| Payment Terms | T/T |
| Supply Ability | 100pcs per month |
| Delivery Time | on request |
| Packaging Details | standard carton packing |
| Number of channels | One |
| Location of RTD | Zone 0, IIC, T4 hazardous area Div 1, Group A hazardous location |
| Resistance range | 10Ω to 400Ω |
| RTD excitation current | 200µA nominal |
| Output configuration | 2, 3 or 4 wires (independent of mode selected for hazardous-area terminals |
| Output range | 10Ω to 400Ω (from a 100µA to 5mA source) |
| Brand Name | MTL |
| Model Number | MTL5082 |
| Certification | CE |
| Place of Origin | India |
View Detail Information
Explore similar products
MTL HCU16 HART Connection Unit Safety Barrier 0.5KG England
MTL Safety Barrier TP48-3-N-NDI Surge Protection 20kA EN 61643-21
MTL5531 Vibration Transducer Interface 2-Wire 3.3mA
MTL5511 NAMUR Proximity Detector Interface 24V 25mA
Product Specification
| Payment Terms | T/T | Supply Ability | 100pcs per month |
| Delivery Time | on request | Packaging Details | standard carton packing |
| Number of channels | One | Location of RTD | Zone 0, IIC, T4 hazardous area Div 1, Group A hazardous location |
| Resistance range | 10Ω to 400Ω | RTD excitation current | 200µA nominal |
| Output configuration | 2, 3 or 4 wires (independent of mode selected for hazardous-area terminals | Output range | 10Ω to 400Ω (from a 100µA to 5mA source) |
| Brand Name | MTL | Model Number | MTL5082 |
| Certification | CE | Place of Origin | India |
| High Light | MTL5082 Isolated Safety Barrier ,MTL Isolated Safety Barrier | ||
The MTL5082 connects to a 2-, 3-, or 4-wire resistance temperature device (RTD) or other resistance located in a hazardous area, isolates
it and repeats the resistance to a monitoring system in the safe area. The module is intended typically (but not exclusively) for use with Pt100
3-wire RTDs. Switches located on top of the module allow selection of 2-, 3-, or 4-wire RTD connection. The MTL5082 should be considered
as an alternative, non-configurable MTL5074, for use in RTD applications where a resistance input is preferred or needed instead of 4/20mA.
The design is notable for its ease of use and repeatability. The number of wires which can be connected on the safe-area side of the unit is independent of the number of wires which can be connected on the hazardous-area side. The module drives upscale in the case of open-circuit detection.
| MTL5521 | MTL4546Y | MTL5501-SR | MTL5510 |
| MTL5522 | MTL4549Y | MTL5511 | MTL5513 |
| MTL5531 | MTL4573 | MTL5514D | MTL5516C |
| MTL5532 | MTL4575 | MTL5521/5521-T | MTL5522 |
| MTL5541 | MTL4646Y | MTL5523V | MTL5523VL |
| MTL5541S | MTL4850 | MTL5525 | MTL5526 |
| MTL5544 | MTL4851 | MTL5532 | MTL5533 |
| MTL5544D | MTL4852 | MTL5541/MTL5541-T | MTL5541A |
| MTL5546 | MTL5018 | MTL5541S/5541S-T | MTL5544 |
| MTL5546Y | MTL5032 | MTL5544AS | MTL5544S |
| MTL5561 | MTL5042 | MTL5573 | MTL5561 |
| MTL5573 | MTL5044 | MTL5546 | MTL5546Y/5546Y-T |
| MTL5575 | MTL5049 | MTL5575 | MTL5576-RTD |
| MTL5582B | MTL5511 | MTL5581 | MTL5582/5582B |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade. We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good co... SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade. We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good co...
Get in touch with us
Leave a Message, we will call you back quickly!