| Payment Terms | T/T |
| Supply Ability | 20 sets per month |
| Delivery Time | 30 Days |
| Packaging Details | Plywood |
| Test Station | Can be customized |
| Output Voltage | 0~300V |
| Output Current | 0~80A |
| Power meter | 0~24KW |
| Capacitive load | 70uf, 140uf, 7.3uf |
| Load Type | Resistive, inductive, capacitive |
| Brand name | Sinuo |
| Warranty time | One year |
| Brand Name | Sinuo |
| Model Number | SN224 |
| Certification | Calibration Certificate (Cost Additional) |
| Place of Origin | China |
View Detail Information
Explore similar products
Automotive Plugs Vehicle Connectors Cable Anchorage Pull Force and Torque Test
Electric Car Accessories Mechanical Strength 1~6J Energy Pendulum Impact test
IEC 62196-1 Rewireable Plugs And Vehicle Connector Drop Testing Equipment
IEC 62196 11000N Vehicle Connectors and Plugs Drive Over Testing Equipment
Product Specification
| Payment Terms | T/T | Supply Ability | 20 sets per month |
| Delivery Time | 30 Days | Packaging Details | Plywood |
| Test Station | Can be customized | Output Voltage | 0~300V |
| Output Current | 0~80A | Power meter | 0~24KW |
| Capacitive load | 70uf, 140uf, 7.3uf | Load Type | Resistive, inductive, capacitive |
| Brand name | Sinuo | Warranty time | One year |
| Brand Name | Sinuo | Model Number | SN224 |
| Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
| High Light | 80A Load Cabinet ,Switches Plugs Load Cabinet | ||
IEC 62196 80A Load Cabinet for Switches Plugs and Sockets Breaking Capacity Test
Standards & Clauses:
This load cabinet conforms to IEC 62196-1:2020 clause 22. It is used to process breaking capacity test for plug, socket, switch, connector, relay and other parts. The load cabinet has single-phase power output and single-phase load input, and the load can be divided into resistive, inductive or capacitive loads.
Application:
Used to provide adjustable load voltage, current and power factor during mechanical-electrical contact system test. it is suitable for breaking capacity and normal operation endurance test of switches, plugs and socket-outlets for household and similar fixed electrical installations, and electrical stress test for luminaries and other similar tests. This series of resistive, inductive, capacitive load cabinets should work with Sinuo's plug, socket and switch endurance test equipment.
Test station quantity can be customized:
![]()
![]()
Technical Parameters:
| No.: | Item | Parameters |
| 1 | Power supply | Single phase AC220V/60Hz with ground wire |
| 2 | Channel | 1 channel |
| 3 | Digital voltmeter | 0~300V, accuracy ±0.5% |
| 4 | Digital ammeter | 0~82A, accuracy ±0.5% |
| 5 | Digital display power meter | 0~24KW, accuracy ±0.5% |
| 6 | Digital display power factor meter | 0.2~0.999, accuracy ±0.5% |
| 7 | Load mode | Resistive, inductive, capacitive three in one, switchable |
| 8 | Capacitive load | 70uf, 140uf, 7.3uf can be switchable |
| 9 | Load output mode | Each power (continuous) / interval power can be switchable |
| 10 | Timer | 0~9999 times, can be preset |
| 11 | Load power capacity | Single 24KVA |
| 12 | Upper limit of output current | 82A, when it exceeds 82a, it will cut off automatically |
| 13 | Operating environment | Temperature: + 5 ~ + 40 ℃; relative humidity: (20 ~ 90)% RH; atmospheric pressure: 80 ~ 106kpa; no severe shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gas, good heat dissipation. |
Test Principle:
The output voltage, output current and power factor can be adjusted through the circuit combination.
Structure:
The load cabinet uses an integral steel structure frame and a Toyota white seal plate. The control panel is in the upper part of the equipment, there are external power supply switch, ammeter, voltmeter and power meter, power display instrument, load power supply switch, status indicators, start and stop buttons, capacitance switch, load type switch and alarm on the control panel. The voltage, current and power factor regulators are on the lower part of the equipment. Each load station has a three-in-one function of resistive, inductive and capacitive (fluorescent) load, which can be switched by a transfer switch. The interior of the load cabinet is cooled by strong wind convection. There are terminals at the bottom of the back of the load cabinet, which can be connected to the switch plug socket-out normal operation endurance test equipment through the cables to output current, voltage and power during the breaking capacity testing.
Use Environment:
Power supply:Single phase AC220V/60Hz with ground wire, 24 KVA/station or meet client's local power supply requirements
Use place: atmospheric pressure 80 ~ 106kpa; ambient temperature 5 ~ 40 ° C; relative humidity (20 ~ 80) % RH; no vigorous shaking, no vibration, no electromagnetic interference, no dust, no explosive and no corrosive gas, with good heat dissipation
![]()
Company Details
Business Type:
Manufacturer
Total Annual:
2000000 USD-3000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ... We Turn Testing Standards into Working Test Systems Sinuo designs and manufactures testing equipment and integrated laboratory systems for manufacturers, quality inspection institutes, independent laboratories, research organizations and universities. With more than 15 years of testing-equipment ...