| Payment Terms | L/C, D/A, D/P, T/T |
| Supply Ability | 5000 KM per month |
| Delivery Time | 15 working days |
| Packaging Details | Wooden Iron Drum |
| Conductor | Copper |
| Insulation | XLPE |
| Wrapping Tape | LSOH BendingTape |
| Sheath | LSOH |
| Rated Voltage | 1KV 10KV 15KV 20KV 35KV |
| Cores No. | Single core |
| Corporation | shenghua group |
| Brand | Sh Cable |
| Brand Name | SHAN CABLE |
| Model Number | Single Core CU/XLPE/LSOH FR Cable |
| Certification | CE/KEMA |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Insulation Low Smoke Zero Halogen Power Cable With Multi Core CU Conductor
Customized Color Low Smoke Zero Halogen Cable 1.5mm2 - 800mm2 Environmental
LSZH Power Cable Low Smoke Zero Halogen Wire 1 Core 2 Core 3 Core WDZA-YJY
Colored Multicore Low Smoke Zero Halogen Cable For Hospital Buildings
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T | Supply Ability | 5000 KM per month |
| Delivery Time | 15 working days | Packaging Details | Wooden Iron Drum |
| Conductor | Copper | Insulation | XLPE |
| Wrapping Tape | LSOH BendingTape | Sheath | LSOH |
| Rated Voltage | 1KV 10KV 15KV 20KV 35KV | Cores No. | Single core |
| Corporation | shenghua group | Brand | Sh Cable |
| Brand Name | SHAN CABLE | Model Number | Single Core CU/XLPE/LSOH FR Cable |
| Certification | CE/KEMA | Place of Origin | CHINA |
| High Light | low smoke halogen free cable ,lszh power cable | ||
2 Core 0.6/1kV CU/MICA/XLPE/LSOH Fire Resistant Cable Environmental Cable
Construction
1 Conductor: Compactstranded copperconductor, Cl.2 as perlEC60228
(11 MicaTape
③lnsulation:XLPE(cross-linkedpolyethylene)ratedat90°C
(1111 Filler
(5: Wrapping Tape: LSOH BendingTape
⑥Sheath:LSOH,blackorothercolors,asperlEC60332,60502-1
CodeDesignation
YJ:XLPEinsulation Y: LSOH sheath
Applications
Forlaying indoors and outdoors.Able to bear certain traction during installation, but not extemal mechanical forces. Laying single core cable in magnetic ducts is not allowed.
Standards
lnternational: IEC60502. IEC60228, (lEC60332-3forFRcableonly) China: GB/T12706,(GB/T18380-3 for FR cable only)
Other standards such as BS, DIN and lCEAupon request
Technical data
Ratedvoltage: 0.6/ 1㎸
Maximum Conductor Temperature: under normal (90°C), emergency(130°C) or short circuit no more than5 s(250°C) conditions Min.AmbientTemp.-15°C,lnstallationTemp.0°C
![]()
Company Details
Business Type:
Manufacturer
Year Established:
1997
Total Annual:
150000000-200000000
Employee Number:
5000~6000
Ecer Certification:
Verified Supplier
.gtr-container-f7h2k9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 15px; line-height: 1.6; box-sizing: border-box; } .gtr-container-f7h2k9 .gtr-title-f7h2k9 { font-size: 18px; font-weight: bold... .gtr-container-f7h2k9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 15px; line-height: 1.6; box-sizing: border-box; } .gtr-container-f7h2k9 .gtr-title-f7h2k9 { font-size: 18px; font-weight: bold...
Get in touch with us
Leave a Message, we will call you back quickly!