| Payment Terms | T/T |
| Supply Ability | 100pcs per month |
| Delivery Time | on request |
| Packaging Details | standard carton packing |
| Rated operating distance | 5 mm |
| Safety Integrity Level (SIL) | SIL 2 |
| Mission Time (TM) | 20 a |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| Marine approval | DNVGL TAA00001A5 |
| Connection type | cable |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Degree of protection | IP66 / IP68 |
| Brand Name | P+F |
| Model Number | NJ5-18GK-N |
| Certification | CE |
| Place of Origin | Germany |
View Detail Information
Explore similar products
P+F KFD2-SR2-Ex1.W Switch Amplifier SIL 2 35mA 10Hz
P+F LFL2-BK-U-PUR5-EMS Float Switch 250VAC IP68
P+F RL28-8-H-2000-IR Background Suppression Sensor 880nm IP67
P+F Z787 Zener Barrier 50mA DC Positive Polarity
Product Specification
| Payment Terms | T/T | Supply Ability | 100pcs per month |
| Delivery Time | on request | Packaging Details | standard carton packing |
| Rated operating distance | 5 mm | Safety Integrity Level (SIL) | SIL 2 |
| Mission Time (TM) | 20 a | Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| Marine approval | DNVGL TAA00001A5 | Connection type | cable |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | Degree of protection | IP66 / IP68 |
| Brand Name | P+F | Model Number | NJ5-18GK-N |
| Certification | CE | Place of Origin | Germany |
| High Light | P&F Sensors NJ5-18GK-N ,NJ5-18GK-N Inductive Sensor ,Inductive Sensor 5mm | ||
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X
Technical Data
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 5 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 4.05 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | 1 ... 10 typ. 5 % | |
| Current consumption |
| |
|
| Measuring plate not detected | min. 3 mA |
|
| Measuring plate detected | ≤ 1 mA |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| MTTFd | 4566 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity |
| |
|
| NAMUR | EN 60947-5-6:2000 |
|
| Standards | EN 60947-5-2:2007 |
| Approvals and certificates | ||
| IECEx approval |
| |
|
| Equipment protection level Gb | IECEx PTB 11.0037X |
|
| Equipment protection level Da | IECEx PTB 11.0037X |
|
| Equipment protection level Mb | IECEx PTB 11.0037X |
| ATEX approval |
| |
|
| Equipment protection level Gb | PTB 00 ATEX 2048 X |
|
| Equipment protection level Da | PTB 00 ATEX 2048 X |
| UL approval | cULus Listed, General Purpose | |
| CCC approval |
| |
|
| Hazardous Location | 2020322315002255 |
| NEPSI approval |
| |
|
| NEPSI certificate | GYJ16.1393X |
| CML approval | on request | |
| ANZEx | 18.3018X | |
| KCC approval |
| |
|
| Hazardous Location | 19-AV4BO-0227 |
| Marine approval | DNVGL TAA00001A5 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable | |
| Housing material | PBT/PPS | |
| Sensing face | PBT | |
| Degree of protection | IP66 / IP68 | |
| Cable |
| |
|
| Cable diameter | 6 mm ± 0.2 mm |
|
| Bending radius | > 10 x cable diameter |
|
| Material | PVC |
|
| Core cross section | 0.75 mm2 |
|
| Length | 2 m |
| Dimensions |
| |
|
| Length | 39 mm |
|
| Diameter | 18 mm |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
Related Models:
| KCD2-SCD-EX1 | KFU8-UFT |
| KCD2-STC-EX1.20 | K-HM26-2M-261533 |
| KFD2-SR2-Ex1.W.LB | NBB15-U1-E2 |
| KFD2-SR2-2.W.SM | NBB1,5-5GM25-E2 |
| KFD2-SR2-Ex2.W.SM | NBB1,5-5GM25-E2-V3 |
| KFD2-SR2-Ex2.2S | NBB1,5-F79-E0 |
| KFD2-SR2-2.2S | NBB1,5-F79-E2 |
| KFA6-DWB-EX1.D | NBB15-U1-Z2 |
| KFA6-SR2-Ex2.W | NBB5-18GM50-E2-V1 |
| KFA6-SR-2.3L.FA | NBB15-30GM30-E2-V1 |
| KFA6-ER-1.5 | NBB15-30GM50-A2-V1 |
| NBB15-30GM50-E2 | |
| KFA6-ER-1.W.LB | NBB15-30GM50-E2-M |
| KFA6-ER-2.W.LB | NBB15-30GM50-E2-V1 |
| NBB15-30GM50-E2-V1-M | |
| KFA6-SR-2.3L.FA | NBB8-18GM30-E2 |
| KFA6-STR-1.24.4 | NBB8-18GM30-E2-V1 |
| KFD0-CS-Ex1.50P | NBB8-18GM60-A2-V1 |
| KFD2-SH-Ex1.T.OP | NJ4-12GK-SN |
| KFD2-SL2-EX2.B | NJ5-18GK-N |
| KFD2-SR2-EX1.W | NJ5-18GK-N-150 |
| KFD2-SR2-Ex2.W | NJ5-18GM-N |
| KFD2-STC5-1.2O | NJ8-18GK-N |
| KFD2-STC5-Ex1 | RD0-FB-EX4 |
| KFD2-STC5-Ex1.H | RD0-TI-Ex8.FF.* |
| HIC2031 | Z787.F |
![]()
![]()
![]()
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1... .gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1...
Get in touch with us
Leave a Message, we will call you back quickly!