| Payment Terms | T/T |
| Material | Aluminum Alloy |
| Type | Control,pneumatic |
| Power | Pneumatic,electric |
| Delivery Time | 5~8 weeks |
| Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM |
| Supply Ability | 2,750 units per year |
| Standard or nonstandard | Standard |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Structure | Control,Angle stroke |
| Model Number | 520MD |
| Brand Name | Flowserve Logix |
View Detail Information
Explore similar products
Advanced Self-Diagnostics and IP66 Ingress Protection Control Valve Positioner
Original Masoneilan SVI2 Smart Valve Positioner China Pressure Balanced Single
Pressure Reducing Valve KOSO PRF300 PRF400 And EPA 801 Valve Positioner With
PN29 Butterfly Control Valve With 3400MD Digital Positioner High Performance
Product Specification
| Payment Terms | T/T | Material | Aluminum Alloy |
| Type | Control,pneumatic | Power | Pneumatic,electric |
| Delivery Time | 5~8 weeks | Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM | Supply Ability | 2,750 units per year |
| Standard or nonstandard | Standard | Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Structure | Control,Angle stroke | Model Number | 520MD |
| Brand Name | Flowserve Logix | ||
| High Light | Flowserve Logix 520MD valve positioner ,HART digital valve positioner ,precision control valve positioner | ||
Product Overview
The Flowserve Logix 520MD is a high-performance digital valve positioner engineered for accurate pneumatic actuator control. It accepts a two-wire 4-20mA input with HART 5, 6, and 7 communication and provides a pneumatic output for both rotary and linear actuators. The unit combines precise positioning and tuning capabilities with simple setup and powerful diagnostic functions.
A multi-variable gain tuning algorithm allows the 520MD to make large step changes with minimal overshoot while maintaining resolution for very small step changes. Auto-tune cycles the actuator to generate a measured response and selects gain values that deliver appropriate actuator performance. A gain modifier selector can increase or decrease the calculated gain for optimal results.
DIP switches handle tuning mode and other common settings. For custom requirements, tuning sets can be modified with a handheld or ValveSight software to accommodate a wide range of actuator sizes and types. A two-stage control design provides faster response times and tighter control with low air consumption.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Flowserve |
| Communication Protocol | HART 5, 6 and 7 |
| Input Signal | 4-20mA |
| Data Interface | Wired |
| Diagnostics | Standard Diagnostic functionality through ValveSight software |
| Supply Pressure | 1.4–10.3 bar (20–150 psig) |
| Output Signal | Pneumatic (3-15 psi) |
| Accuracy | ±0.25% of span |
| Repeatability | < 0.25% |
| Mounting Type | Rotary and Linear actuators |
| Operating Temperature | -40°C to 85°C (-40°F to 185°F) |
| Enclosure Rating | IP66/NEMA 4X |
| Housing Material | Aluminum |
| Weight | 3.5 kg |
| Minimum Operating Current | 3.6 mA |
| Voltage Supply (Maximum) | 30 VDC |
| Air Consumption | 0.28–0.38 Nm³/h (0.17–0.23 SCFM) |
| Certifications | ATEX, FM, CSA, SIL 2 |
| Intrinsically Safe | Class I Division 1 Groups A, B, C, D; Class 1, Zone 0, AEx ia IIC |
| Nonincendive | Class I Division 2 Groups A, B, C, D |
| Humidity | 0-100% Non-condensing |
Application Industry
The Flowserve Logix 520MD serves oil and gas, chemical processing, power generation, water treatment, and pharmaceutical industries. It is used for pipeline and actuator control, reactor valve positioning, turbine bypass automation, flow regulation, and hygienic valve operations. Certified hazardous area ratings make it suitable for demanding process environments.
Common Problems
No LED blinking: Current is below 3.6 mA or wiring polarity is incorrect. Verify supply current is at least 3.6 mA and check polarity.
Erratic communications: HART signal issues. Check current source bandwidth is limited to 25Hz. Verify cable length and impedance. Use a compatible intrinsic safety barrier.
Unit does not respond to analog commands: Unit is in digital command mode or a calibration error occurred. Change command mode to analog. Recalibrate the unit.
Valve position reading not as expected: Position sensor mounting not at 180 degrees, stroke not calibrated, MPC active, or user characterization active. Reposition sensor. Calibrate stroke.
Position driven fully open or closed, not responding to command: Stroke not calibrated, Hall sensor inner loop not connected, wrong air action set, tubing reversed, or I/P converter issue.
Friction Calibration Required: No friction calibration performed since factory reset. Perform Friction Calibration using the display menu, handheld, or DTM.
Replacement Models
The Flowserve Logix 520MD series is a mature digital positioner platform. For applications requiring additional safety integrity, the Logix 520MD+ variant offers enhanced features. For newer installations, the Logix 3200MD and Logix 3800MD are alternative models within the same product family. For cross-vendor alternatives, verify actuator mounting, travel range, and communication protocol before ordering.
Product Overview
The Flowserve Logix 520MD is a high-performance digital valve positioner engineered for accurate pneumatic actuator control. It accepts a two-wire 4-20mA input with HART 5, 6, and 7 communication and provides a pneumatic output for both rotary and linear actuators. The unit combines precise positioning and tuning capabilities with simple setup and powerful diagnostic functions.
A multi-variable gain tuning algorithm allows the 520MD to make large step changes with minimal overshoot while maintaining resolution for very small step changes. Auto-tune cycles the actuator to generate a measured response and selects gain values that deliver appropriate actuator performance. A gain modifier selector can increase or decrease the calculated gain for optimal results.
DIP switches handle tuning mode and other common settings. For custom requirements, tuning sets can be modified with a handheld or ValveSight software to accommodate a wide range of actuator sizes and types. A two-stage control design provides faster response times and tighter control with low air consumption.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Flowserve |
| Communication Protocol | HART 5, 6 and 7 |
| Input Signal | 4-20mA |
| Data Interface | Wired |
| Diagnostics | Standard Diagnostic functionality through ValveSight software |
| Supply Pressure | 1.4–10.3 bar (20–150 psig) |
| Output Signal | Pneumatic (3-15 psi) |
| Accuracy | ±0.25% of span |
| Repeatability | < 0.25% |
| Mounting Type | Rotary and Linear actuators |
| Operating Temperature | -40°C to 85°C (-40°F to 185°F) |
| Enclosure Rating | IP66/NEMA 4X |
| Housing Material | Aluminum |
| Weight | 3.5 kg |
| Minimum Operating Current | 3.6 mA |
| Voltage Supply (Maximum) | 30 VDC |
| Air Consumption | 0.28–0.38 Nm³/h (0.17–0.23 SCFM) |
| Certifications | ATEX, FM, CSA, SIL 2 |
| Intrinsically Safe | Class I Division 1 Groups A, B, C, D; Class 1, Zone 0, AEx ia IIC |
| Nonincendive | Class I Division 2 Groups A, B, C, D |
| Humidity | 0-100% Non-condensing |
Application Industry
The Flowserve Logix 520MD serves oil and gas, chemical processing, power generation, water treatment, and pharmaceutical industries. It is used for pipeline and actuator control, reactor valve positioning, turbine bypass automation, flow regulation, and hygienic valve operations. Certified hazardous area ratings make it suitable for demanding process environments.
Common Problems
No LED blinking: Current is below 3.6 mA or wiring polarity is incorrect. Verify supply current is at least 3.6 mA and check polarity.
Erratic communications: HART signal issues. Check current source bandwidth is limited to 25Hz. Verify cable length and impedance. Use a compatible intrinsic safety barrier.
Unit does not respond to analog commands: Unit is in digital command mode or a calibration error occurred. Change command mode to analog. Recalibrate the unit.
Valve position reading not as expected: Position sensor mounting not at 180 degrees, stroke not calibrated, MPC active, or user characterization active. Reposition sensor. Calibrate stroke.
Position driven fully open or closed, not responding to command: Stroke not calibrated, Hall sensor inner loop not connected, wrong air action set, tubing reversed, or I/P converter issue.
Friction Calibration Required: No friction calibration performed since factory reset. Perform Friction Calibration using the display menu, handheld, or DTM.
Replacement Models
The Flowserve Logix 520MD series is a mature digital positioner platform. For applications requiring additional safety integrity, the Logix 520MD+ variant offers enhanced features. For newer installations, the Logix 3200MD and Logix 3800MD are alternative models within the same product family. For cross-vendor alternatives, verify actuator mounting, travel range, and communication protocol before ordering.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2015
Total Annual:
30,000,000-50,000,000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr... Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr...
Get in touch with us
Leave a Message, we will call you back quickly!