Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"IEC60238 Cl. 16.4 Figure 6 Lampholders Mechanical Strength Torque Test Apparatus","imgUrl":"https:\/\/img.chinax.com\/nimg\/5c\/91\/da40aad0e6a3e34bd8d98a11e1df-200x200-1\/iec60238_cl_16_4_figure_6_lampholders_mechanical_strength_torque_test_apparatus.jpg","attrs":{"Minimum Order Quantity":"1","Model Number":"SN2805","Warranty":"1 year","Place of Origin":"China"}}
{"title":"IEC 60061-3 Lamp Caps and Holders Gauges for Control of Interchangeability and","imgUrl":"https:\/\/img.chinax.com\/nimg\/f9\/d5\/2481c673439abe8eb4e6eafd2a64-200x200-1\/iec_60061_3_lamp_caps_and_holders_gauges_for_control_of_interchangeability_and_safety.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN991","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
{"title":"Thermal Durability Test Led Testing Equipment Large Luminaires Temperature Aging","imgUrl":"https:\/\/img.chinax.com\/nimg\/08\/c1\/49f11f47040cf21feaf4cec0c18e-200x200-1\/thermal_durability_test_led_testing_equipment_large_luminaires_temperature_aging_room.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN998","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
{"title":"IEC 60598-1 PLC Control Led Testing Equipment Luminaries Adjusting Devices 360\u00b0","imgUrl":"https:\/\/img.chinax.com\/nimg\/20\/e8\/9299666b2efba30c3b64afe6342d-200x200-1\/iec_60598_1_plc_control_led_testing_equipment_luminaries_adjusting_devices_360_c2_b0_movement.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN996","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
{"title":"IEC 60598-1 Cu and Zn Test Chain Short-circuit Protection for SELV Parts","imgUrl":"https:\/\/img.chinax.com\/nimg\/bc\/59\/803bba6c8482dcd15e5162466e7f-200x200-1\/iec_60598_1_cu_and_zn_test_chain_short_circuit_protection_for_selv_parts_temperature_rising_testing.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN992","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
{"title":"Stepless Adjustment Led Testing Equipment Semi - Luminaires Bending Movement","imgUrl":"https:\/\/img.chinax.com\/nimg\/36\/cc\/6d0f8b7ca6f08088ba39f8271281-200x200-1\/stepless_adjustment_led_testing_equipment_semi_luminaires_bending_movement_test.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN995","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
{"title":"IEC 60598-1 Led Testing Equipment Screwed Glands Torque Test 1.5-30N.m Digital","imgUrl":"https:\/\/img.chinax.com\/nimg\/f7\/cb\/3aebe422a08c7f691f1a2cded20a-200x200-1\/iec_60598_1_led_testing_equipment_screwed_glands_torque_test_1_5_30n_m_digital_spanner.jpg","attrs":{"Brand Name":"Sinuo","Model Number":"SN994","Certification":"Calibration Certificate (Cost Additional)","Place of Origin":"China"}}
Developed per IEC 60238:2016+A1:2017+A2:2020 Clauses 16.2, 16.4 and Figure 6, this torque testing equipment verifies the mechanical performance and service life of lamp holders.
Test Procedure
Replacing Lamp Holder Gauge: Choose the matching gauge based on the lamp base type. Loosen the fixing screws on the device, take off the existing lamp holder gauge and install the new one for testing.
Securing the Test Sample: Mount the lamp base onto the dedicated fixture. Loosen the fixture screws and adjust its vertical position to align the lamp holder gauge with the center of the lamp base. Once positioned correctly, tighten the screws to lock the fixture in place.
Conducting the Test: Wrap the steel wire rope around the torque disc. If the lamp holder is assembled onto the lamp base via clockwise rotation, wrap the rope clockwise; otherwise, wrap it counterclockwise. Attach specified weights and apply torque continuously for 1 minute.
Standard Torque Values
0.3 Nm for E5 lamp holders
0.3 Nm for E10 lamp holders
0.5 Nm for E14 candle lamp holders with threaded entry fixing
1.2 Nm for E14 candle lamp holders with outer shell clamping
1.2 Nm for other E14 lamp holders
2 Nm for E27 lamp holders
4 Nm for E40 lamp holders
Weight Configuration
Specification
Torque
Weight Configuration
E5
0.3 Nm
6N
E10
0.3 Nm
6N
E14 (Threaded Fixing)
0.5 Nm
6N+4N
E14 (Outer Shell Fixing)
1.2 Nm
6N+4N+14N
E14 (Other)
1.2 Nm
6N+4N+14N
E27
2 Nm
6N+4N+14N+16N
E40
4 Nm
6N+4N+14N+16N+40N
Perform the test in two separate runs. First, clamp the sample by its outer casing. Second, secure it via the threaded inlet, dome or backplate, as applicable to the lamp holder design.
Upon completion of testing, the sample must not sustain any damage or defects that would affect its normal operation.