Payment Terms | L/C, , T/T, Western Union, MoneyGram |
Supply Ability | 1 set per month |
Delivery Time | 30 Days |
Packaging Details | Plywood |
Applied Standard | IEC60898-1:2015 |
Applied Clause | Clause 9.7 |
AC Output Voltage Range | 100 ~ 5000V |
IR Output Voltage Range | 200~2500V |
DC Output Voltage Range | 200~6000V |
GR Output Voltage Range | 1.00~32.00A |
Brand Name | Sinuo |
Model Number | SN6872F |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
IEC 60898-1 Clause 9.10 Circuit Breaker Tripping Test Equipment 2500A
IEC 61009-1 Residual Current Tester for Circuit Breaker 500A
IEC 61009-1 Residual Current Protector Device Action Characteristic Tester
IEC60898-1 Clause 9.10 Circuit Breaker Tripping Comprehensive Tester 10000A
Product Specification
Payment Terms | L/C, , T/T, Western Union, MoneyGram | Supply Ability | 1 set per month |
Delivery Time | 30 Days | Packaging Details | Plywood |
Applied Standard | IEC60898-1:2015 | Applied Clause | Clause 9.7 |
AC Output Voltage Range | 100 ~ 5000V | IR Output Voltage Range | 200~2500V |
DC Output Voltage Range | 200~6000V | GR Output Voltage Range | 1.00~32.00A |
Brand Name | Sinuo | Model Number | SN6872F |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | emc test systems ,electromagnetic testing services |
IEC60898-1 MCCB dielectric properties Modular Intelligent Safety Tester
Standards & Clauses:
This tester conforms to the requirements of numerous standards, including but not limited to IEC 61009-1:2012 and IEC 60898-1:2015 Clause 9.7.
Featuring seven comprehensive functions—AC withstand voltage, DC withstand voltage, insulation resistance, grounding, leakage current, power, and low-voltage start testing—this advanced platform provides all-in-one safety testing capabilities.
With its globally advanced modular architecture, the system integrates safety compliance testing with intelligent information management. Supporting data collection, storage, analysis, and transmission, it offers a cutting-edge solution for smart, connected manufacturing environments and is the optimal choice for intelligent factory testing.
Technical Parameters:
Model | Test Project | Function | Accuracy | ||||||||
ACW | DCW | IR | GB | LC | PWR | STR | O/S | Variable frequency power supply | transformer | 1% | |
SN6872F | √ | √ | √ | √ | √ | √ | √ | √ | √ |
Rated output | 5KV/100mA, short-circuit current>200mA |
The output voltage range | 100 ~ 5000V |
Output voltage accuracy | ±(1%× set value +2 words) |
Voltage resolution | 1V |
Output frequency | 50/60Hz |
Frequency accuracy | ±0.1Hz |
Output adjustment | ±(1%× set value +2 words) |
Current upper limit | 0.00 to 100.00mA |
The current lower limit | 0.000 to 9.999mA |
Current measurement range | 0.00 ~ 100.0mA |
The current measurement resolution | 0.001/0.01mA |
Current measurement accuracy | ±(1%× reading value +5 words) |
Slow rise time | 0-999.9s |
Slow down time | 0.1-999.9s |
Test time | 0,0.3-999.9s |
Time resolution | 0.1s |
Time accuracy | ±(0.2% x set value +1 word) |
Arc detection | 0-9 |
Current compensation range | 0.000-20.00mA |
Rated output | 6KV/10mA |
The output voltage range | 200~6000V |
Output voltage accuracy | ±(1%× set value +2 words) |
The output ripple | <2% |
Current upper limit | 0.00 to 10.00mA |
The current lower limit | 0.000 to 9.999mA |
Current measurement range | 0.00 ~ 10.0mA |
The current measurement resolution | 0.001/0.01mA |
Current measurement accuracy | ±(1%× reading value +5 words) |
Slow rise time | 0-999.9s |
Slow down time | 0.1-999.9s |
Test time | 0,0.3-999.9s |
Time resolution | 0.1s |
Time accuracy | ±(0.2% x set value +1 word) |
Arc detection | 0-9 |
Current compensation range | 0.000-5.000mA |
Discharge time | 100ms |
Rated output | 2500V/50GΩ | |
The output voltage range | 200~2500V | |
Voltage resolution | 1V | |
Output voltage accuracy | ±(1%× set value +2 words) | |
Ripple coefficient | ≤2% | |
Resistance measuring range | 0.00 to 10.00mA | |
Resolution of resistance measurement | 0.000 to 9.999mA | |
Accuracy of measurement | 1.000MΩ~999.9MΩ Output 200-500V | ±(7%× reading value +3 words) |
1.000MΩ~999.9MΩ Output 501-2500V | ±(5%× reading value +3 words) | |
1.00GΩ~10.00GΩ Output 501-2500V | ±(7%× reading value +3 words) | |
10.00GΩ~50.00GΩ Output 1000-2500V | ±(15%× reading value +3 words) | |
Slow rise time | 0-999.9s | |
Slow down time | 0.1-999.9s | |
Test time | 0,0.3-999.9s | |
Time resolution | 0.1s | |
Time accuracy | ±(0.2% x set value +1 word) | |
Discharge time | <100ms |
Rated output | 32A/600mΩ | |
The output voltage range | 1.00~32.00A | |
Voltage resolution | 0.01A | |
Output voltage accuracy | ±(1%× set value +3words) | |
Current fluctuations | ≤0.4% x Set value/min | |
The output voltage | 3.00-8.00V AC | |
The resolution of the | 0.1V | |
The output frequency | 50Hz/60Hz | |
Frequency accuracy | ±0.1Hz | |
Upper/lower resistance setting | 0.1-600mΩ | |
Resistance range | 0.1-600mΩ | 1.00~10.00A |
0.1 the Rm Ω R=(6400/ set current value)m ω | 10.10~64.00A | |
Resolution of resistance measurement | 0.1/1mΩ | |
Accuracy of resistance measurement | ±(1%× reading value +3 words) | |
Voltage measuring range | 0.00-6.40V AC | |
Voltage measurement resolution | 0.01V | |
Accuracy of voltage measurement | ±(1%× reading value +3 words) | |
Resistance compensation | 0-100mΩ | |
The test of time | 0,0.3-999.9s | |
Temporal resolution | 0.1s | |
Time accuracy | ±(0.2%× reading value +3 words) |
Test Probe Setup | Ground contact current: G-L, G-N, AUTO (G-L, G-N) | |
Contact current to surface: PH-L, PH-PL | ||
7 kinds of human body simulation circuits (MD) are standard (optional customized human body network) | MD A. | GB12113/IEC60990,GB4706.1/IEC60335-1 GB7000.1/IEC60598-1,GB4943.1/IEC60950-1 GB8898.1/IEC60065 |
MD B. | UL1563 | |
MD C. | GB4943.1/IEC60950-1 | |
MD D. | UL544P
| |
MD E. | UL544NP/UL484/UL923/ UL1029/UL471/UL867/UL697 | |
MD F. | GB12113/IEC60990 GB7000.1/IEC60598-1 | |
MD G. | GB4943.1/IEC60950-1 | |
Test power supply
| Polarity Switching: On, Off, Auto | |
Grounded and Un-grounded Conversion: On, Off | ||
The transition between the normal connection state and the non-connection state of the neutral line of the test power supply: ON, OFF | ||
Test voltage output | Single-phase, requires an external isolation transformer or variable frequency power supply; provides the voltage and frequency required for the test. | |
Test voltage upper limit setting | 0.0V~300.0V AC | |
Test voltage lower limit setting | 0.0V~300.0V AC
| |
Test voltage resolution | 0.1V ; 45Hz~65Hz | |
Test voltage measurement range | 0.0V~300.0V,45Hz~65Hz | |
Test voltage resolution | 0.1V,45Hz~65Hz | |
Test voltage measurement accuracy | 20.0V~300.0V: ±(2%×reading value+3 digits) | |
load current | 20A | |
Overcurrent Protection | RMS current and response time: 25A<3s | |
Peak current and response time: 70A<10ms | ||
Touch current measurement upper limit (effective value) | 0.0mA~20.000mA | |
Touch current measurement lower limit (RMS) | 0.0mA~20.000mA | |
Touch current measurement resolution (RMS) | 0.001mA | |
Touch current measurement judgment error (RMS) | AC | ±(1%×reading value+3 digits) |
15Hz≤f≤ 100kHz | ±(1%×reading value+3 digits) | |
100kHz<f≤ 1000kHz
| ±(2%×reading value+3 digits) | |
Touch current compensation range | 0.000~1.000mA; automatic measurement; can be turned on or off | |
testing time | 0; (1 ~999.9); 0 is infinite | |
Test time resolution | 0.1s | |
test accuracy | ±( 1% × set value + 1 word) | |
test method | AUTO (G-L, G-N); time for 1 and a half times each |
Power upper/lower limit settings | 0.0~6000W | |
Power measurement range | 0.0-999.9W,1000-6000W | |
Power measurement resolution | 0.1W,1W | |
Power Measurement Accuracy | PF>0.9 | ±(0.1%×reading value+0.1%×range) |
PF≤0.9 | ±(0.4%×reading value+0.1%×range) | |
Voltage measurement range | 0.0-300.0V | |
Voltage measurement resolution | 0.1V | |
Voltage measurement accuracy | ±(0.1%×reading value+0.1%×range) | |
testing time | 0,0.3~999.9s | |
Time resolution | 0.1s | |
time accuracy | ±(0.2%×setting value+1 word) |
Current upper/lower limit setting | 0.00-20.00A |
Current measurement range | 0.000-9.999A ,10.00-20.00A |
Current measurement resolution | 0.001A/0.01A |
Current measurement accuracy | ±(0.1%×reading value+0.1%×range) |
Voltage measurement range | 0.0-300.0V |
Voltage measurement resolution | 0.1V |
Voltage measurement accuracy | ±(0.1%×reading value+0.1%×range) |
Testing time | 0,0.3~999.9s |
Time resolution | 0.1s |
time accuracy | ±(0.2%×setting value+1 word) |
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...
Get in touch with us
Leave a Message, we will call you back quickly!