China factories

Chat Now Send Email
China factory - Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co. , Limited

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System
China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System

  1. China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System
  2. China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System
  3. China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System
  4. China IEC 62552 Two Stations Refrigerator Energy Efficiency Test System

IEC 62552 Two Stations Refrigerator Energy Efficiency Test System

  1. MOQ: 1
  2. Price: Tailored
  3. Get Latest Price
Payment Terms T/T
Supply Ability 1 Set Per Month
Delivery Time 2 Months
Packaging Details Plywood
Applied Standards IEC 62552,etc.
Applied UUT Refrigerator & Freezers
Temperature Range 0°C to +50°C ±0.3°C
Humidity Range 35%RH to 93%RH ± 3.0%RH
Test Station 2 stations
Test Capacity Range 210L~550L
Control Method Computer & software
Output Power 5KVA
Brand Name Sinuo
Model Number SN332-10
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 1 Set Per Month
Delivery Time 2 Months Packaging Details Plywood
Applied Standards IEC 62552,etc. Applied UUT Refrigerator & Freezers
Temperature Range 0°C to +50°C ±0.3°C Humidity Range 35%RH to 93%RH ± 3.0%RH
Test Station 2 stations Test Capacity Range 210L~550L
Control Method Computer & software Output Power 5KVA
Brand Name Sinuo Model Number SN332-10
Certification Calibration Certificate (Cost Additional) Place of Origin China
IEC 62552 Two Stations Refrigerator Energy Efficiency Test System
System Overview

ISO 15502 Refrigerator Freezer Energy Efficiency Performance Test Chamber provides a stable and reliable environment for refrigerator type testing and development. The system can simultaneously accommodate 2 refrigerators for comprehensive testing under various standard operating conditions and simulated usage scenarios.

Key Features:

  • Each workstation equipped with 20-channel thermocouple temperature sensors
  • Three power supply options per station (DC, AC variable frequency, and mains)
  • Leakage protection switches and contactors for safety
  • Advanced energy analysis with variable frequency compressor technology
  • Ultrasonic humidification reducing energy consumption by approximately 40%
IEC 62552 Refrigerator Energy Efficiency Test System Laboratory Setup
Technical Specifications

Compliance Standards: IEC 62552:2015

Test Capabilities:

  • Refrigeration rate testing
  • Storage temperature analysis
  • Working coefficient measurement
  • Power consumption monitoring
  • Freezing capacity assessment
  • Load recovery testing
  • Ice-making capacity evaluation
  • Condensation testing

Laboratory Structure:

  • B1-grade 100mm thick polyurethane foam insulation panels
  • Top-supply and dual-side return air system
  • 0.6mm thick steel plate interior/exterior surfaces
  • Aluminium perforated panel ceiling
  • External dimensions: 4000mm W * 4000mm D * 3200mm H
  • Single-leaf door with electrically heated frame and observation window
  • 2 wooden test benches (2300mm W * 1200mm D * 2300mm H)
Temperature Adjust/Control Humidity Adjust/Control
0℃ No humidity requirement No
10℃ 45~93%RH No
16℃ 45~93%RH
32℃ 45~93%RH
43℃ 45~93%RH
50℃ No humidity requirement No

Performance Parameters:

  • Temperature range: 0°C to +50°C ±0.3°C
  • Humidity range: 35%RH to 93%RH ±3.0%RH (controlled between 10°C and 45°C)
  • Wind speed: less than 0.25 m/s
  • Heating/cooling rate: -10°C to 50°C transition in less than 90 minutes
  • Vertical temperature gradient: less than 0.88°C/m
Measurement & Control Systems

Temperature & Humidity Control:

  • Temperature controller: SR93
  • Control range: 0°C to 50°C
  • Control accuracy: ±0.3°C
  • Humidity control range: 35% to 95% RH
  • Humidity control accuracy: ±3% RH

Temperature Measurement:

  • Thermocouples: 2 * 0.254 mm (Ø), Omega, 20 points per station
  • Measurement accuracy: ±0.3°C (-5°C to 80°C)
  • Isothermal terminals: American Omega SMP-MF dedicated sockets
  • Temperature parameter acquisition: Yokogawa GM10, 40 channels
Temperature measurement and control system components

Computer System:

  • Intel i7 processor
  • 8GB RAM
  • 1TB hard drive
  • 27-inch LCD monitor
  • Windows-based test software with English interface
Air Conditioning & Control Systems

Air Conditioning Unit:

  • Water-cooled compression condensing unit with stepless control
  • 3HP+3HP Copeland/Danfoss compressors
  • Copper heat exchanger and coil
  • Stainless steel electric heater with solid-state relay control
  • Ultrasonic humidifier with automatic water supply
  • Centrifugal fan system
  • All stainless steel air conditioning cabinet (1.0mm)

Control System:

  • Temperature and humidity controller: SR93
  • Programmable logic controller: Mitsubishi PLC
  • Touch screen: Mitsubishi 10-inch
  • Solid-state relays: Ximaden or equivalent reputable brands
  • Circuit breakers and contactors: Schneider brand
  • Comprehensive alarm and protection functions
Air conditioning and control system components
Quality & Safety Standards

Construction & Materials:

  • Stainless steel air handling cabinet (≥1.0mm thickness)
  • Isothermal terminal boxes constructed of 1.2mm thick stainless steel
  • Control cabinet with 1.2mm thick steel plates
  • All instruments and components are new, high-quality with valid warranties
  • Professional cable management with dedicated labeling

Safety Features:

  • Combustible gas alarm system (0-1000 ppm or 0-100% LEL range)
  • Protective devices for abnormal temperature, pressure, water level, voltage, and current
  • Electrical safety design compliant with national standards
  • Reliable grounding with 2.5mm² copper-core wire
  • 72-hour continuous operation capability without defrosting
Software Capabilities

The laboratory testing software provides comprehensive functionality for refrigerator performance evaluation:

  • Latest standard testing software compliant with IEC 62552
  • Adjustable data collection rate (3 to 30 seconds)
  • Comprehensive testing functions including:
    • Power consumption analysis
    • Storage temperature monitoring
    • Freezing capacity assessment
    • Cooling rate measurement
    • Temperature recovery testing
    • Ice production capacity evaluation
    • Voltage fluctuation analysis
  • Excellent stability and reliability
Laboratory testing software interface and capabilities

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    800000-1500000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement