Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | 12-16weeks |
Packaging Details | standard carton packing |
Sensitivity | 10.2 mV/m/s2 (100 mV/g) ±5%. |
Acceleration range | 490 m/s2 (50 g) peak overall acceleration within the 10 Hz to 15 kHz frequency span. Vibration at frequencies above 15 kHz, especially at the transducers resonance will significantly decrease this range. |
Amplitude Linearity | ±1% to 490 m/ s2 (50 g) peak. |
Broadband Noise Floor (10 Hz to 15 kHz) | 0.039 m/s2 (0.004 g) rms. |
Frequency Response | 10 Hz to 15 kHz (600 cpm to 900,000 cpm) ±3dB; 30 Hz to 10 kHz (1800 cpm to 600,000 cpm) ±10% |
Temperature Sensitivity | -11% to +3% typical over the operating temperature range. |
Brand Name | Bently Nevada |
Model Number | 330400-01-CN |
Certification | CE |
Place of Origin | USA |
View Detail Information
Explore similar products
Bently Nevada 2300/20-00 Vibration Monitor 18-36Vdc
21000 Bently Nevada Proximity Probe Housing Assembly Aluminum
3.94 mV/mm/s Bently Nevada 190501 Velomitor CT Vibration Transducer
20kHz Bently Nevada 200150 200155 200157 Vibration Accelerometer
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | 12-16weeks | Packaging Details | standard carton packing |
Sensitivity | 10.2 mV/m/s2 (100 mV/g) ±5%. | Acceleration range | 490 m/s2 (50 g) peak overall acceleration within the 10 Hz to 15 kHz frequency span. Vibration at frequencies above 15 kHz, especially at the transducers resonance will significantly decrease this range. |
Amplitude Linearity | ±1% to 490 m/ s2 (50 g) peak. | Broadband Noise Floor (10 Hz to 15 kHz) | 0.039 m/s2 (0.004 g) rms. |
Frequency Response | 10 Hz to 15 kHz (600 cpm to 900,000 cpm) ±3dB; 30 Hz to 10 kHz (1800 cpm to 600,000 cpm) ±10% | Temperature Sensitivity | -11% to +3% typical over the operating temperature range. |
Brand Name | Bently Nevada | Model Number | 330400-01-CN |
Certification | CE | Place of Origin | USA |
High Light | bently nevada accelerometer 100 mV/g ,bently nevada 330400 accelerometer ,330400 accelerometer 330400-01-CN |
These accelerometers are intended for critical machinery applications where casing acceleration measurements are required, such as gear mesh monitoring. The 330400 is designed to address the requirements of American Petroleum Institute Standard 670 for accelerometers. It provides an amplitude range of 50 g peak and a sensitivity of 100 mV/g. The 330425 is identical except it provides a larger amplitude range (75 g peak) and a sensitivity of 25 mV/g.
330400 Accelerometer
330400-AA-BB
A: Mounting Thread Option | |
01 | ¼-28 UNF integral stud |
02 | M8 X 1 integral stud |
B: Agency Approval Option | |
00 | None |
05 | Multiple approvals (CSA, ATEX, IECEx,) |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1... .gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1...
Get in touch with us
Leave a Message, we will call you back quickly!