Payment Terms | T/T,PAYONEER |
Supply Ability | 30EA,8weeks |
Delivery Time | 8 WEEKS |
Packaging Details | Does not supply |
BRAND | EMERSON ROSEMOUNT |
MODEL | 3051CFCDCS060N065032AA1WCE5M5 |
CATEGORY | Compact Flow Meter |
SUPPLY | 4–20 mA |
Measurement type | Differential pressure |
Delivery time | 8 weeks |
Weight | Does not supply |
Brand Name | ROSEMOUNT |
Model Number | 3051CFCDCS060N065032AA1WCE5M5 |
Place of Origin | Singapore |
Certification | Does not supply |
View Detail Information
Explore similar products
STD924-E1H-00000-H6,SM,ZS,(CC),TG,S2,MB,F1,W2,1C+XXXX Differential Pressure
3051L2AA0D21AAF1 Rosemount 3051 Flow Meter Transmitter Rosemount Level
3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter
3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box
Product Specification
Payment Terms | T/T,PAYONEER | Supply Ability | 30EA,8weeks |
Delivery Time | 8 WEEKS | Packaging Details | Does not supply |
BRAND | EMERSON ROSEMOUNT | MODEL | 3051CFCDCS060N065032AA1WCE5M5 |
CATEGORY | Compact Flow Meter | SUPPLY | 4–20 mA |
Measurement type | Differential pressure | Delivery time | 8 weeks |
Weight | Does not supply | Brand Name | ROSEMOUNT |
Model Number | 3051CFCDCS060N065032AA1WCE5M5 | Place of Origin | Singapore |
Certification | Does not supply | ||
High Light | Compact Pressure Temperature Transmitter ,20mA Pressure Temperature Transmitter ,rosemount 3051CFC 4mA |
3051CFCDCS060N065032AA1WCE5M5 Compact Flow Meter Rosemount 3051CFC
Product Information Of: 3051CFCDCS060N065032AA1WCE5M5
Brand | EMERSON ROSEMOUNT |
Model | 3051CFCDCS060N065032AA1WCE5M5 |
SUPPLY | 0.65 beta ratio |
SIZE | Does not supply |
Weight | Does not supply |
Rosemount 3051CFC Compact Flow Meters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact Annubar or minimize straight run requirements with the Conditioning Orifice.
■Up to 1.8 percent of flow rate accuracy.
■Available in ½- to 12-in. (15 to 300 mm) line sizes.
■Fully assembled and leak tested for out-of-the-box installation.
■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons (option code M4).
More options :
3051CG2A22A1AB4M5E5
3051CG3A22A1AB4M5E5
3051CG4A22A1AB4M5E5
3051CG5A22A1AB4M5E5
3051CG1A22A1AB4M5I5
3051CG2A22A1AB4M5I5
3051CG3A22A1AB4M5I5
3051CG4A22A1AB4M5I5
3051CD0A02A1AB1H2L4M5
3051CD1A02A1AB1H2L4M5
3051CD2A02A1AB1H2L4M5
3051CD3A02A1AB1H2L4M5
3051CD4A02A1AB1H2L4M5
3051CD5A02A1AB1H2L4M5
3051CD0A02A1AB3H2L4M5
3051CD1A02A1AB3H2L4M5
3051CD2A02A1AB3H2L4M5
3051CD3A02A1AB3H2L4M5
3051CG5A22A1AB4M5I5
MR-J2S-70B-PY135U504
MR-J2S-40B-PY135U504
MR-J2S-70B-FH168V003
MR-J2S-70B-S014
MR-J2S-70B-EE085
MR-J2S-100B-EE085
MR-J2S-70B-S041U737
MR-J2S-200A-PM070
MR-J2S-200A-S011
MR-J2S-200B-PY096
MR-J2S-200B-PY179
MR-J2S-200B-QR141U633
MR-J2S-200A-EJ220
MR-J2S-200A-EJ012
MR-J2S-200B-T004
Rosemount 3051CFA Annubar Flow Meter Information:
Model | Product description | |
3051CFC | Compact flow meter | |
Measurement type | ||
D | Differential pressure | ★ |
Primary element technology | ||
A | Annubar averaging pitot tube | ★ |
C | Conditioning orifice plate | ★ |
P | Orifice plate | ★ |
Material type | ||
S | 316 SST | ★ |
Line size | ||
005(1) | ½-in. (15 mm) | ★ |
010(1) | 1-in. (25 mm) | ★ |
015(1) | 1½-in. (40 mm) | ★ |
020 | 2-in. (50 mm) | ★ |
030 | 3-in. (80 mm) | ★ |
040 | 4-in. (100 mm) | ★ |
060 | 6-in. (150 mm) | ★ |
080 | 8-in. (200 mm) | ★ |
100(2) | 10-in. (250 mm) | ★ | |
120(2) | 12-in. (300 mm) | ★ | |
Primary element type | |||
N000 | Rosemount Annubar sensor size 1 | ★ | |
N040 | 0.40 beta ratio | ★ | |
N050 | 0.50 beta ratio | ||
N065(3) | 0.65 beta ratio | ★ | |
Temperature measurement | |||
0 | No temperature sensor | ★ | |
R | Remote thermowell and RTD | ||
Transmitter connection platform | |||
3 | Direct-mount | ★ | |
7 | Remote-mount, NPT connections | ★ | |
Differential pressure range | |||
1 | 0 to 25 in H2O (0 to 62,16 mbar) | ★ | |
2 | 0 to 250 in H2O (0 to 621,60 mbar) | ★ | |
3 | 0 to 1000 in H2O (0 to 2,48 bar) | ★ | |
Transmitter output | |||
A(4) | 4–20 mA with digital signal based on HART® Protocol | ★ | |
F | FOUNDATION™ Fieldbus Protocol | ★ | |
W (5) | PROFIBUS® PA Protocol | ★ | |
X(6) | Wireless (requires wireless options and engineered polymer housing) | ★ | |
M(7) | Low-power 1–5 Vdc with digital signal based on HART Protocol | ||
Transmitter housing material | Conduit entry size | ||
A | Aluminum | ½–14 NPT | ★ |
B | Aluminum | M20 x 1.5 | ★ |
E | Aluminum, ultra low copper | ½–14 NPT | |
F | Aluminum, ultra low copper | M20 x 1.5 | |
J | SST | ½–14 NPT | ★ |
K | SST | M20 x 1.5 | ★ |
P(8) | Engineered polymer | No conduit entries | ★ |
D(9) | Aluminum | G½ | |
M(9) | SST | G½ | |
Transmitter performance class | |||
1 | Up to ±1.65% flow rate accuracy, 8:1 flow turndown, 5-year stability | ★ |
Wireless options (requires wireless output code X and Engineered Polymer Housing code P) | ||
Wireless transmit rate, operating frequency, and protocol | ||
WA3 | User configurable transmit rate, 2.4 GHz WirelessHART | ★ |
Antenna and SmartPower | ||
WP5 | Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) | ★ |
Extended product warranty | ||
WR3 | 3-year limited warranty | ★ |
WR5 | 5-year limited warranty | ★ |
Installation accessories | ||
AB | ANSI alignment ring (Class 150) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) | ★ |
AC | ANSI alignment ring (Class 300) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) | ★ |
AD | ANSI alignment ring (Class 600) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) | ★ |
DG | DIN alignment ring (PN16) | ★ |
DH | DIN alignment ring (PN40) | ★ |
DJ | DIN alignment ring (PN100) | ★ |
JB | JIS alignment ring (10K) | |
JR | JIS alignment ring (20K) | |
JS | JIS alignment ring (40K) | |
Remote adapters | ||
FE | Flange adapters 316 SST (½-in NPT) | ★ |
High temperature application | ||
HT | Graphite valve packing (Tmax = 850 °F) | |
Flow calibration(10) | ||
WC | Flow calibration, 3 pt, conditioning orifice option C (all pipe schedules) | |
WD(11) | Flow calibration, 10 pt, conditioning option C (all schedules), Annubar option A (schedule 40) | |
Pressure testing | ||
P1 | Hydrostatic testing with certificate | |
Special cleaning | ||
P2(12) | Cleaning for special services | |
PA | Cleaning per ASTM G93 level D (section 11.4) | |
Special inspection | ||
QC1 | Visual & dimensional inspection with certificate | ★ |
QC7 | Inspection and performance certificate | ★ |
Transmitter calibration certification | ||
Q4 | Calibration certificate for transmitter | ★ |
Quality certification for safety(13) | ||
QS | Prior-use certificate of FMEDA data | ★ |
QT | Safety certified to IEC 61508 with certificate of FMEDA | ★ |
Material traceability certification | ||
Q8 | Material Traceability Certification per EN 10204:2004 3.1 | ★ |
Code conformance | ||
J2 | ANSI/ASME B31.1 | |
J3 | ANSI/ASME B31.3 | |
J4 | ANSI/ASME B31.8 | |
Materials conformance(14) | ||
J5 | NACE MR-0175/ISO 15156 | |
Country certification | ||
J1 | Canadian Registration | |
Product certifications | ||
E8 | ATEX Flameproof, Dust | ★ |
I1(15) | ATEX Intrinsic Safety and Dust | ★ |
IA | ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
N1 | ATEX Type n and Dust | ★ |
K8 | ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1, and N1) | ★ |
E5 | FM Explosion-proof, Dust Ignition-proof | ★ |
I5(16) | FM Intrinsically Safe, Nonincendive | ★ |
IE | FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
K5 | FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5) | ★ |
C6 | CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 | ★ |
I6(8) | CSA Intrinsically Safe | ★ |
K6 | CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) | ★ |
E7 | IECEx Flameproof, Dust Ignition-proof | ★ |
I7 | IECEx Intrinsic Safety | ★ |
N7 | IECEx Type n | ★ |
K7 | IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) | ★ |
E2 | INMETRO Flameproof | ★ |
I2 | INMETRO Intrinsic Safety | ★ |
IB | INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
K2 | INMETRO Flameproof, Intrinsic Safety | ★ |
E3 | China Flameproof | ★ |
I3 | China Intrinsic Safety | ★ |
KB | FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) | ★ |
KD | CSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8) | ★ |
Sensor fill fluid and O-ring options | ||
L1(17) | Inert sensor fill fluid | ★ |
L2 | Graphite-filled (PTFE) O-ring | ★ |
LA(17) | Inert sensor fill fluid and graphite-filled (PTFE) O-ring | ★ |
Shipboard approvals(17) | ||
SBS | American Bureau of Shipping | ★ |
SLL(18) | Lloyds Register (LR) | |
Display and interface options | ||
M4(19) | LCD display with LOI | ★ |
M5 | LCD display | ★ |
Transient protection(17)(20) | ||
T1 | Transient terminal block | ★ |
Manifold for remote mount option | ||
F2 | 3-valve manifold, SST | ★ |
F6 | 5-Valve Manifold, SST | ★ |
Plantweb™ control functionality(21) | ||
A01 | FOUNDATION Fieldbus Control Function Block Suite | ★ |
Plantweb diagnostic functionality | ||
DA0(13) | Loop Integrity HART Diagnostic | ★ |
D01(21) | FOUNDATION Fieldbus Diagnostic Suite | ★ |
Low power output | ||
C2 | 0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only) | |
Alarm levels(13) | ||
C4(22) | NAMUR alarm and saturation levels, high alarm | ★ |
CN(22) | NAMUR alarm and saturation levels, low alarm | ★ |
CR | Custom alarm and saturation signal levels, high alarm | ★ |
CS | Custom alarm and saturation signal levels, low alarm | ★ |
CT | Rosemount standard low alarm | ★ |
Ground screw(17)(23) | ||
V5 | External ground screw assembly | ★ |
Configuration buttons | ||
D4(13) | Analog zero and span | ★ |
DZ(24) | Digital zero trim | ★ |
HART Revision Configuration (requires HART Protocol output code A)(4) | ||
HR5 | Configured for HART Revision 5 | ★ |
HR7 | Configured for HART Revision 7 | ★ |
Typical model number: 3051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5 |
Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.
If needed, please contact us for specific prices.
OUR MAIN BRAND:
Company Details
Business Type:
Distributor/Wholesaler,Trading Company,Seller
Year Established:
2009
Total Annual:
100000-200000
Employee Number:
15~30
Ecer Certification:
Active Member
Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti... Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti...
Get in touch with us
Leave a Message, we will call you back quickly!