China factories

Chat Now Send Email
China factory - Xiangjing (Shanghai) M&E Technology Co., Ltd

Xiangjing (Shanghai) M&E Technology Co., Ltd

  • China,Shanghai ,Shanghai
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner
China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner

  1. China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner
  2. China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner
  3. China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner
  4. China ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner

ASCO Solenoid Valves and Samson 3730-3 Electropneumatic HART Valve Positioner

  1. MOQ: 1
  2. Price: 1900 dollars
  3. Get Latest Price
Payment Terms T/T
Supply Ability 600 units per year
Delivery Time 70 days
Packaging Details Carton + Wooden crate + Protective packaging
Load impedance ≤ 8.2 V
Hysteresis ≤ 0.3 %
Sensitivity ≤ 0.1 %
Permissible ambient temperature -20 to +80 °C, with metal cable gland -40 to +80 °C
Output signal 4 to 20 mA
Supply voltage 12 to 30 V DC
Brand Name Samson
Model Number 3730-3
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 600 units per year
Delivery Time 70 days Packaging Details Carton + Wooden crate + Protective packaging
Load impedance ≤ 8.2 V Hysteresis ≤ 0.3 %
Sensitivity ≤ 0.1 % Permissible ambient temperature -20 to +80 °C, with metal cable gland -40 to +80 °C
Output signal 4 to 20 mA Supply voltage 12 to 30 V DC
Brand Name Samson Model Number 3730-3
Place of Origin China
High Light ASCO solenoid control valvesSamson 3730-3 HART valve positionerelectropneumatic valve controller
Product Overview

Engineered by SAMSON, the Type 3730-3 electropneumatic positioner integrates a travel sensor, i/p converter, air booster, and microcontroller for high-precision valve control. It compares valve travel/angle to a 4-20 mA signal, outputting pneumatic pressure to actuators. Supports HART for communication and diagnostics, with firmware updates enhancing functionality like automatic option detection and extended configuration periods.

Key Features
  • Control Mechanism: PD controller with A/D conversion for real-time deviation correction.
  • Pneumatic Optimization: Volume restriction Q for actuator size adaptation; intermediate flow regulator for stable booster operation.
  • Diagnostics Integration: EXPERT+ for predictive maintenance via TROVIS-VIEW or DTM.
  • Safety Features: Fail-safe venting via optional solenoid; signal pressure limiting.
  • Communication: Serial SSP interface and HART (Rev 5/6) for parameter tuning.
  • Customizability: User-defined characteristics (e.g., butterfly/rotary plug valves).
  • Hazardous Area Ready: IP 65 rating, multiple explosion protections.
Technical Specifications
Parameter Details
Load Impedance ≤8.2 V (410 Ω at 20 mA)
Air Delivery (Pressurized/Vented) Δp=6 bar: 8.5/14.0 m³/h; Δp=1.4 bar: 3.0/4.5 m³/h
Influences Temperature: ≤0.15%/10K; Vibration: ≤0.25% up to 2000 Hz/4g
Explosion Protection EEx ia IIC T6, EEx nA II T6, IECEx, FM/CSA IS/NI
Communication HART impedance: Receive 350-450 Ω, Send ~155 Ω
Binary Contacts No Ex: R=348 Ω (conductive); Ex: ≥2.1 mA / ≤1.2 mA
Software Requirements TROVIS-VIEW module 3730-3; HART DTM for FDT frames
Applications

Optimized for industrial control in environments with variable transit times or harsh conditions, including throttling in pipelines and use with external sensors for remote setups. Applicable to IEC 60534-6 linear actuators or VDI/VDE 3845 rotary ones, often in petrochemical or power generation for flow regulation.

Frequently Asked Questions
  1. What causes 'No emergency mode' (Code 76)? Indicates lack of fallback during faults; check firmware and settings.
  2. How to perform zero calibration? Access via Code 6 after initialization; tracks calibrations since last init.
  3. Can transit times be limited? Yes, via Codes 21/22 up to 240 s to prevent rapid actuator engagement.
  4. What if initialization fails? Reset to defaults (Code 36) or check lever/pin position.
  5. How to integrate with PLC? Binary inputs per EN 61131-2, P_max=400 mW.
Contact Us

Phone/WeChat/WhatsApp: +8613916209596

Email: svetama@gbsxj.com

Related Products
  • Type 3730-31000000400000009.03: Specific variant with HART.
  • TROVIS 3730-3: Upgraded smart positioner.
  • Type 3730-4: With PROFIBUS-PA.
  • Type 3731-3: For explosive atmospheres.
  • Accessories: Type 3710 Reversing Amplifier.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other

  • Year Established:

    2015

  • Total Annual:

    30,000,000-50,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; font-size: 14px; line-height: 1.6; color: #333; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 p { margin-bottom: 1em; text-align: left !important; } .gtr-container-x7y2z... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; font-size: 14px; line-height: 1.6; color: #333; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 p { margin-bottom: 1em; text-align: left !important; } .gtr-container-x7y2z...

+ Read More

Get in touch with us

  • Reach Us
  • Xiangjing (Shanghai) M&E Technology Co., Ltd
  • No.6 Building,No.98 Lane, No.1 Fulian Road, Baoshan District, Shanghai, China
  • https://www.shgongboshi.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement