Payment Terms | L/C, , T/T, Western Union, MoneyGram |
Supply Ability | 1 set per month |
Delivery Time | 60 Days |
Packaging Details | Plywood |
Frequency Range | 150kHz~230MHz |
Highest Test Level | 10V |
Linear Power | 75W |
Amplifier Gain | 50dB |
Brand Name | Sinuo |
Model Number | SN6611 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
IEC 61000-4-12 EMC Test Equipment Ringing Wave Generator Oscillatory Waves
IEC 61000-4-11 EMC Test Equipment Single Phase Voltage Dips and Interruptions
IEC 61000-4-4 6kV Intelligent Electrical Fast Transient Immunity Test EFT
IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator
Product Specification
Payment Terms | L/C, , T/T, Western Union, MoneyGram | Supply Ability | 1 set per month |
Delivery Time | 60 Days | Packaging Details | Plywood |
Frequency Range | 150kHz~230MHz | Highest Test Level | 10V |
Linear Power | 75W | Amplifier Gain | 50dB |
Brand Name | Sinuo | Model Number | SN6611 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | emc test systems ,electromagnetic testing services |
IEC 61000-4-6 Conducted Susceptiblility (CS) Conducted Immunity Test System
Standards & Clauses:
IEC 61000-4-6/GB T17626.6: Electromagnetic compatibility (EMC) –Pare 4-6: Testing and measurement techniques–Immunity to Conducted disturbances, induced by radio-frequency field
Samples and Restrictions:
Various types of lighting equipment
Application:
Used for conducted immunity test for lighting equipment
Test Principle:
For the low frequency (150kHz ~ 80MHz / 230MHz) RF signal wavelength longer, EUT interconnect cable than the EUT itself easier to become an antenna to receive the electromagnetic field, so the radio frequency immunity test low frequency part of the conduction measurement. By injecting common-mode currents into the cables of the devices under test, the effects of E and H fields on the devices under test can be simulated. Different types of ports for the device under test, you can choose four kinds of injection:
CDN direct injection: for power cord (M-type CDN) and commonly used cables
Electromagnetic clamp injection: If you can not apply CDN, you can use the magnetic clamp.
Current Clamp Injection: CDN can not be used, and the length of the cable under test is too short, you need to use current clamp.
Direct injection method: through 100 ohm resistor diameter injected into the coaxial cable shield.
Structure:
Main test equipment: signal source, power amplifier, directional coupler, power meter, CDN network, EMC test software, etc.
Use Environment:
Power supply: AC380V±10% 50/60Hz
Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects
Technical Parameters:
Frequency Range | 150kHz~230MHz |
Highest Test Level | 10V |
Linear Power | 75W |
Amplifier Gain | 50dB |
Main Test Equipment | signal source, power amplifier, directional coupler, power meter, CDN network, EMC test software, etc. |
Test Environment | Shielded room (not included in this system, optional, or customer should prepare it) |
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...