| Payment Terms | L/C, T/T |
| Supply Ability | 100 Sets / Month |
| Delivery Time | 15 days |
| Packaging Details | Carton Box |
| Standard Clause | IEC60884 Clause 14.23.2 |
| Test Sample | Plug |
| Balancing Arm | 0-250mm |
| Hang Weight | 2.5N |
| Brand Name | Sinuo |
| Model Number | SN2107 |
| Certification | Calibration Certificate(cost additional ) |
| Place of Origin | China |
View Detail Information
Explore similar products
100mm Drop Tester EN 71-1 Toys 1KG Impact Strength Test Apparatus
IEC60884-1 Switch Life Tester For Insulation Parts Thermal Resistance 20N Ball
Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
Resistive Inductive Capacitive Load Cabinet for Switches Plugs and Sockets
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 100 Sets / Month |
| Delivery Time | 15 days | Packaging Details | Carton Box |
| Standard Clause | IEC60884 Clause 14.23.2 | Test Sample | Plug |
| Balancing Arm | 0-250mm | Hang Weight | 2.5N |
| Brand Name | Sinuo | Model Number | SN2107 |
| Certification | Calibration Certificate(cost additional ) | Place of Origin | China |
| High Light | switch endurance tester ,switch life testing machine | ||
IEC 60884-1 Clause 14.23.2 Plug Torque Test Apparatus
Product information:
Standard: Conforms to IEC 60884-1 2013 clause 14.23.2, IEC60065:2014 clause 15.4.1 and figure 11, IEC 60335-1 clause 22.3,etc.
Application: This device is use to test the strain force of insertion. A device provided with pins intended to be introduced into fixed socket-outlets shall not impose undue strain on these socket-outlets.
Test sample: fixed socket-outlet, plug-in equipment
Feature: According to the standard, measuring the torque force of the plug introduce into the socket.
Technical parameters:
1. Distance from the contact surface and the Axis of the surface: 8mm;
2. Balancing arm: 50-260mm;
3. Weight: 2.5N, can achieve 0.25Nm to 0.4Nm torque force;
4. Configure: one of each universal socket (suit for GB and BS plug), UL socket, European socket
Test process:
The equipment is inserted into a fixed socket-outlet complying with this standard, the socket-outlet is pivoted about a horizontal axis through the axis of the live socket-contacts at a distance of 8 mm behind the engagement face of the socket-outlet and parallel to this engagement face.
The additional torque which has to be applied to the socket-outlet in order to maintain the engagement face in the vertical plane shall not exceed 0,25 Nm.
Device structure:
| No.: | Name |
| 1 | Balance weight |
| 2 | Measuring bubble |
| 3 | Level bubble |
| 4 | Measuring weight |
| 5 | Height regulation screw |
| 6 | Support rod |
![]()
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
.gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr... .gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr...