China factories

China factory - Shanghai Shenghua Cable (Group) Co., Ltd.

Shanghai Shenghua Cable (Group) Co., Ltd.

  • China,Shanghai ,Hunan
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Shanghai Shenghua Power Cable Electrical FRC 4 Core Heat Resistant Cable 1.5mm -
China Shanghai Shenghua Power Cable Electrical FRC 4 Core Heat Resistant Cable 1.5mm -

  1. China Shanghai Shenghua Power Cable Electrical FRC 4 Core Heat Resistant Cable 1.5mm -
  2. China Shanghai Shenghua Power Cable Electrical FRC 4 Core Heat Resistant Cable 1.5mm -

Shanghai Shenghua Power Cable Electrical FRC 4 Core Heat Resistant Cable 1.5mm -

  1. MOQ: 1000m
  2. Price: USD0.03-5.0
  3. Get Latest Price
Supply Ability 10KM per Week
Delivery Time As per schedule
Packaging Details 100m/roll or customized
Color Customized
Size 1.5mm2 -800mm2
Rated Voltage 0.6/1kV
Insulation PVC
Sample Optional
Number of cores 1,2,3,4,5
Temperature 90℃
Corporation shenghua group
Brand Sh Cable
Brand Name SHANCABLE
Model Number NH-YJV
Certification CE/KEMA/ISO/PCCC
Place of Origin SHANGHAI,CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10KM per Week Delivery Time As per schedule
Packaging Details 100m/roll or customized Color Customized
Size 1.5mm2 -800mm2 Rated Voltage 0.6/1kV
Insulation PVC Sample Optional
Number of cores 1,2,3,4,5 Temperature 90℃
Corporation shenghua group Brand Sh Cable
Brand Name SHANCABLE Model Number NH-YJV
Certification CE/KEMA/ISO/PCCC Place of Origin SHANGHAI,CHINA
High Light 1.5mm Heat Resistant Cable800mm Heat Resistant Cable4 Core Heat Resistant Cable

Electrical FRC 4 Core Heat Resistant Cable 1.5mm - 800mm 90℃ Temperature
 

Engineered for Survival: Shanghai Shenghua’s Fire Resistant Cables for Critical Infrastructure​​

In high-risk environments like hospitals, metro tunnels, and petrochemical plants, ​​circuit integrity during fires is non-negotiable​​. Shanghai Shenghua Power Group Cable addresses this with its ​​FRC 4-Core LSOH Fire Resistant Cables​​—designed to maintain power transmission even at ​​1,000°C for 90+ minutes​​ while emitting zero toxic smoke 




​​Core Technology: Triple-Layer Fire Defense​​

  1. ​​Mica Tape Firewall​​: Wrapped around copper conductors, mica tape withstands ​​250°C during 5-second short circuits​​ and ​​750°C+ in prolonged fires​​, preventing conductor exposure and ensuring circuit integrity 

  2. ​​LSOH Insulation & Sheath​​: Halogen-free materials reduce toxic gas emissions (HCl <0.5%) and smoke density (>60% light transmittance), aligning with IEC 61034-2 and IEC 60754-1 

  3. ​​XLPE Thermal Stability​​: Cross-linked polyethylene insulation enables ​​long-term operation at 90°C​​, outperforming PVC’s 70°C limit while resisting electrical degradation 

​​Certified Performance for Global Compliance​​

Shenghua’s cables exceed international safety benchmarks:

  • ​​Standards​​: IEC 60502, 60331 (fire resistance), 61034 (smoke density), and GB/T 12706 (China) 

  • ​​Certifications​​: CE, RoHS, CCC, and KEMA-tested reliability 

  • ​​Fire Ratings​​: Class ZA/ZB/ZC/ZD flame retardancy and 950°C fire resistance for emergency systems 

​​Installation & Durability Optimized​​

  • ​​Bending Flexibility​​: Multi-core cables require only ​​15× outer diameter​​ bends, easing installation in tight spaces 

  • ​​Environmental Resilience​​: Operates at ​​-0°C to 90°C​​ (preheating below 0°C) and resists chemicals, oils, and mechanical stress 

  • ​​Water & Impact Resistance​​: Withstands sprinkler systems and falling debris during fires—critical for evacuation safety 

​​Applications Where Failure Is Not an Option​​

  • ​​High-Rise Buildings​​: Powers fire lifts, smoke control, and emergency lighting (e.g., NH-YJV32 variant) 

  • ​​Power Stations & Petrochemical Plants​​: Ensures uninterrupted operation of critical control systems 

  • ​​Metro Tunnels​​: LSOH properties aid visibility during evacuations 

​​Technical Specifications​​

Cross-Section (mm²) Outer Diameter (mm) Weight (kg/km) Max. DC Resistance (Ω/km) Current Rating (Air)
4×1.5 14.4 241 12.1 20A
4×120 52.5 5,374 0.153 285A
4×240 73.1 10,569 0.0754 440A
Full specs include 35+ configurations (1.5mm²–800mm²) with PVC/LSZH sheath options.




​​Why Shenghua Stands Apart​​

  • ​​30+ Years of Expertise​​: Custom solutions for complex projects (e.g., skyscrapers, offshore platforms) 
    2
    .
  • ​​Rigorous Testing​​: On-site fire labs validate circuit integrity under BS 7846 and BS 6387 standards 
    2
    4
    .
  • ​​Global Supply​​: CE/RoHS-compliant production with 15-day delivery from Shanghai hubs 
    3
    7


Cable Structure 
 
Conductor : Class 1,2,5 Flexible Copper Conductor
Screen:        Mica tape
Insulation:    PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V


Standard :


IEC 60502,60331 IEC 60227, IEC 60331, IEC 601034, IEC60754 GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

CE, CCC, KEMA

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: LSOH

Sheath: LSOH , black

Note: Insulation color as per standards or customer requirement


Applications

Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.


Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 601034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request


Technical data

Rated voltage: 0.6-KV

Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (the highest temperature of conductor shall no more than 250°C )

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%


Certificates

CE, RoHS, CCC, KEMA and more others at request


Nom. Cross-section of conductor Insulation Thickness Sheath Approx. Approx Max. D.C. Resistance of Conductor (20°C) Test Voltage Current Rating
mm2 mm Thickness O.D. Weight Ω/km A.C


mm mm kg/km
kV/5min In air(A) In soil(A)
1×1.5 0.7 1.8 7.7 81 12.1 3.5 22 33
4×1.5 0.7 1.8 14.4 241 12.1 3.5 20 27
4×2.5 0.7 1.8 15.4 295 7.41 3.5 26 35
4×4 0.7 1.8 16.5 369 4.61 3.5 34 45
4×6 0.7 1.8 17.8 463 3.08 3.5 43 57
4×10 0.7 1.8 20.9 667 1.83 3.5 60 77
4×16 0.7 1.8 23.4 930 1.15 3.5 83 105
4×25 0.9 1.8 27.1 1351 0.727 3.5 105 125
4×35 0.9 1.8 29.5 1772 0.524 3.5 125 155
4×50 1 1.9 38.4 2380 0.387 3.5 160 185
4×70 1.1 2 43.2 3302 0.268 3.5 200 225
4×95 1.1 2.2 47.3 4330 0.193 3.5 245 270
4×120 1.2 2.3 52.5 5374 0.153 3.5 285 310
4×150 1.4 2.5 58.3 6655 0.124 3.5 325 345
4×185 1.6 2.7 64.7 8246 0.0991 3.5 375 390
4×240 1.7 2.9 73.1 10569 0.0754 3.5 440 450
4×2.5+1×1.5 0.7 1.8 16.5 313 7.41
26 35
4×4+1×2.5 0.7 1.8 17.7 424 4.61
34 45
4×6+1×4 0.7 1.8 19.1 535 3.08
43 57
4×10+1×6 0.7 1.8 22.1 760 1.83
60 77
4×16+1×10 0.7 1.8 25.1 1071 1.15
83 105
4×25+1×16 0.7 1.8 29 1556 0.727
105 125
4×35+1×16 0.9 1.9 31.4 1976 0.524
125 155
4×50+1×25 1 2.1 36 2689 0.387
160 185
4×70+1×35 1.1 2.2 41.1 3719 0.268
200 225
4×95+1×50 1.1 2.4 46.3 4903 0.193
245 270
4×120+1×70 1.2 2.5 51 6165 0.153
285 310
4×150+1×70 1.4 2.7 55.8 7431 0.124
325 345
4×185+1×95 1.6 2.9 62.1 9192 0.0991
375 390
4×240+1×120 1.7 3.1 68.8 11860 0.0754
440 450

Operating characteristics
 
1, Long-term allowable operating temperature of cable conductor ≤70°C
2, Highest working temperature of cable in case of short circuit (the longest lasting time is not over 5s):≤300mm2 cable conductor ≤160°C, ≥300 mm2 cable conductor≤ 140°C.
3, The laying temperature should over 0℃,Permissible bending radius of cable:for single core unarmored cable, should be no less than 20 times of it’s outer diameter ; for multi-core unarmored cable, should be no less than 15 times of it’s outer diameter
4, With flame-retardant property,ZA,ZB,ZC,ZD are 4 types
5, The product is applicable for AC 50 Hz transmission and distribution lines with rated voltage of 0.6/1KV
 


Packing and shipping


We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1997

  • Total Annual:

    150000000-200000000

  • Employee Number:

    5000~6000

  • Ecer Certification:

    Verified Supplier

Company Profile   Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai.  As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji... Company Profile   Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai.  As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Shenghua Cable (Group) Co., Ltd.
  • No.7577 Hunan Road, Pudong New District. Shanghai China
  • https://www.shanpowercable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement