| Media | Water,Gas,steam,oil,Liquid |
| Payment Terms | T/T |
| Structure | Diaphragm,Control,Ball,Angle stroke,Other |
| Delivery Time | 5-8 weeks |
| Supply Ability | 2,900 units per year |
| Temperature of media | Medium Temperature,High Temperature,Normal Temperature,-60~550°C,-35℃~+45℃ |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Power | Pneumatic,Manual,Solenoid,electric,2x6W(24VDC) |
| Material | Stainless Steel,Casting,WCB,Aluminum Alloy,SS316L |
| Pressure | Medium Pressure,Low Pressure,High Pressure,1.6/4.0/6.4Mpa,200psi/PN16 |
| Model Number | DVC2000 |
| Brand Name | Fisher |
View Detail Information
Explore similar products
Foxboro SRD991 Series Smart Digital Valve Positioner HART 4-20mA for Control
Advanced Self-Diagnostics and IP66 Ingress Protection Control Valve Positioner
Original Masoneilan SVI2 Smart Valve Positioner China Pressure Balanced Single
Pressure Reducing Valve KOSO PRF300 PRF400 And EPA 801 Valve Positioner With
Product Specification
| Media | Water,Gas,steam,oil,Liquid | Payment Terms | T/T |
| Structure | Diaphragm,Control,Ball,Angle stroke,Other | Delivery Time | 5-8 weeks |
| Supply Ability | 2,900 units per year | Temperature of media | Medium Temperature,High Temperature,Normal Temperature,-60~550°C,-35℃~+45℃ |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm | Power | Pneumatic,Manual,Solenoid,electric,2x6W(24VDC) |
| Material | Stainless Steel,Casting,WCB,Aluminum Alloy,SS316L | Pressure | Medium Pressure,Low Pressure,High Pressure,1.6/4.0/6.4Mpa,200psi/PN16 |
| Model Number | DVC2000 | Brand Name | Fisher |
| High Light | Industrial digital valve controller 4-20mA HART ,DVC2000 series control valve controller ,Pneumatic control valve digital controller | ||
Product Overview
The DVC2000 digital valve controller is a communicating, microprocessor-based current-to-pneumatic valve positioner. It converts a 4-20 mA control signal into a pneumatic output to drive a single-acting pneumatic actuator. The unit retrofits easily in place of existing analog positioners.
The linkage-less feedback system uses magnetic sensing technology — no mechanical contact between the valve stem and the controller, so there are no wearing parts. The instrument has a local user interface with a multilingual LCD that allows configuration, calibration, and tuning directly at the valve. The two-stage positioner design provides a mechanical platform for responsiveness to small input changes and tighter process control.
For advanced diagnostics, ValveLink software can test the entire control valve assembly without disrupting the process, helping pinpoint problems before equipment fails. An optional I/O package includes two integral limit switches and a stem position transmitter.
Technical Specifications
| Parameter | Specification |
|---|---|
| Communication Protocol | HART, 4-20mA Analog |
| Input Signal | Electric |
| Data Interface | Wired |
| Diagnostics | Yes |
| Max Outlet Pressure | 101 psig |
| Mounting Type | Integral Mounted |
| Operating Temperature | Standard Temperature, High Temperature |
| Position Control | Throttling Control, On/Off |
| Power Source | Local |
| Process Control | Flow, Pressure, Temperature, Level |
| Supply Media | Air, Non Corrosive Gas |
| Area Classification | Intrinsically Safe, Non-incendive for CSA and FM |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, PED, UL, Peso, KGS, INMETRO, NEPSI, ANZEx |
| Weight | 1.5 kg / 3.3 lbs |
| Housing Material | Aluminum construction |
| Maximum Travel | 606 mm / 23-7/8 inches (single-acting pneumatic actuators) |
| Temperature Range | -40 to +80°C / -40 to +176°F |
| Maximum Inlet Pressure | 7 barg / 100 psig |
| Integral Mounting | Available on GX, 657, and 667 size i actuators |
Application Industry
The DVC2000 is used across chemical, oil and gas, refining, pulp and paper, power, food and beverage, pharmaceutical, and other process industries. It handles flow, pressure, temperature, and level control applications. The compact size and simple setup make it well-suited for standard control valves with short strokes and routine procedures.
Common Problems
Instrument will not communicate: Check available voltage. Confirm terminal voltage is within the 9–32 VDC range and inspect wiring connectors on the printed wiring board.
Flash ROM Fail: Restart the instrument. If the failure does not clear, replace the printed wiring board assembly.
Valve does not respond to control signals: Check pneumatic connections and supply pressure. Verify that the function block is in the correct mode.
Display shows alert symbol ⚠️: The DVC2000 self-diagnoses continuously. Check the alert record, which stores up to 20 alerts from Valve Alerts or Failure Alerts groups.
Replacement Models
The DVC2000 is a standard control valve positioner. The DVC6200 can directly replace the DVC2000 in many applications — they belong to the same product line and share compatible mounting. The DVC6200 offers advanced diagnostics and linkless feedback for critical control valves, while the DVC2000 remains a practical choice for routine applications. For cross-vendor alternatives, verify mounting, travel range, and communication protocol before ordering.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2015
Total Annual:
30,000,000-50,000,000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr... Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr...
Get in touch with us
Leave a Message, we will call you back quickly!