| Output voltage setting range | AC 200~5000V |
| Output voltage accuracy | ±(1.5%×setting+5digits) |
| Breakdown current measurement range | 0.10~100.0mA |
| Breakdown current measurement accuracy | ±(1.5%×setting+5digits) |
| Test time range | 1~300s |
| Test time resolution | 1s/step |
| Payment Terms | T/T, L/C, Western Union, MoneyGram |
| Supply Ability | 10 Sets Per Month |
| Delivery Time | 30 Days |
| Packaging Details | Plywood |
| Brand Name | Sinuo |
| Model Number | BF9636H |
| Certification | Calibration Certificate (Cost Additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
100mm Drop Tester EN 71-1 Toys 1KG Impact Strength Test Apparatus
IEC60884-1 Switch Life Tester For Insulation Parts Thermal Resistance 20N Ball
Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
Resistive Inductive Capacitive Load Cabinet for Switches Plugs and Sockets
Product Specification
| Output voltage setting range | AC 200~5000V | Output voltage accuracy | ±(1.5%×setting+5digits) |
| Breakdown current measurement range | 0.10~100.0mA | Breakdown current measurement accuracy | ±(1.5%×setting+5digits) |
| Test time range | 1~300s | Test time resolution | 1s/step |
| Payment Terms | T/T, L/C, Western Union, MoneyGram | Supply Ability | 10 Sets Per Month |
| Delivery Time | 30 Days | Packaging Details | Plywood |
| Brand Name | Sinuo | Model Number | BF9636H |
| Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
| High Light | High Voltage Insulation Flash Tester ,5000V High Voltage Insulation Flash Tester | ||
High Voltage Insulation Flash Tester
Product overview:
■Meet the test requirements of general electrical safety standards such as IEC 60884-1:2013 clause 17, etc
■ Up to 100 groups of test condition memory, model of each group can be set, easy to find, test data can be saved via USB(optional)
■ Voltage ramp-up and ramp-down functions to meet the requirements of new industry standards;
■ Breakdown current upper and lower limit preset, intelligent judgment;
■ Digital closed-loop feedback control mode, automatic voltage regulation mode, automatic correction of output voltage/current, and not affected by the external power grid, ensuring the accuracy of the test
■ High-definition LCD display and simple panel operation
Technical parameter:
| Model | BF9636H |
| Test Contents | AC and DC withstand voltage, insulation resistance |
| Data storage method | USB (optional) |
| External interface | Alarm LAMP, PLC, RS-232 |
| AC withstand voltage | |
| Output voltage setting range / accuracy |
AC 200~5000V ±(1.5%×setting+5digits) |
| Breakdown current measurement range / accuracy |
0.10~100.0mA ±(1.5%×setting+5digits) |
| Breakdown current preset alarm range |
Upper limit :0.1~100.0mA; Lower limit :0.00~5.00mA |
| Short-circuited current capacity | ≥200mA (the device will enter into protection status when short-circuited current exceeds 200mA) |
| Test time range / resolution | 1~300s 1s/step |
| DC withstand voltage | |
| Output voltage setting range / accuracy | DC 200~5000V ±(1.5%× setting +5 digits ) |
| Breakdown current measurement range / accuracy | 0.10~10.00mA ±(1.5%×display+5 digits) |
| Breakdown current preset alarm range | Upper limit: 0.10~10.00mA; lower limit: 0.00~5.00mA |
| Test time range / resolution | 1~300s 1s/step |
| Insulation resistance | |
| Output voltage setting range / accuracy | DC500/1000V ±(1.5%× reading +5 digits ) |
| Insulation resistance measurement range / accuracy |
1~2000MΩ: ≤100MΩ:± (5%×display+3 digits ) >100 MΩ:± (8%× display +8 digits) |
| Insulation resistance alarm setting range |
Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ |
| Test time range / resolution |
1~300s 1s/step |
| Equipment dimensions | 435MM(W)*150MM(H)*550MM(D) |
| Equipment weight | Approx. 30KGS |
| Equipment accessories | Power cord*1, high voltage probe*1, test wire*1, fuse*1 |
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ... We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ...