Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Type 2 Lab Water Purification System 30L\/H With TOC Monitoring","imgUrl":"https:\/\/img.chinax.com\/nimg\/3d\/c0\/b7b96adac094ed330901ae445d88-200x200-1\/type_2_lab_water_purification_system_30l_2fh_with_toc_monitoring.jpg","attrs":{"Brand Name":"Senova","Model Number":"TopPure30A-T1","Certification":"CE","Place of Origin":"China"}}
{"title":"Type I Type II Type III Laboratory Water Purification System MetaPure30N","imgUrl":"https:\/\/img.chinax.com\/nimg\/b6\/dd\/46e438695014027454063523944f-200x200-1\/type_i_type_ii_type_iii_laboratory_water_purification_system_metapure30n.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type III Pure RO Ultra Pure Laboratory Water Purification System HyPure","imgUrl":"https:\/\/img.chinax.com\/nimg\/1f\/86\/9dfe0180c053e7b54275bf8b3c07-200x200-1\/type_i_2f_type_iii_pure_ro_ultra_pure_laboratory_water_purification_system_hypure_30uv_with_point_of_use_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type 1 Ultra Pure Laboratory Water Purification System MaxPure-120PVF with Bio","imgUrl":"https:\/\/img.chinax.com\/nimg\/da\/66\/30f9069e5e4757924ed1ce626f79-200x200-1\/type_1_ultra_pure_laboratory_water_purification_system_maxpure_120pvf_with_bio_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I Type III RO \/ Pure \/ Ultra Pure Laboratory Water Purification System","imgUrl":"https:\/\/img.chinax.com\/nimg\/39\/f8\/64ada20cac10e0cc8f494296af02-200x200-1\/type_i_type_iii_ro_2f_pure_2f_ultra_pure_laboratory_water_purification_system_supure30vf_i.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type III RO \/ Pure \/ Ultra Pure Laboratory Water Purification System","imgUrl":"https:\/\/img.chinax.com\/nimg\/9d\/70\/26aa39e2ca5221058043e1d47260-200x200-1\/type_i_2f_type_iii_ro_2f_pure_2f_ultra_pure_laboratory_water_purification_system_supure30uv_i_with_point_of_use_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type III Laboratory Water Purification System TopPure30A-I","imgUrl":"https:\/\/img.chinax.com\/nimg\/ff\/7b\/eb1d207e1ae7f37fdeb4b51b5037-200x200-1\/type_i_2f_type_iii_laboratory_water_purification_system_toppure30a_i.jpg","attrs":{"Brand Name":"Senova","Model Number":"TopPure30A-I","Certification":"CE","Place of Origin":"China"}}
Automated Comprehensive Sanitization cycles preserve the integrity of the entire fluid pathway over time.
Quick-connect, module-designed consumables make maintenance simple and fast, reducing error risk.
The high-precision resistivity sensor is designed for continuous, reliable in-line measurement.
Its low cell constant and automatic temperature compensation provide stable, accurate readings for years.
System status is always clear on the large LCD, with timely reminders for cartridge replacement.
Durable, low-extractables PE tanks resist chemical leaching and include protective sensors.
Connectivity via RS232 allows for system integration into lab networks for sustained oversight.
For harsh feed water, the optional reinforced pretreatment with a 20" cartridge adds an extra durability layer.
The intuitive touch screen interface is built for daily, reliable interaction.
Optional online TOC serves as an early warning system for column exhaustion.
Remote dispensers extend system access without compromising core unit placement or function.
Configuration
TopPure-Series
TopPure30A-T1
Pretreatment module
○
High pressure pump
○
Reverse osmosis
○
Dual wavelength UV-lamp
○
Ultra-purification cartridge
○
Ultrafiltration cartridge
○
EDI Module
/
Point-of-use filter
○
Storage tank 30L
○
Air filter net for tank
○
UV-lamp sterilizer for water tank
○
Remote water dispenser with color display
○
TOC monitoring module
○
Specifications
Model
TopPure30A-T1
Feed Water Requirement
Source
Tap water
Conductivity*
<2000us/cm
Hardness**
<450ppm as CaCO3
Pressure
0.05~0.5MPa(7-72psi)
Temperature
5~40℃
Purification Water(Class III)
Ionic Rejection
>95%
Bacteria Rejection
>99%
Conductivity
1~20us/cm
Productivity Rate
30L/h
High Quality Purification Water(Class II)
Resistivity At 25℃
/
TOC
/
Dissolved Organic
/
Productivity Rate
/
Ultrapurification Water(Class I)
Resistivity At 25℃
18.2MΩ.cm
Conductivity At 25℃
0.055us/cm
TOC Level**
1~5ppb
Endotoxin(Pyrogens)****
<0.001EU/ml
Particulate(≥0.02µm)
<1pc/ml
Bacteria*
<0.1 cfu/ml
Rnase / Dnase**
Free
Manual dispense flow rate
1.5~2.0L/min
Automatic dispense volume
100~60000ml
Electrical Requirements
Electrical Voltage
110V/220V±10%
Electrical Frequency
50HZ/60HZ
Packing Information
Net Weight
Main units
34kg
Water tank (30L)
7kg
External Dimensions(WxDxH)
Main units
315x525x570mm
Water tank (30L)
380x380x595mm
Shipping weight
Main units
39kg
Water tank (30L)
15kg
Shipping Dimensions(WxDxH)
Main units
525x610x770mm
Water tank (30L)
520x440x615mm
Introduction about laboratory water purification system
To ensure consistent purity, modern laboratory water purification systems rely on integrated real-time monitoring. Key parameters such as ionic content are tracked through resistivity or conductivity readings, while total organic carbon (TOC) sensors detect any organic impurities. These systems are frequently equipped with data-logging features and network connectivity, allowing for remote supervision and automated alerts. This constant oversight maintains water quality within strict specifications at all times. In the event that purity levels fall below acceptable thresholds, the system can be configured to stop water dispensing or immediately notify personnel. This safeguard prevents the unintended use of compromised water in vital laboratory applications.