| Payment Terms | L/C, T/T |
| Supply Ability | 100 Sets / Month |
| Delivery Time | 15 days |
| Packaging Details | Carton Box |
| Standard Clause | IEC60884 Clause 13.14 |
| Standard Figure | Figure 13 |
| Test Sample | Socket-outlets |
| Hang Weights | 5N*1pc |
| Test Cycle | 4 times |
| Test Time | 1 min |
| Brand Name | Sinuo |
| Model Number | SN2113 |
| Certification | Calibration Certificate(cost additional ) |
| Place of Origin | China |
View Detail Information
Explore similar products
100mm Drop Tester EN 71-1 Toys 1KG Impact Strength Test Apparatus
IEC60884-1 Switch Life Tester For Insulation Parts Thermal Resistance 20N Ball
Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
Resistive Inductive Capacitive Load Cabinet for Switches Plugs and Sockets
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 100 Sets / Month |
| Delivery Time | 15 days | Packaging Details | Carton Box |
| Standard Clause | IEC60884 Clause 13.14 | Standard Figure | Figure 13 |
| Test Sample | Socket-outlets | Hang Weights | 5N*1pc |
| Test Cycle | 4 times | Test Time | 1 min |
| Brand Name | Sinuo | Model Number | SN2113 |
| Certification | Calibration Certificate(cost additional ) | Place of Origin | China |
| High Light | switch endurance tester ,switch life testing machine | ||
IEC 60884-1 Figure 13 Device for Checking the Resistance to Lateral Strain 5N Force
Standard: IEC 60884-1 2013 clause 13.14, figure 13.
Application: This device is use to check socket-outlets shall withstand the lateral strain imposed by equipment likely to be introduced into them.
Test sample: Socket-outlets having ratings up to and including 16 A and 250 V.
Technical parameters:
| Test Plug | Made according to specific country's plug and socket requirements. |
| Hang weight | 5N*1pc |
| Test Times | Four times, socket-outlet turn through 90° after each test. |
Test process:
For socket-outlets having ratings up to and including 16 A and 250 V, compliance is checked by means of the device shown in figure 13.
![]()
Each specimen is mounted on a vertical surface with the plane through the socket-contacts horizontal. The device is then fully engaged and a weight hung on it such that the force exerted is 5 N.
The device is removed after 1 min and the socket-outlet is turned through 90° on the mounting surface. The test is made four times, the socket-outlet being turned through 90° after each engagement.
During the test the device shall not become disengaged from the socket-outlet.
![]()
![]()
(Different test plugs according to different country's standards can be customized)
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
.gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr... .gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr...
Get in touch with us
Leave a Message, we will call you back quickly!