Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Durable non indicating pressure transmitter Autonics TPS20 G25F8 00 with fluoro","imgUrl":"https:\/\/img.chinax.com\/nimg\/d1\/91\/bde01250e673d4e4c8aa1310eb9c-200x200-1\/durable_non_indicating_pressure_transmitter_autonics_tps20_g25f8_00_with_fluoro.jpg","attrs":{"Pressure range":"0Kpa~6.8647bar","Description":"0Kpa~6.8647bar Pressure Sensors, Transducers RoHS","Mfr. Part #":"TPS20-G25F8-00","Model Number":"TPS20-G25F8-00"}}
{"title":"HAOBANG HI TECH HBP5023A502DBS8 2 Dual Port Differential Pressure Sensor with","imgUrl":"https:\/\/img.chinax.com\/nimg\/36\/a3\/734915541b3c4dcfb13a537b13a1-200x200-1\/haobang_hi_tech_hbp5023a502dbs8_2_dual_port_differential_pressure_sensor_with_and_high_accuracy_output.jpg","attrs":{"Description":"SOP-8 Pressure Sensors, Transducers RoHS","Mfr. Part #":"HBP5023A502DBS8-2","Model Number":"HBP5023A502DBS8-2","Package":"SOP-8"}}
{"title":"HAOBANG HI TECH HBP5033D142DPD6 2 Digital Differential Pressure Sensor with and","imgUrl":"https:\/\/img.chinax.com\/nimg\/5d\/9a\/f8f12bc81031149af5f96f046d8f-200x200-1\/haobang_hi_tech_hbp5033d142dpd6_2_digital_differential_pressure_sensor_with_and_high_linearity_performance.jpg","attrs":{"Description":"DIP-6 Pressure Sensors, Transducers RoHS","Mfr. Part #":"HBP5033D142DPD6-2","Model Number":"HBP5033D142DPD6-2","Package":"DIP-6"}}
{"title":"Compact and Accurate HAOBANG HI-TECH HBP5013D202DBS8-2 Pressure Sensor with Dual","imgUrl":"https:\/\/img.chinax.com\/nimg\/5d\/9a\/f8f12bc81031149af5f96f046d8f-200x200-1\/compact_and_accurate_haobang_hi_tech_hbp5013d202dbs8_2_pressure_sensor_with_dual_air_nozzle_sop8_package.jpg","attrs":{"Description":"SOP-8 Pressure Sensors, Transducers RoHS","Mfr. Part #":"HBP5013D202DBS8-2","Model Number":"HBP5013D202DBS8-2","Package":"SOP-8"}}
{"title":"Compact pressure sensor module HAOBANG HI-TECH HBP1101A040GBS6-2 for non","imgUrl":"https:\/\/img.chinax.com\/nimg\/36\/a3\/734915541b3c4dcfb13a537b13a1-200x200-1\/compact_pressure_sensor_module_haobang_hi_tech_hbp1101a040gbs6_2_for_non_corrosive_gas_differential_pressure_measurement.jpg","attrs":{"Module":"Yes","Description":"SOP-6 Pressure Sensors, Transducers RoHS","Mfr. Part #":"HBP1101A040GBS6-2","Model Number":"HBP1101A040GBS6-2"}}
{"title":"Industrial automation and HVAC differential pressure sensor HAOBANG HI-TECH","imgUrl":"https:\/\/img.chinax.com\/nimg\/36\/a3\/734915541b3c4dcfb13a537b13a1-200x200-1\/industrial_automation_and_hvac_differential_pressure_sensor_haobang_hi_tech_hbp5013a501dbs8_2_with_consumption.jpg","attrs":{"Description":"SOP-8 Pressure Sensors, Transducers RoHS","Mfr. Part #":"HBP5013A501DBS8-2","Model Number":"HBP5013A501DBS8-2","Package":"SOP-8"}}
G-67 TPS20 Series Non-indicating Pressure Transmitters
The TPS20 Series Non-indicating Pressure Transmitters offer excellent corrosion resistance with a stainless steel housing and high accuracy of 0.3% F.S. Designed for versatility, they feature various connection methods, including head type, DIN connector type, and connector cable type. User-friendly functions such as built-in zero-point and span adjustment are available for the head type. These transmitters are suitable for measuring liquid, gas, and oil, excluding corrosive environments for the stainless steel type 316. They are designed for industrial applications requiring reliable pressure measurement.
0 to 0.2 to 350kgf/cm (Gauge pressure) 0 to 1.0 to 35kgf/cm (Absolute pressure) -760mmHg to 0 to 35kgf/cm (Compound pressure)
Max. Pressure Range
300% of max. span
Measured Materials
Liquid, gas, oil (except corrosive environment of stainless steel type 316)
Power Supply
15-35VDC
Permissible Voltage Range
90 to 110% of rated voltage
Current Consumption
Max. 50mA
Response Time
Max. 100ms
Current Output
DC4-20mA
Linearity
0.3% F.S. (-10 to 50), 0.5% F.S. (50 to 70)
Hysteresis
0.3% F.S.
Temp. Zero Shift
0.03% F.S.
Temp. Span Shift
0.03% F.S. (at 25)
Load Resistance
Max. 600
Insulation Resistance
Over 100M (at 500VDC megger)
Dielectric Strength
500VAC 50/60Hz for 1 minute
Vibration
1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock
95m/s
Tightening Torque
Industrial plug over 5N
Pressure Port
G3/8 (standard), R3/8, R1/2
Ambient Temperature
-10 to 70 (operation), -10 to 70 (storage)
Ambient Humidity
5 to 95% RH (operation), 5 to 95% RH (storage)
Weight
Approx. 350g (approx. 320g for unit only, head type)
Connection Types
Head type, DIN connector type, Connector cable type
Connection Cable Models (Sold Separately)
CID3-2, CID3-5, CLD3-2, CLD3-5
Environmental Conditions
Indoor/Outdoor (within rated conditions), Altitude max. 2,000 m, Pollution Degree 2, Installation Category II
Connection Diagrams
Head type
DIN connector type
Connector cable type
Connection Cable Dimensions
CLD3-2 / CLD3-5
Model
L (m)
Material
CLD3-2
2
PVC
CLD3-5
5
PVC
CID3-2 / CID3-5
Model
L (m)
Material
CID3-2
2
PVC
CID3-5
5
PVC
Wiring Information
Connection Type
Pin
Function
Head type
+
+V (15-35VDC)
-
GND
+
Output (DC4-20mA)
-
Load (600)
DIN connector type
1
+
2
-
4
F.G. (Frame Ground)
Connector cable type
+
+V (15-35VDC)
-
GND
Note: In case of head type, remove the top cover.
Troubleshooting
No outputs: Check power supply, polarity (+, -) when wiring, and connection part.
Abnormally fluctuating output: Check power supply, supplied pressure, and pressure line.
Out of zero point output value: Check power supply, load resistive value of current output type for a receiver (over 600), measuring point and transmission distance. Ensure line resistance is below 600.
Cautions during Use
Follow instructions in 'Safety Considerations' in the instruction manual.
15-35VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
When installing the unit on a pipeline, use the hexagon part of connections, not the unit itself, with a pipe wrench.
Do not use the unit with strong vibrations.
Store the unit in a place without moisture, dust, and vibration.
This product does not require repair as it has no drive part at the sensing part.
For maintenance (once a year): Check for broken status of the outside, pressure slot cleanliness, and corrosion state. Short each terminal and check insulation resistance between the case and power.
When removing a sensor for maintenance, replace the O-ring and ensure the diaphragm part is not damaged.
Install a switch or circuit breaker for supplying or cutting off power nearby for convenient control.
The unit cannot be repaired due to its disassembled structure.
The unit is fixed with bolts and nuts on both sides of the case. Do not apply excessive load (approx. 300kg/cm), as it may cause damage.
Changsha Purple Horn E-Commerce Co., Ltd.. is a professional company focus on integrated circuit ic business. Purple Horn will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining and manufacture.
Founded in 2009, Our compa... Changsha Purple Horn E-Commerce Co., Ltd.. is a professional company focus on integrated circuit ic business. Purple Horn will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining and manufacture.