Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"Industrial Particulate Monitoring Solution Dwyer PMT2-20-A-U2 with 316L","imgUrl":"https:\/\/img.chinax.com\/nimg\/f3\/20\/8f0b298dfef6e8022f30f12496a6-200x200-1\/industrial_particulate_monitoring_solution_dwyer_pmt2_20_a_u2_with_316l_stainless_steel_construction.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-20-A-U2","Model Number":"PMT2-20-A-U2"}}
{"title":"4-20 mA output particulate transmitter Dwyer PMT2-15-A-A2 for bin vent and","imgUrl":"https:\/\/img.chinax.com\/nimg\/bf\/33\/140111d18a9261b04e2a785247ba-200x200-1\/4_20_ma_output_particulate_transmitter_dwyer_pmt2_15_a_a2_for_bin_vent_and_emission_monitoring_applications.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-15-A-A2","Model Number":"PMT2-15-A-A2"}}
{"title":"4-20 mA Signal Particulate Transmitter Dwyer PMT2-03-A-U2 for Baghouse Leak and","imgUrl":"https:\/\/img.chinax.com\/nimg\/4f\/a3\/362c88663e8d073ca23766f16aad-200x200-1\/4_20_ma_signal_particulate_transmitter_dwyer_pmt2_03_a_u2_for_baghouse_leak_and_filter_wear_detection.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-03-A-U2","Model Number":"PMT2-03-A-U2"}}
{"title":"Dust collector particulate transmitter Dwyer PMT2-05-A-U2 with PTFE coated probe","imgUrl":"https:\/\/img.chinax.com\/nimg\/d1\/8c\/b7e40612f074febf1cbce34098c3-200x200-1\/dust_collector_particulate_transmitter_dwyer_pmt2_05_a_u2_with_ptfe_coated_probe_and_calibration.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-05-A-U2","Model Number":"PMT2-05-A-U2"}}
{"title":"particulate sensing device Dwyer PMT2-10-A-A2-M20 with electrostatic induction","imgUrl":"https:\/\/img.chinax.com\/nimg\/61\/f5\/5ba8379418bff852555263688ed3-200x200-1\/particulate_sensing_device_dwyer_pmt2_10_a_a2_m20_with_electrostatic_induction_technology_and_4_20_ma_output.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-10-A-A2-M20","Model Number":"PMT2-10-A-A2-M20"}}
{"title":"Dust emissions particulate transmitter Dwyer PMT2-10-B-A2 with 4-20 milliamp","imgUrl":"https:\/\/img.chinax.com\/nimg\/46\/bd\/6dd902d43a7a1a9fb7338e627515-200x200-1\/dust_emissions_particulate_transmitter_dwyer_pmt2_10_b_a2_with_4_20_milliamp_signal_and_range_test_switches.jpg","attrs":{"Description":"Particulate Matter (PM) Transmitters ","Mfr. Part #":"PMT2-10-B-A2","Model Number":"PMT2-10-B-A2"}}
The PMT2 Series Particulate Transmitter is designed to measure particulate levels in dust collector emissions. Utilizing DC-coupled electrostatic induction sensing technology, it monitors the pA current generated by particulates passing near the probe. The transmitter provides a 4-20 mA signal proportional to the particulate level and offers 6 sensitivity ranges for user selection. Features include digital damping, a non-stick probe for accurate readings in challenging environments, and remote zero calibration for reduced maintenance. It is suitable for PLC and control panel integration with a simple 2-wire installation.
Features & Benefits
Simple 2-wire installation for PLC and control panels.
Non-stick PTFE coated probe prevents erroneous readings from moisture and conductive dust, condensation, and dust buildup.
*Not available with ATEX or IECEx. Devices without suffix A2 do not comply with 2014/34/EU (ATEX) directive and are not suitable for use in potentially explosive atmospheres in the EU. These devices may carry CE marking for other EU directives.
Specifications:
Media: Air and compatible gases, conductive or non-conductive particles of any type.
Wetted Materials: 316L SS, Silicone, and PTFE.
Housing: Powder coated aluminum.
Accuracy: 5% of reading.
Particle Size: 0.3 micron and larger.
Detection Range: 5 to 5000 pA (6 selectable ranges).
Temperature Limits: Ambient: -40 to 63C (-40 to 145F); Process: -40 to 120C (-40 to 248F).
Pressure Limit: 30 psi (2 bar).
Output Signal: 4-20 mA.
Power Requirement: 12-28 VDC.
Electrical Connections: Two 1/2 Female NPT or two M20 (for suffix A2 only).
Terminal Block: Removable (16 to 20 AWG wire).
Probe Length: See model table.
Housing Rating: UL Type 4 (IP66); ATEX/IECEx IP65.
Mounting Orientation: Any.
Averaging Time: 1 to 360 seconds (10 selectable options).
Changsha Purple Horn E-Commerce Co., Ltd.. is a professional company focus on integrated circuit ic business. Purple Horn will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining and manufacture.
Founded in 2009, Our compa... Changsha Purple Horn E-Commerce Co., Ltd.. is a professional company focus on integrated circuit ic business. Purple Horn will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining and manufacture.
Founded in 2009, Our compa...