| Payment Terms | T/T |
| Material | Aluminum Alloy |
| Type | Control,pneumatic |
| Power | Pneumatic,electric |
| Delivery Time | 5~8 weeks |
| Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM |
| Supply Ability | 2,750 units per year |
| Standard or nonstandard | Standard |
| Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Structure | Control,Angle stroke |
| Model Number | 3200MD |
| Brand Name | Flowserve Logix |
View Detail Information
Explore similar products
Foxboro SRD991 Series Smart Digital Valve Positioner HART 4-20mA for Control
Advanced Self-Diagnostics and IP66 Ingress Protection Control Valve Positioner
Original Masoneilan SVI2 Smart Valve Positioner China Pressure Balanced Single
Pressure Reducing Valve KOSO PRF300 PRF400 And EPA 801 Valve Positioner With
Product Specification
| Payment Terms | T/T | Material | Aluminum Alloy |
| Type | Control,pneumatic | Power | Pneumatic,electric |
| Delivery Time | 5~8 weeks | Application | General,industrial |
| Standard | DIN,ANSI,BS,ASTM | Supply Ability | 2,750 units per year |
| Standard or nonstandard | Standard | Packaging Details | carton or wooden crate, 30 × 30 × 30 cm |
| Structure | Control,Angle stroke | Model Number | 3200MD |
| Brand Name | Flowserve Logix | ||
| High Light | Flowserve Logix 3200MD valve positioner ,HART 5 smart positioner ,pneumatic valve positioner with warranty | ||
Product Overview
The Flowserve Logix 3200MD is a digital valve positioner built with piezo technology for dependable control of pneumatic actuators. It receives a two-wire 4-20mA signal and adjusts the valve actuator according to that analog command. Local pushbuttons, a HART handheld, or SoftTools software can handle configuration. On-board status LEDs, DIP switches, and calibration buttons simplify setup. Auto tuning with dynamic gain selection maintains stable and responsive control.
The unit supports double-acting and single-acting actuators in both linear and rotary mountings. It is not sensitive to supply pressure changes and accepts supply pressures from 30 to 150 psig. The explosion-proof enclosure carries Class I Division 1 Groups B-D, Ex d IIB+H2, and AEx d IIB+H2 ratings, and the positioner is SIL 2 capable.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Flowserve |
| Communication Protocol | HART 5 |
| Input Signal | 4-20mA |
| Data Interface | Wired |
| Diagnostics | 24/7 Local Fault Monitoring; Local Valve Signature Storage |
| Supply Pressure | 30 to 150 psig |
| Mounting Type | Rotary and Linear actuators |
| Operating Temperature | -52°C to +85°C (-62°F to +185°F) |
| Housing Material | Cast, Powder-painted Aluminum; Stainless Steel |
| Weight (Aluminum) | 3.9 kg (8.3 lbs) |
| Weight (Stainless Steel) | 9.3 kg (20.5 lbs) |
| Minimum Operating Current | 3.6 mA |
| Voltage Supply (Maximum) | 30.0 VDC |
| Compliance Voltage | 10.0 VDC @ 20 mA |
| Area Classification | Explosion Proof: Class I Div 1 Groups B-D; Intrinsically Safe: Class I Div 1 Groups A-G; Non-Incendive: Class I Div 2 A-D |
| Certifications | SIL 2 |
| Additional Features | RFI/EMI Immunity; FISCO Compliant; Auto Tune; High Friction Stability; Flash Ram Upgrade; Local Adjustable Gain |
Application Industry
The Flowserve Logix 3200MD is used in oil and gas, chemical processing, power generation, water treatment, and pharmaceutical industries. It handles pipeline and actuator control, reactor valve positioning, turbine bypass automation, and flow regulation in plants.
Common Problems
No LED blinking: Current is below 3.6 mA or wiring polarity is incorrect. Verify supply current is at least 3.6 mA and check polarity.
Erratic communications: HART signal issues. Check current source bandwidth is limited to 25Hz. Verify cable length and impedance. Use a compatible intrinsic safety barrier.
Unit does not respond to analog commands: Unit is in digital command mode or a calibration error occurred. Change command mode to analog. Recalibrate the unit.
Valve position reading not as expected: Position sensor mounting not at 180 degrees, stroke not calibrated, or MPC active. Reposition sensor. Calibrate stroke.
Position driven fully open or closed: Stroke not calibrated, Hall sensor inner loop not connected, wrong air action set, or tubing reversed. Calibrate stroke. Check hardware connections.
Friction Calibration Required: No friction calibration performed since factory reset. Perform Friction Calibration using the display menu, handheld, or DTM.
Replacement Models
The Flowserve Logix 3200MD is a mature digital positioner platform. For additional safety integrity, the Logix 3200MD+ variant offers enhanced features. For newer installations, the Logix 3800 is an alternative model within the same product family. For cross-vendor alternatives, verify actuator mounting, travel range, and communication protocol before ordering.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2015
Total Annual:
30,000,000-50,000,000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr... Xiangjing (Shanghai) - Leading Distributor of Pneumatic and Electric Control Valves Established in Shanghai, China, Xiangjing(Shanghai) Mechanical and Electrical Tech Co.,Ltd has been a trusted distributor of high-quality pneumatic and electric control valves for many years. With extensive industr...
Get in touch with us
Leave a Message, we will call you back quickly!