Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Type I \/ Type III Laboratory Water Purification System TopPure30A-I","imgUrl":"https:\/\/img.chinax.com\/nimg\/ff\/7b\/eb1d207e1ae7f37fdeb4b51b5037-200x200-1\/type_i_2f_type_iii_laboratory_water_purification_system_toppure30a_i.jpg","attrs":{"Brand Name":"Senova","Model Number":"TopPure30A-I","Certification":"CE","Place of Origin":"China"}}
{"title":"Type I Type II Type III Laboratory Water Purification System MetaPure30N","imgUrl":"https:\/\/img.chinax.com\/nimg\/b6\/dd\/46e438695014027454063523944f-200x200-1\/type_i_type_ii_type_iii_laboratory_water_purification_system_metapure30n.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type III Pure RO Ultra Pure Laboratory Water Purification System HyPure","imgUrl":"https:\/\/img.chinax.com\/nimg\/1f\/86\/9dfe0180c053e7b54275bf8b3c07-200x200-1\/type_i_2f_type_iii_pure_ro_ultra_pure_laboratory_water_purification_system_hypure_30uv_with_point_of_use_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type 1 Ultra Pure Laboratory Water Purification System MaxPure-120PVF with Bio","imgUrl":"https:\/\/img.chinax.com\/nimg\/da\/66\/30f9069e5e4757924ed1ce626f79-200x200-1\/type_1_ultra_pure_laboratory_water_purification_system_maxpure_120pvf_with_bio_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I Type III RO \/ Pure \/ Ultra Pure Laboratory Water Purification System","imgUrl":"https:\/\/img.chinax.com\/nimg\/39\/f8\/64ada20cac10e0cc8f494296af02-200x200-1\/type_i_type_iii_ro_2f_pure_2f_ultra_pure_laboratory_water_purification_system_supure30vf_i.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type III RO \/ Pure \/ Ultra Pure Laboratory Water Purification System","imgUrl":"https:\/\/img.chinax.com\/nimg\/9d\/70\/26aa39e2ca5221058043e1d47260-200x200-1\/type_i_2f_type_iii_ro_2f_pure_2f_ultra_pure_laboratory_water_purification_system_supure30uv_i_with_point_of_use_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Senova","Certification":"CE","Minimum Order Quantity":"1 unit"}}
{"title":"Type I \/ Type 1 Laboratory Water Purification System TopPure120C-BS","imgUrl":"https:\/\/img.chinax.com\/nimg\/9e\/0c\/f63dedf2e60e2f4191571d2085ee-200x200-1\/type_i_2f_type_1_laboratory_water_purification_system_toppure120c_bs.jpg","attrs":{"Brand Name":"Senova","Model Number":"TopPure120C-BS","Certification":"CE","Place of Origin":"China"}}
Type I , Type III Laboratory Water Purification System TopPure30A-I
Features
Our Laboratory Purification System is engineered to deliver consistent, high-purity water for critical applications.
The robust Pretreatment Cartridge employs a compression molding process, effectively eliminating water leakage risks.
Integrated active carbon within pretreatment removes free chlorine from tap water comprehensively.
Built-in PP cotton filtration captures particulates and sediments at the initial stage.
The innovative Reverse Osmosis Module features a low-restriction design, significantly extending its operational lifespan.
Automated forward and backward rinse cycles clean the RO membrane surface, ensuring stable performance and durability.
A dual-wavelength UV lamp, housed in a corrosion-resistant stainless steel chamber, provides powerful purification.
The UV lamp utilizes a high-transmittance synthetic quartz sleeve for maximum efficiency.
Smart activation ensures the UV lamp operates only during ultrapure water production, saving energy.
The Purification Cartridge system is equipped with high-quality, precision-grade ion exchange resin.
A dual-column design vastly increases ion exchange capacity and reduces long-term running costs.
An integrated ultra-purification cartridge targets trace-level ionic and organic contaminants.
A high-quality nuclear-grade resin polishing cartridge delivers the final purity polish.
An active carbon supplement within the cartridge effectively controls organic levels.
The Ultra-Filtration/Micro Filter effectively removes endotoxins, nucleases, and proteins, vital for cell culture.
Filter heads allow easy switching to alternative microfilters for diverse application needs.
A final Point-Of-Use 0.22µm membrane filter ensures contaminant-free dispensing.
Microprocessor Control with PIN-code access protects system settings and protocols.
A fully automatic self-diagnostic system continuously monitors all operational parameters.
Comprehensive Sanitization automates disinfection of the entire fluid pathway.
Module-designed Cartridges enable tool-free, quick-change replacements to minimize downtime.
A high-precision, flow-through resistivity meter with a 0.01 cm⁻¹ cell constant provides unparalleled accuracy.
Automatic Temperature Compensation (0.1°C resolution) delivers meaningful, real-time resistivity readings.
A large, easy-to-read LCD display shows conductivity, resistivity, tank levels, and consumable life.
Contamination-free 30L/60L PE tanks with low extractables include level sensors and overflow protection.
An RS232 port enables seamless network integration and remote monitoring.
An optional strengthened pretreatment module with a 20-inch detergent cartridge handles challenging feed water.
The system boasts a premium touch-screen interface for intuitive operation.
Online TOC monitoring is available to prevent organic breakthrough proactively.
Remote water dispenser options allow convenient water collection and system status checks.
Configuration
TopPure-Series
TopPure30A-I
Pretreatment module
○
High pressure pump
○
Reverse osmosis
○
Dual wavelength UV-lamp
○
Ultra-purification cartridge
○
Ultrafiltration cartridge
○
EDI Module
/
Point-of-use filter
○
Storage tank 30L
○
Air filter net for tank
○
UV-lamp sterilizer for water tank
○
Remote water dispenser with color display
○
TOC monitoring module
/
Specifications
Model
TopPure30A-I
Feed Water Requirement
Source
Tap water
Conductivity*
<2000us/cm
Hardness**
<450ppm as CaCO3
Pressure
0.05~0.5MPa(7-72psi)
Temperature
5~40℃
Purification Water(Class III)
Ionic Rejection
>95%
Bacteria Rejection
>99%
Conductivity
1~20us/cm
Productivity Rate
30L/h
High Quality Purification Water(Type II)
Resistivity At 25℃
/
TOC
/
Dissolved Organic
/
Productivity Rate
/
Ultrapurification Water(Class I)
Resistivity At 25℃
18.2MΩ.cm
Conductivity At 25℃
0.055us/cm
TOC Level**
1~5ppb
Endotoxin(Pyrogens)****
<0.001EU/ml
Particulate(≥0.02µm)
<1pc/ml
Bacteria*
<0.1 cfu/ml
Rnase / Dnase**
Free
Manual dispense flow rate
1.5~2.0L/min
Automatic dispense volume
100~60000ml
Electrical Requirements
Electrical Voltage
110V/220V±10%
Electrical Frequency
50HZ/60HZ
Packing Information
Net Weight
Main units
34kg
Water tank (30L)
7kg
External Dimensions(WxDxH)
Main units
315x525x570mm
Water tank (30L)
380x380x595mm
Shipping weight
Main units
37kg
Water tank (30L)
15kg
Shipping Dimensions(WxDxH)
Main units
525x610x770mm
Water tank (30L)
520x440x615mm
Introduction about laboratory water purification system
The consistent performance of a water purification system depends on a regular and proactive maintenance regimen. Pre-filters and carbon filters require periodic replacement to protect downstream components. RO membranes need monitoring for fouling. DI resins exhaust over time and must be regenerated or replaced. UV lamps lose intensity and should be changed annually. Adhering to the manufacturer’s maintenance schedule is crucial. Neglect can lead to a gradual decline in water quality, increased operating costs, and ultimately system failure, compromising the laboratory’s water supply.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
2010
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Senova Biotech (Shanghai) Co., Ltd. stands as a manufacturer and supplier in the biotechnology equipment sector, specializing in the sophisticated engineering and supply of high-performance freeze-drying and thermostatic equipment. These precision instruments, renowned for their constant temperat...