Payment Terms | T/T, L/C |
Supply Ability | 400 units/ month |
Delivery Time | 10-35 days |
Packaging Details | Plywood case |
Type | Air Cooled Type |
Capacity | 60HP |
Compressor typetype | Danfoss/Panosonic/Copeland |
Refrigerant | R410a/R407C/R134A/R22 |
Pump | Included 2 bar- 4 bar |
Water tank | 345L |
Voltage | 3PH~220V/380/415V~50HZ/60HZ |
Dimension(l*w*h) | 2700*2200*2050 |
Weight | 1850kg |
Temperature range | 5℃ ~ 35℃ |
Application | Industrial Cooling Solutions,Plastic & rubber / Chemical etc / Welding |
Brand Name | ANGES |
Model Number | ACK-60(F) |
Place of Origin | China |
View Detail Information
Explore similar products
20ton Water Chiller Price Air Cooled Chiller glycol water chiller Modular
Portable 60Tr Air Cooled chiller Scroll compressor chiller Air Cooled Industrial
Air Cooled Water Chiller 12hp 12Ton Injection Molding Chiller portable chiller
5Ton chiller 5HP Portable chiller Injection Molding Chiller Air Cooled Chiller
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 400 units/ month |
Delivery Time | 10-35 days | Packaging Details | Plywood case |
Type | Air Cooled Type | Capacity | 60HP |
Compressor typetype | Danfoss/Panosonic/Copeland | Refrigerant | R410a/R407C/R134A/R22 |
Pump | Included 2 bar- 4 bar | Water tank | 345L |
Voltage | 3PH~220V/380/415V~50HZ/60HZ | Dimension(l*w*h) | 2700*2200*2050 |
Weight | 1850kg | Temperature range | 5℃ ~ 35℃ |
Application | Industrial Cooling Solutions,Plastic & rubber / Chemical etc / Welding | Brand Name | ANGES |
Model Number | ACK-60(F) | Place of Origin | China |
High Light | 60 Ton Air Cooled Water Chiller ,345L Water Tank Industrial Water Chiller ,Injection Molding Machine Industrial Water Chiller |
60ton Air Cooled Industrial Water Chiller for injection molding Machine
The chiller has become an indispensable auxiliary equipment in the injection molding process through precise temperature control and efficient heat dissipation, directly improving production efficiency, product quality and economic benefits.
Choosing a suitable chiller can further optimize the production process and achieve cost reduction and efficiency improvement.
Specification
Item Model | ACK-60F | |
Nominal cooling capacity | Kcal/h | 158928 |
kw | 184.8 | |
Input power | kw | 57.48 |
Power supply | 3PH 380V 50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll |
Power(kw) | 49.8 | |
Condenser | Type | Finned copper tube + low noise outer rotor fan |
Power(kw) | 3.68 | |
Cooling air flow(m3/h) | 60000 | |
Evaporator | Type | Shell and tube |
Min Chilled fluid flow(m3/h) | 31.86 | |
Inlet/outlet pipe caliber(inch) | 3 | |
Water tank | Volume(L) | 345 |
Pump | Power(kw) | 4 |
Flow(m3/h) | 42 | |
Lift(m) | 21 | |
safety protection | compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection. | |
Weight | kg | 2260 |
Dimension | mm | 3400*2000*2053 |
The main role of the chiller for the injection molding machine
1.Shorten the molding cycle
Quickly take away the heat from the mold, accelerate the solidification of the plastic, and reduce the cooling time of a single product, thereby improving production efficiency.
2.Adapt to different material requirements
Flexibly adjust the water temperature and optimize material properties according to the cooling requirements of different plastics (such as ABS, PC, PP, etc.).
3.Protect molds and equipment
Prevent deformation or thermal fatigue of the mold due to long-term high-temperature operation and extend its service life.
4.Maintain production stability
Avoid shutdown of the injection molding machine due to overheating and ensure the stability of continuous production.
THE AFTER-SALE SERVICE OF ANGES CHILLER!
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
Company Details
Business Type:
Manufacturer,Importer,Exporter
Year Established:
2004
Total Annual:
40 Million-40 Million
Ecer Certification:
Verified Supplier
Anges Group which headquartered in Shenzhen city is specializes in the design and manufacture industrial process water chiller since 2004. We always adhered to the concept of "Environmental protection, Energy saving, Intelligent and Efficient" and have developed into a well-known supplier ... Anges Group which headquartered in Shenzhen city is specializes in the design and manufacture industrial process water chiller since 2004. We always adhered to the concept of "Environmental protection, Energy saving, Intelligent and Efficient" and have developed into a well-known supplier ...
Get in touch with us
Leave a Message, we will call you back quickly!