| Payment Terms | L/C, T/T, Western Union, MoneyGram |
| Supply Ability | 100 Sets Per Month |
| Delivery Time | 3 Days |
| Packaging Details | Carton Box |
| Rod Diameter | φ40 mm |
| Rod Material | Stainless steel |
| Rod End Shape | Hemispherical |
| Handle Material | Nylon |
| Handle Length | 100 mm |
| Applied Standard | IEC60335-2-14 |
| Applied Clause | Clause 20.103 |
| Test Sample | Hand-held blender |
| Brand Name | Sinuo |
| Model Number | SN2210-25 |
| Certification | Calibration Certificate (Cost Additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
100mm Drop Tester EN 71-1 Toys 1KG Impact Strength Test Apparatus
IEC60884-1 Switch Life Tester For Insulation Parts Thermal Resistance 20N Ball
Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
Resistive Inductive Capacitive Load Cabinet for Switches Plugs and Sockets
Product Specification
| Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 100 Sets Per Month |
| Delivery Time | 3 Days | Packaging Details | Carton Box |
| Rod Diameter | φ40 mm | Rod Material | Stainless steel |
| Rod End Shape | Hemispherical | Handle Material | Nylon |
| Handle Length | 100 mm | Applied Standard | IEC60335-2-14 |
| Applied Clause | Clause 20.103 | Test Sample | Hand-held blender |
| Brand Name | Sinuo | Model Number | SN2210-25 |
| Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
| High Light | 40Mm Cylinder Rod Test Probe ,IEC 60335-2-14 Cylinder Rod Test Probe ,Hemispherical End Rod Test Probe | ||
IEC60335-2-14 Hand-held blenders φ40 mm Cylinder Rod Test Probe
Standard and Application:
The φ40mm cylinder rod meets the standard requirements of IEC 60335-2-14 Clause 20.103.
It is used to verify the hand-held blenders other than hand-held food mixers provided with a blender attachment shall incorporate a biased-off switch, its actuating member being positioned in a recess or otherwise guarded to prevent accidental operation.
Technical Parameters:
| Probe diameter | Φ40mm |
| Probe end shape | Hemispherical |
| Probe material | Stainless steel |
| Handle | Nylon |
Test Procedures and Operation:
Please refer to the relevant standards.
Take IEC 60335-2-14 Clause 20.103 as an example:
Compliance is checked by applying a cylindrical rod, having a diameter of 40 mm and a hemispherical end, to the actuating member of the switch. The test rod is applied with a foce not exceeding 5 N. The appliance shall not operate.
The test probe doesn’t have built-in force, if specific applied force required, the test probe should work together with a force gauge. At the end of our probe handle, there is a M6 thread hole to match the force gauge. Showing as following reference picture:
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
.gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr... .gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr...