| Type | Control,pneumatic |
| Power | Pneumatic,electric |
| Payment Terms | T/T |
| Material | Aluminum Alloy |
| Supply Ability | 2,750 units per year |
| Standard or nonstandard | Standard |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Structure | Diaphragm,Angle stroke |
| Delivery Time | 5~8 weeks |
| Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM |
| Model Number | DVC6200 |
| Brand Name | Fisher |
View Detail Information
Explore similar products
Foxboro SRD991 Series Smart Digital Valve Positioner HART 4-20mA for Control
Advanced Self-Diagnostics and IP66 Ingress Protection Control Valve Positioner
Original Masoneilan SVI2 Smart Valve Positioner China Pressure Balanced Single
Pressure Reducing Valve KOSO PRF300 PRF400 And EPA 801 Valve Positioner With
Product Specification
| Type | Control,pneumatic | Power | Pneumatic,electric |
| Payment Terms | T/T | Material | Aluminum Alloy |
| Supply Ability | 2,750 units per year | Standard or nonstandard | Standard |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm | Structure | Diaphragm,Angle stroke |
| Delivery Time | 5~8 weeks | Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM | Model Number | DVC6200 |
| Brand Name | Fisher | ||
| High Light | HART Communication Digital Valve Positioner ,Linkage-Less Design Valve Controller ,4-20mA Signal Pneumatic Control Valve Positioner | ||
Product Overview
The Fisher DVC6200 is a FIELDVUE digital valve controller that communicates over HART. It takes a two-wire 4-20 mA signal and converts it into a pneumatic output to operate a valve actuator. The unit is built to replace analog positioners on most pneumatic actuators without adapter parts. A magnetic position sensor works without contact, so there is no linkage to wear out. The sealed electronics module tolerates high vibration, temperature changes, and dirty plant air.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Fisher |
| Communication Protocol | 4-20 mA HART |
| Input Signal | Electric |
| Data Interface | Wired |
| Diagnostics | Yes |
| Max Outlet Pressure | 145 psig |
| Mounting Type | Integral Mounted |
| Operating Temperature | Standard Temperature, High Temperature |
| Position Control | Throttling Control, On/Off |
| Power Source | Local |
| Process Control | Flow, Pressure, Temperature, Level |
| Supply Media | Air, Natural Gas, Nitrogen |
| Area Classification | Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive for FM |
| Certifications | CSA, FM, ATEX, IECEx, CUTR, Peso, KGS, INMETRO, NEPSI, TIIS, Natural Gas Certified, Single Seal Device; Marine Approvals: Lloyd‘s Register, Bureau Veritas, DNV, ABS |
| Actuator Compatibility (Linear) | Sliding-stem linear actuators with rated travel between 6.35 mm / 0.25 in. and 606 mm / 23.375 in. |
| Actuator Compatibility (Rotary) | Quarter-turn rotary actuators with rated travel between 45° and 180° |
| Housing Material | A03600 low copper aluminum alloy (standard); stainless steel (optional) |
| Elastomers | Nitrile (standard); Fluorosilicone (extreme temperature) |
| Weight (DVC6200 Aluminum) | 3.5 kg / 7.7 lbs |
| Weight (DVC6200 Stainless Steel) | 8.6 kg / 19 lbs |
| Weight (DVC6205) | 4.1 kg / 9 lbs |
| Weight (DVC6215) | 1.4 kg / 3.1 lbs |
| Minimum Terminal Voltage | 9.5 VDC for analog control; 10 VDC for HART communication |
Application Industry
The DVC6200 is used in refining, chemical, nuclear, oil and gas, power, pulp and paper, food and beverage, water and wastewater, pharmaceutical, and metals and mining. It controls flow, pressure, temperature, and level loops.
Common Problems
Instrument will not communicate: Check power supply, terminal voltage (should be 9–32 VDC), and wiring connectors on the printed wiring board.
Valve does not stroke from 0 to 100%: Verify pneumatic connections and supply pressure; check that function block is in the correct mode.
I/P converter output out of spec: May indicate a defective module base seal, defective relay, or a faulty 67CFR regulator.
Replacement Models
The DVC6200 retrofits existing analog positioner installations. It is a common upgrade from older DVC2000 units. For other brands, verify mounting, travel range, and communication protocol before ordering.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2015
Total Annual:
30,000,000-50,000,000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr... Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr...
Get in touch with us
Leave a Message, we will call you back quickly!