| Payment Terms | L/C, T/T |
| Supply Ability | 30 Sets Per Month |
| Delivery Time | 20 Days |
| Packaging Details | Standard Exporting Boxed |
| Applied Standard | IEC 62368-1 |
| Applied Clause | 5.4.5.2 |
| Display Nethod | 5.7 LCD display |
| Output Range of AC Withstand | 100~5000V |
| Range Voltage of DC Withstand | 100~6000V |
| Output Range of Insulation Resistance | 100~1250V |
| Output Range of Ground Resistance | 2.0~32.0A |
| Communication Interface | Standard RS232 Match RS485 |
| Brand Name | Sinuo |
| Model Number | SN9368 |
| Certification | Calibration Certificate (Cost Additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
IEC 62368-1 Clause 9.6.2 Figure 47 Figure 48 Figure 49 Steel Aluminum Disc
IEC 62368-1 Annex T10 Centre Punch For Glass Fragmantation Test
IEC62368-1 Clause 4.8 Figure V.1 Jointed Test Probe For Equipment
IEC 62368-1 Test Equipment Annex T10 Glass Fragmentation Test Square Of 50mm
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 30 Sets Per Month |
| Delivery Time | 20 Days | Packaging Details | Standard Exporting Boxed |
| Applied Standard | IEC 62368-1 | Applied Clause | 5.4.5.2 |
| Display Nethod | 5.7 LCD display | Output Range of AC Withstand | 100~5000V |
| Range Voltage of DC Withstand | 100~6000V | Output Range of Insulation Resistance | 100~1250V |
| Output Range of Ground Resistance | 2.0~32.0A | Communication Interface | Standard RS232 Match RS485 |
| Brand Name | Sinuo | Model Number | SN9368 |
| Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
| High Light | IEC 62368-1 Electrical Safety Tester ,Clause 5.3.2 Electrical Safety Tester ,LCD Display Electrical Safety Tester | ||
IEC 62368-1 Clause 5.4.5.2 Electrical Safety Tester
Product information:
■The electrical safety tester conforms to IEC 62368-1 Clause 5.3.2, 5.4.5.2, the CCC,IEC,EN,VDE,BS,GS,UL etc. requirements of general electrical safety standards.
■5.7 LCD display with blue background, displaying data are intuitive and clear.
■Up to 200 groups of test conditions are memorized, each group has 8 test steps, and each group can be individually set for specifications and models for convenient query.
■Fast test speed: The instrument control core adopts ARM high-speed processor, and data processing is fully accelerated.
■High test accuracy: safety test accuracy up to 1.5%.
■The withstand voltage can be set up and down slowly, the upper and lower limit alarms, and the arc detection function.
■Digital closed-loop feedback control, automatic voltage regulation, automatic correction of output voltage/current, and not affected by external power grid fluctuations, ensuring the accuracy of the test.
■Ground resistance test items can choose voltage and resistance two judgment modes to meet the requirements of different countries/industry standards.
■Optional industrial computer system, after configuring the barcode scanner, it can realize the functions of scanning code self-starting test, scanning code adjustment test group, etc.. Bar code and test data are interconnected, and data is saved locally. Data management, analysis, and upload are realized.
■USB interface can realize data import and export.
Technical Parameters:
| Applied Standard | IEC 62368-1 | |
| Applied Clause | 5.4.5.2 | |
| AC Withstand Voltage | ||
| Output Voltage Setting Range | 100~5000V | |
| Output Voltage Setting Resolution | 1V | |
| Output Frequency | 50/60Hz | |
| Output Waveform | Sine Wave | |
| Ramp Up Time | 0.0~999s | |
| Ramp Down Time | 0.0~999s | |
| Resolution | 0.1s/1s | |
| Measurement Range | 0.100~40.00mA | |
| Test Accuracy | ± (1.5%×display value+5 words) | |
| Alarm Upper Limit Range | 0.10~40.00mA | |
| Alarm Lower Limit Range | 0.00~40.00mA | |
| Current Resolution | 0.01mA/0.001mA | |
| Testing Time | 0,0.5-999.9s (0 for continuous output) | |
| Resolution | 0.1s | |
| Arc Detection | 1~9 level (Level 9 is the highest sensitivity) | |
| DC Withstand Voltage | ||
| Output Voltage Setting Range | 100~6000V | |
| Output Voltage Accuracy | ± (1.5%×display value+5 words) | |
| Output Voltage Setting Resolution | 1V | |
| Ramp Up Time | 0.0~999s | |
| Ramp Down Time | 0.0~999s | |
| Resolution | 0.1s/1s | |
| Current Measurement Range | 0.100~10.00mA | |
| Current test Accuracy | ± (1.5%×display value+5 words) | |
| Alarm Upper Limit Range | 0.10~10.00mA | |
| Alarm Lower Limit Range | 0.00~10.00mA | |
| Current Resolution | 0.01mA/0.001mA | |
| Testing Time | 0,0.5-999.9s (0 for continuous output) | |
| Resolution | 0.1s | |
| Arc Detection | 1~9 level (Level 9 is the highest sensitivity) | |
| Insulation Resistance | ||
| Output Voltage Setting Range | 100~1250V | |
| Output Voltage Accuracy | ± (1.5%×display value+5 words) | |
| Output Voltage Setting Resolution | 1V | |
| Measurement Range | 1~2000MΩ | |
| Measurement Accuracy | ≤100MΩ | ± (5%×display value+3 words) |
| >100 MΩ | ± (8%×display value+8 words) | |
| Alarm Upper Limit Range | 0~2000MΩ(0 is ∞) | |
| Alarm Lower Limit Range | 1~2000MΩ | |
| Testing Time | 0,0.5-999.9s (0 for continuous output) | |
| Resolution | 0.1s | |
| Ground Resistance | ||
| Output Range | 2.0~32.0A | |
| Current Accuracy | ± (1.5%×display value+5 words) | |
| Measurement Range | 10~600mΩ | |
| Measurement Accuracy | ± (1.5%×display value+5 words) | |
| Alarm Upper Limit Range | 5~10A | 10~600mΩ |
| 11~25A | 10~300mΩ | |
| 26~32A | 10~200mΩ | |
| Alarm Lower Limit Range | 0~600mΩ | |
| Resolution Setting | 1 mΩ | |
| Testing Time | 0,0.5~999.9s (0 for continuous output) | |
| Resolution | 0.1s | |
| Leakage Current | ||
| Leak Type Setting | Dynamic Leakage. Static Leakage | |
| Human Body Network (MD Card) | Standard network, IEC 60990 Figure 4, it can customize any human body network | |
| Output Voltage Measurement Range | 50-280V | |
| Output Voltage Frequency | 45~65Hz | |
| Voltage Measurement Accuracy | ± (0.5%×display value+2words) | |
| Measurement Range | 0.050~20.00mA | |
| Measurement Precision | ± (2%×display value+0.02mA) | |
| Alarm Upper Limit Range | 0.050~20.00mA | |
| Alarm Lower Limit Range | 0.000~20.00mA | |
| Resolution | 0.01mA/0.001mA | |
| Time Range | 0,1.0~999.9s (0 for continuous output) | |
| Resolution | 0.1s | |
| Matching Specifications | ||
| Communication Interface | Standard RS232 Match RS485 | |
| External Control Method | PLC Interface Switch Signal | |
| Data Storage Method | USB Storage | |
| Dimension(W×H×D), mm | 435×150×550 | |
| Accessories (Standard) | Power cord×1, 32A Test Clamp×1, Test Box×1, Test Power Input Cable×1, Fuse×1, Instruction Manual×1 | |
| Accessories (Standard) | Alarm Light, Foot Switch | |
![]()
![]()
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
.gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr... .gtr-container-f7h2j9k1 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333333; line-height: 1.6; padding: 20px; box-sizing: border-box; border: none !important; } .gtr...