| Payment Terms | T/T |
| Supply Ability | 100pcs per month |
| Delivery Time | 8-12 weeks |
| Packaging Details | Original packaging |
| Measuring principle | Conductive |
| Supply voltage | 10…30 V DC |
| Ambient temperature | -40 ... 70°C (-40 ... 158°F) |
| Process temperature | -20 ... 100°C (-4 ... 212°F) |
| Process pressure | 0 to 25bar abs (0 to 362.5psi abs) |
| Wetted parts | Sensor: 316L, Sensor isolation: PEEK |
| Brand Name | Endress+Hauser |
View Detail Information
Explore similar products
1Channel Endress Hauser Transmitter Liquiline CM14 For PH ORP Sensors
Endress Hauser Oxymax COS41 Dissolved Oxygen Sensor 0.05-20mg/l
Endress Hauser Prosonic FDU95 Ultrasonic Level Sensor for Bulk Materials
Endress+Hauser FMR60 Radar Level Sensor with 80GHz Drip-off Antenna
Product Specification
| Payment Terms | T/T | Supply Ability | 100pcs per month |
| Delivery Time | 8-12 weeks | Packaging Details | Original packaging |
| Measuring principle | Conductive | Supply voltage | 10…30 V DC |
| Ambient temperature | -40 ... 70°C (-40 ... 158°F) | Process temperature | -20 ... 100°C (-4 ... 212°F) |
| Process pressure | 0 to 25bar abs (0 to 362.5psi abs) | Wetted parts | Sensor: 316L, Sensor isolation: PEEK |
| Brand Name | Endress+Hauser |
The Liquipoint FTW33 is developed for the food industry and meets all international hygiene requirements. The device also fits perfectly for applications in all industries.
Designed for use in pasty and sticky media and media with heavy build-up. Suitable for pipes and in storage, mixing and process vessels with or without an agitator.
| Temperature Range | -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour |
|---|---|
| Pressure Range | 0 to 25 bar abs (0 to 362.5 psi abs) |
| Hygienic Certificates | Included |
| Measuring Principle | Conductive |
|---|---|
| Characteristic / Application | Compact point level switch for using in pipes and in storage, mixing and process vessels with or without an agitator, for water based or oil based media, with active build up compensation, flush mounting |
| Specialities | CIP and SIP suitable Conductive foam is detectable or can be switched off |
| Supply / Communication | 10…30 V DC |
| Ambient Temperature | -40 ... 70°C (-40 ... 158°F) |
| Process Temperature | Standard: -20 ... 100°C Cleaning: -20 ... 150°C for 1h (-4 ... 302°F for 1h) |
| Process Pressure / Max. Overpressure Limit | Vacuum ... 25 bar (Vacuum ... 362.5 psi) |
| Main Wetted Parts | Sensor: 316L Sensor isolation: PEEK |
| Process Connection | Thread G1, G1/2, G3/4, M24 |
| Process Connection Hygienic | Clamp ISO 2852 1 to 1 1/2", 2", DIN11851 Pipe union |
| Communication | DC PNP |
| Certificates / Approvals | CSA C/US |
|---|---|
| Design Approvals | EN 10204-3.1 |
| Hygienic Approvals | 3A, EHEDG |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1... .gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1...
Get in touch with us
Leave a Message, we will call you back quickly!