| Delivery Time | 30 work days |
| Detector sensitivity | 0.01pC |
| Measurement accuracy | Voltage & current <1% |
| Payment Terms | T/T,L/C |
| Transformer capacity | 20kVA |
| Packaging Details | plywood case |
| Background PD level | ≤2pC |
| Rated output voltage | 150kV |
| Operating frequency range | 45–200Hz |
| Model Number | SXJFT |
| Certification | CE SGS ISO9001 |
| Brand Name | Sansion |
| Place of Origin | China |
View Detail Information
Explore similar products
Digital Partial Discharge Measurement System with 0.01pC Sensitivity for High
High Voltage Partial Discharge Testing System 150kV 20kVA for Transformer
150kV 20kVA High Voltage Partial Discharge Testing Equipment with Coupling
Automated High Voltage Partial Discharge Detection System with Digital
Product Specification
| Delivery Time | 30 work days | Detector sensitivity | 0.01pC |
| Measurement accuracy | Voltage & current <1% | Payment Terms | T/T,L/C |
| Transformer capacity | 20kVA | Packaging Details | plywood case |
| Background PD level | ≤2pC | Rated output voltage | 150kV |
| Operating frequency range | 45–200Hz | Model Number | SXJFT |
| Certification | CE SGS ISO9001 | Brand Name | Sansion |
| Place of Origin | China | ||
| High Light | 150kV partial discharge test system ,variable frequency power supply PD tester ,PD-free test transformer electrical testing | ||
Sansion Power’s Integrated High Voltage Partial Discharge Measurement System combines a digital PD detector, variable-frequency AC power supply, high-voltage test transformer, coupling capacitor, voltage divider, and supporting components into one coordinated testing solution.
Designed for high-voltage insulation testing, the system provides adjustable-frequency AC output and digital partial discharge measurement. Its integrated configuration helps simplify test setup, coordinate voltage application and signal acquisition, and support consistent recording and analysis of test results.
The suitability of the system for a particular test object depends on its capacitance, required test voltage, test frequency, and applicable standard.
Q1: What is the rated output voltage of this system?
The complete system has a rated output voltage of 150kV.
Q2: What is the sensitivity of the PD detector?
The stated detector sensitivity is 0.01pC. This should not be interpreted as the background PD level of the complete system.
Q3: What is the background PD level of the complete system?
The specification states ≤2pC at rated voltage under no-load conditions.
Q4: Can the test frequency be adjusted?
Yes. The specified operating frequency range is 45–200Hz.
Q5: Can test results be saved and exported for reporting?
The detector supports data storage, playback, printing, and report generation. Please confirm the required report format and data export workflow when configuring the system.
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
50000000-80000000
Employee Number:
120~150
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...
Get in touch with us
Leave a Message, we will call you back quickly!