China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane
China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane

  1. China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane
  2. China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane
  3. China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane
  4. China Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane

Polyethersulfone PES Ultrafiltration Membrane 80lmh Water Flux UF Membrane

  1. MOQ: 5
  2. Price:
  3. Get Latest Price
Packaging Details Standard export packaging
Core Components uf membrane
Product name hollow fiber ultrafiltration membrane, ultrafiltration system, PVC Hollow fiber UF membrane module
Pore size customized., from 1μm to 0.05μm, 0.01micron, 1.0μm, 0.2μm
Module Inside-out
Nominal Pore Size 0.1 μm
Membrane Structure Hollow Fiber
Membrane Material Polyethersulfone (PES)
Water Flux 50-80lmh
Product Housing U-PVC material
Color White
Brand Name SINOMEMB
Model Number SNU-HI-1-660
Certification NSF
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Standard export packaging Core Components uf membrane
Product name hollow fiber ultrafiltration membrane, ultrafiltration system, PVC Hollow fiber UF membrane module Pore size customized., from 1μm to 0.05μm, 0.01micron, 1.0μm, 0.2μm
Module Inside-out Nominal Pore Size 0.1 μm
Membrane Structure Hollow Fiber Membrane Material Polyethersulfone (PES)
Water Flux 50-80lmh Product Housing U-PVC material
Color White Brand Name SINOMEMB
Model Number SNU-HI-1-660 Certification NSF
Place of Origin China
High Light Polyethersulfone PES Ultrafiltration Membrane80lmh PES Ultrafiltration MembranePolyethersulfone UF Membrane Module

SINOMEMB ® UF membrane module SNU-HI-1-660 type

The core SINOMEMB ® series SN U-HI-1-660 hollow fiber UF membrane element membrane module is ideal for systems with a capacity of 50 m 3 /hr (220 gpm) and below. The 60-inch length of this module is more effective at treating a variety of feedwaters than longer modules. In addition, the diameter of the membrane module is 6 inches , and the size is small, which can realize a relatively compact design , which is very suitable for occasions with limited space , and helps customers to achieve a more economical membrane system design , and can be widely used in surface water and well water , seawater , industrial wastewater, secondary and tertiary treatment of sewage and other water treatment applications.

Ø Membrane element specifications

Membrane element model

Effective membrane area

ft 2 (m 2 )

Effective volume

G( L )

weight empty /full of water

( kg )

SN U-HI-1-660 355(33) 4.2(16) 25/41
Inlet size Water outlet size Concentrated water outlet size Membrane Polymer
DN50 DN50 DN32 PES
Membrane inner diameter/outer diameter (mm) Filtration precision (μ m ) shell material Sealant material
1.0/1.6 0.01 U-PVC epoxy resin

Ø Membrane element operating parameters

Filtration flux ( 25℃ ) L/㎡·hr 50-80
Flow range m³/hr 1.65-2.64
Maximum influent turbidity (NTU) ≤50
Maximum resistance to residual chlorine (NaCLO) (ppm) Continuous: 50; Momentary: 500
Maximum anti-suspended solid capacity (ppm) ≤50
Maximum influent particle size ( μm ) 100
Working temperature (℃) 1-40
pH range 1-13
Maximum water production (L/m³·h) 120
Maximum inlet pressure (Mpa) 0.625
Maximum transmembrane pressure difference (Mpa) 0.21
Maximum backwash pressure (Mpa) 0.25
Maximum air flushing flow rate (Nm³/hr) /
General backwash cycle (min) 15-60
General backwash time (sec) 30-60
General backwash flow rate (L/m³·h) 100-360
General chemical enhanced backwash cycle (day) 1-15
General chemical backwashing time (min) 1-15
General chemical cleaning cycle (day) 30-180
General chemical cleaning time (min) 90-480
General chemical cleaning chemicals NaClO or H2O2 500ppm , NaOH (PH≤13), HCl (PH≥1 )
How to run /operate inside-out / full flow or cross flow filtration
Expected water production SDI ≤2.5
Expected product water turbidity NTU ≤0.1
Bacteria removal rate (log) >6
E. coli removal rate (log) >6
service life ≥3 years under standard conditions

Ø UF membrane element size

L L1 L2 L3 L4 Diameter Φ
1860mm 1500mm 1610mm 1710mm 125mm 165mm
(73.2)in (59.1)in (63.4)in (67.3)in (4.9)in (6.5)in

Ø Operation Guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum withstand pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Ø Product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Ø Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.
for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2016

  • Total Annual:

    10000000-15000000

  • Employee Number:

    101~200

  • Ecer Certification:

    Verified Supplier

SINOMEMB Environmental Industry Group founded in 2012, it's a high-tech enterprise group with membrane separation technology as its core. From the original water treatment membrane product development, manufacturers, gradual development to build a high-end separation membrane materials, environmenta... SINOMEMB Environmental Industry Group founded in 2012, it's a high-tech enterprise group with membrane separation technology as its core. From the original water treatment membrane product development, manufacturers, gradual development to build a high-end separation membrane materials, environmenta...

+ Read More

Get in touch with us

  • Reach Us
  • Sinomemb Environment Technology (beijing) Co.,
  • 1305, Block B, Zhongtiejian Plaza, Beijing, China
  • https://www.sinomembtech.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement