China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester
China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester

  1. China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester
  2. China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester
  3. China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester
  4. China IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester

IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T,Western Union
Alarm range 60/34V
Applied clause Clause 8.2.7
Delivery Time 7 business days
Residual range 5~150V
Testing time 1s
Test impedance ≥ 100 MΩ
Supply Ability 15 sets/month
Output power 2000W
Applied standard IEC 60598-1,etc.
Packaging Details Export package
Output voltage AC 0~242V
Model Number SN-SY2000W
Certification Calibration certificate(cost additionally)
Brand Name SINUO
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union Alarm range 60/34V
Applied clause Clause 8.2.7 Delivery Time 7 business days
Residual range 5~150V Testing time 1s
Test impedance ≥ 100 MΩ Supply Ability 15 sets/month
Output power 2000W Applied standard IEC 60598-1,etc.
Packaging Details Export package Output voltage AC 0~242V
Model Number SN-SY2000W Certification Calibration certificate(cost additionally)
Brand Name SINUO Place of Origin CHINA
High Light Portable Luminaire Residual Voltage Tester ,IEC 60598-1 Luminaire Residual Voltage Tester
IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester
The Residual Voltage Tester complies with clause 8.2.7 of IEC 60598-1:2020 and multiple international standards including IEC 60335-1 Clause 22.5, IEC 60065 Clause 9.1.6, IEC 60601-1, IEC/EN 60598-1 Clause 8.2.7, and IEC 60950-1.
Key Features
  • Performs power interruption testing at peak supply voltage for reliable, repeatable measurement results
  • Test impedance ≥ 100 MΩ, fully compliant with impedance requirements for residual voltage and capacitance measurements
  • Comprehensive testing capabilities including:
    • Residual voltage measurement between power terminals
    • Residual voltage measurement between power terminals and equipment enclosure
    • Residual voltage and capacitance testing of externally accessible capacitors
  • Supports both manual and automatic test modes
    • Manual mode: Phase-to-phase testing with 10 consecutive measurements per pole combination
    • Automatic mode: Sequential three-pole combination tests with 10 measurements per combination
  • Automatically records and retains highest measured residual voltage value
  • Triggers alarm when residual voltage exceeds 60 V or 34 V
IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester product image
Technical Parameters
Parameter Specification
Output voltage AC 0~242V
Residual voltage testing range 5~150V
Testing time 1s
Testing impedance 100 MΩ
Testing alarm range 60/34V
Output power 2000W
Testing discrimination Audible and visual alarm, simultaneously cutting off voltage
IEC 60598-1 Clause 8.2.7 Requirements
  • Luminaires (with exceptions) incorporating capacitors exceeding 0.5 μF must include a discharge device ensuring voltage across the capacitor does not exceed 50 V within 1 minute after disconnection at rated voltage
  • Portable luminaires connected via plug, track adaptors, or luminaires with accessible supply connectors containing capacitors exceeding 0.1 μF (or 0.25 μF for luminaires rated below 150 V) must discharge to ≤34 V within 1 second after disconnection
  • Other plug-connected luminaires with capacitors exceeding 0.1 μF (or 0.25 μF for luminaires rated below 150 V) and track adaptors must discharge to ≤60 V RMS within 5 seconds after disconnection
  • Testing must be conducted with the lamp in circuit when measuring voltage from compensation capacitors if it leads to more onerous results
  • Residual voltage measurements are performed on individual luminaires, even when installed in multiple luminaire systems
IEC 60598-1 Clause 8.2.7 Portable Luminaire Residual Voltage Tester technical specifications

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    2000000 USD-3000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ... We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement