Number SXYZ
Certification CE SGS ISO9001
Brand Name Sansion
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Measurement Accuracy Transition Resistance: ±(Reading * 5% + 0.1Ω), Transition Time: ±1ms Delivery Time 5-30 work days
Working Power Supply AC220V ± 10% Payment Terms T/T,L/C
Transition Resistance Range 1A gear: 1.0Ω ~ 20Ω, 0.5A gear: 5.0Ω ~ 40Ω, 0.3A gear: 6.0Ω ~ 60Ω Packaging Details plywood case
Display Screen 7-Inch Industrial Touch Color Screen Transition Time Range 0.1ms ~ 300ms
Output Current Gears 0.3A, 0.5A, 1A Adjustable Model Number SXYZ
Certification CE SGS ISO9001 Brand Name Sansion
Place of Origin China
High Light Portable OLTC tester for transformer maintenanceOn-load tap changer tester for substationsTransformer OLTC tester with preventive maintenance
Product Introduce

This instrument is designed for comprehensive analysis of transformer on-load tap changer (OLTC) operating performance, including transition waveform recording, transition time measurement, transition resistance evaluation, and three-phase synchronization analysis.
By capturing the dynamic characteristics during tap switching, it helps identify potential issues such as contact wear, abnormal transition processes, and mechanical synchronization deviations, providing reliable data support for transformer maintenance and quality inspection.
Equipped with an intelligent test system and intuitive menu-driven operation, the device enables technicians to complete OLTC performance assessments efficiently. Its compact structure, lightweight design, and excellent anti-interference capability make it suitable for both laboratory testing and on-site diagnostics.
It is widely applied by power utilities, transformer manufacturers, and maintenance organizations for transformer commissioning, preventive maintenance, and production quality control.

Highlight

1.High-Precision Low Resistance Measurement Capability
Designed with high-current output technology, the tester provides stable and accurate measurements of low transition resistance values, enabling reliable evaluation of the dynamic performance and contact condition of transformer on-load tap changers.


2.Flexible Current Selection for Different Applications
Multiple output current levels are available to accommodate various transformer tap changer models and testing requirements, offering greater adaptability for laboratory inspection and on-site maintenance tasks.


3.Comprehensive Protection System for Safe Operation
Integrated protection functions effectively safeguard the instrument and the tested equipment against abnormal conditions such as overcurrent, overvoltage, and improper operation, ensuring stable performance during field testing.


4.Industrial-Grade Touch Display for Clear Outdoor Operation
The instrument is equipped with a 7-inch high-resolution industrial color touchscreen (1024*600 pixels) featuring a wide viewing angle and 400cd/m² brightness. The explosion-resistant glass touch panel enhances durability and visibility, even in demanding outdoor environments.


5.Dual-Control Interface for Reliable Testing Operation
Combining a multifunctional control knob with touchscreen operation, the dual-input design provides operational flexibility and backup control options. The upgraded user interface simplifies test procedures and improves overall efficiency for field engineers.


6.Advanced Data Management and Waveform Analysis
A built-in thermal printer allows immediate test report printing, while internal memory and USB data export functions provide convenient record management. Compatible PC analysis software enables detailed waveform review and supports efficient diagnosis of OLTC switching performance.

Specification
Device Model SXYZ-2008
Output Current 1A, 0.5A, 0.3A (3 gears optional)
Transition Resistance Measurement Range 1A gear: 1.0Ω ~ 20Ω
0.5A gear: 5.0Ω ~ 40Ω
0.3A gear: 6.0Ω ~ 60Ω
Transition Time Measurement Range 0.1ms ~ 300ms
Measurement Accuracy Transition Resistance: ±(Reading * 5% + 0.1Ω)
Transition Time: ±1ms
Resolution Transition Resistance: 0.01Ω
Transition Time: 0.1ms
Working Power Supply AC220V ± 10%
Power Frequency 50/60Hz
Operating Temperature -10°C ~ 50°C
Relative Humidity ≤90% (non-condensing)
Host Weight 4.7kg (excluding test cables)
Host Dimensions 325mm * 225mm * 125mm
FAQ
  • What is an On Load Tap Changer Tester?

    A:An On Load Tap Changer (OLTC) Tester is a professional diagnostic instrument designed to analyze the switching performance and operational condition of transformer on-load tap changers without removing them from the transformer system.
    The SXYZ-2008 On Load Tap Changer Tester evaluates the dynamic characteristics of OLTC switching operations by recording and analyzing key parameters, including:
    • Transition waveform
    • Transition time
    • Transition resistance
    • Three-phase switching synchronization
    By providing detailed switching behavior data, the tester helps engineers identify abnormal OLTC operation, verify transformer performance, and support preventive maintenance decisions.

  • Why is OLTC testing important for power transformers?

    A:The on-load tap changer (OLTC) is one of the most frequently operated components in a transformer and plays a critical role in maintaining stable output voltage.
    During long-term operation, electrical arcing, contact aging, mechanical wear, or improper switching actions may affect OLTC performance. Regular OLTC testing helps detect potential problems before they develop into transformer failures.
    The SXYZ-2008 helps assess:
    • Abnormal transition resistance changes
    • Irregular switching time
    • Contact condition degradation
    • Phase synchronization deviation
    • Possible mechanical switching defects
    Through dynamic switching analysis, maintenance teams can improve transformer reliability and reduce unexpected downtime.

  • What parameters can the SXYZ-2008 OLTC Tester measure?

    A:The SXYZ-2008 On Load Tap Changer Tester can measure:
    • Transition waveform
    • Transition time
    • Transition resistance
    • Three-phase synchronization
    It is mainly used for analyzing the switching process of transformer on-load tap changers and evaluating their operating condition.

  • What output current ranges does the SXYZ-2008 OLTC Tester provide?

    A:The SXYZ-2008 supports multiple test current selections to adapt to different transformer OLTC configurations and transition resistance measurement requirements.
    Available output current ranges include:
    • 1A
    • 0.5A
    • 0.3A
    The flexible current selection allows technicians to perform accurate transition resistance measurements on various types of on-load tap changers.

  • Is the SXYZ-2008 suitable for transformer manufacturers and power utilities?

    A:Yes. The SXYZ-2008 On Load Tap Changer Tester is designed for a wide range of transformer testing applications, including:
    • Transformer manufacturing inspection
    • Transformer commissioning tests
    • Power system maintenance
    • Preventive condition assessment
    • Electrical testing laboratory analysis
    It provides reliable OLTC performance data for transformer manufacturers, power utilities, and maintenance service providers to improve quality control and ensure safe transformer operation.

About Sanison

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Total Annual:

    50000000-80000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.sansionpower.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement