| Payment Terms | T/T |
| Supply Ability | 500 sets per year |
| Delivery Time | 60 days |
| Packaging Details | Cardboard boxes/Wooden crates |
| Ambient temperature | -50...+80 °C (-58...+176 °F) |
| Sensor length | Rod probe: 10 m /Rope probe: 45 m /Coaxial probe: 6 m |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Process pressure/max. overpressure limit | Vacuum...400 bar (Vacuum...5800 psi) |
| Measuring principle | Guided radar |
| material | Stainless steel |
| Brand Name | Endress+Huaser |
| Model Number | FMP54 |
View Detail Information
Explore similar products
Oil Storage Tank Liquid Level Measurement Instrument Equipped With FEEJOY RRF2
Oil Storage Tank Liquid Level Measurement Instrument Equipped With FEEJOY RRF5
Fuel Gas Skids With Highly And Accurate Proline Promass A 100 Coriolis Endress +
Fuel Gas Skids With Highly and Accurate Deltabar PMD75B Endress + Hauser
Product Specification
| Payment Terms | T/T | Supply Ability | 500 sets per year |
| Delivery Time | 60 days | Packaging Details | Cardboard boxes/Wooden crates |
| Ambient temperature | -50...+80 °C (-58...+176 °F) | Sensor length | Rod probe: 10 m /Rope probe: 45 m /Coaxial probe: 6 m |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus | Process pressure/max. overpressure limit | Vacuum...400 bar (Vacuum...5800 psi) |
| Measuring principle | Guided radar | material | Stainless steel |
| Brand Name | Endress+Huaser | Model Number | FMP54 |
| High Light | E+H Levelflex FMP54 radar level transmitter ,guided wave radar industrial tank sensor ,Endress Hauser level transmitter with warranty | ||
In steam boilers and high-pressure separators, most level devices can't handle the heat and pressure. The FMP54 can. It's the guided radar with a special ceramic-graphite seal and gas-tight feedthrough that works reliably up to 400 °C and 400 bar. Plants in power, oil & gas, and chemicals have been using it for years on feedwater drums, HP separators, and toxic media like ammonia.
| Measuring principle | Guided radar (TDR) |
| Process temperature | -196 °C to +450 °C (special versions) |
| Process pressure | Vacuum to 400 bar |
| Accuracy | ±2 mm |
| Measuring range | Rod: up to 10 m, Rope: up to 45 m, Coaxial: up to 6 m |
| Output | 4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Approvals | SIL 2/3, ATEX, IECEx, etc. |
Q: Does it work in saturated steam?
A: Yes – automatic compensation keeps readings accurate.
Q: How do I verify it's still good?
A: Heartbeat verification – quick test with report.
Q: Probe elongation in heat?
A: Special HT probes avoid drift.
Phone/WeChat/WhatsApp: +8615000725058
Email: edwardzhao@gbsxj.com
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2015
Total Annual:
30,000,000-50,000,000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; font-size: 14px; line-height: 1.6; color: #333; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 p { margin-bottom: 1em; text-align: left !important; } .gtr-container-x7y2z... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; font-size: 14px; line-height: 1.6; color: #333; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 p { margin-bottom: 1em; text-align: left !important; } .gtr-container-x7y2z...
Get in touch with us
Leave a Message, we will call you back quickly!