China 9999 Counts Display Auto Ranging Digital Multi meter 10MΩ 600V DC
China 9999 Counts Display Auto Ranging Digital Multi meter 10MΩ 600V DC

  1. China 9999 Counts Display Auto Ranging Digital Multi meter 10MΩ 600V DC

9999 Counts Display Auto Ranging Digital Multi meter 10MΩ 600V DC

  1. MOQ: 10pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, Western Union,Paypal,L/C
Supply Ability 50000pcs/month
Delivery Time 5-35days
Packaging Details 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg
product name Portable Digital Multimeter
Model CHX-DM033
DC voltage Accuracy ±(0.5% of reading + 5 words)
Input impedance 10MΩ
Maximum input voltage 600V DC or 600V AC (rms)
Frequency range 40 ~ 1000Hz True RMS
Frequency response 10 ~ 10MHz
Brand Name CHX
Model Number CHX-DM033
Certification CE, RoHS
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,Paypal,L/C Supply Ability 50000pcs/month
Delivery Time 5-35days Packaging Details 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg
product name Portable Digital Multimeter Model CHX-DM033
DC voltage Accuracy ±(0.5% of reading + 5 words) Input impedance 10MΩ
Maximum input voltage 600V DC or 600V AC (rms) Frequency range 40 ~ 1000Hz True RMS
Frequency response 10 ~ 10MHz Brand Name CHX
Model Number CHX-DM033 Certification CE, RoHS
Place of Origin CHINA
High Light 10MΩ Auto Ranging Digital MultimeterAuto Ranging Digital Multi meter10MΩ Auto Ranging Digital Multi meter

9999 Counts Display Auto Ranging Digital Multi meter

 

 

Function selection


1) In the voltage range, press "FUNC" key, will be in the AC voltage, DC voltage cycle between the switch.
2) In the resistor, diode, buzzer file, press the "SEL" button, will be in the resistance, on-off detection, diode three file cycle switch.
3) In the frequency, duty cycle file, press the "FUNC" key, will be in the frequency, duty cycle between the switch.
4) In the temperature range, press the "FUNC" key, will be in degrees Celsius and Fahrenheit cycle switch.
5) In the current file, press "FUNC" key, will be in the AC current, DC current cycle between the switch

 

backlight and lighting


1) During the measurement, if the ambient light is too dark, the reading is difficult, press the " " button for more than 2 seconds, turn on the backlight and the lights, and turn off automatically after about 15 seconds.
2) During this period, if the " " button for more than 2 seconds will manually turn off the backlight and lighting.
Backlight and lighting of the luminous body for the LED, the working current is large, although the instrument has a timer circuit (timing time of about 15 seconds), but often use the backlight and lighting will shorten the battery life, so unnecessary Of the circumstances, should be used as little as possible backlight.

 

 

Technical indicators
 
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
 
 
 
3.2.2 DC voltage

Range Resolution Accuracy
6V 0.001V ±(0.5% of reading + 5 words)
60V 0.01V
600V 0.1V ±(0.8% of reading + 5 words)

- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
3.2.3 AC voltage
 

Range Resolution Accuracy
6V 0.001V ±(0.8% of reading + 3words)
60V 0.01V
600V 0.1V ±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
 
3.2.4 Alternating current
 

Range Resolution Accuracy
600.0uA 0.1uA ±(1.5% of reading +10words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.5% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
 
3.2.5 DC
 

Range Resolution Accuracy
600.0uA 0.1uA ±(1.0% of reading +5words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.0% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 
 
3.2.6 Frequency
 

Range Resolution Accuracy
9.999Hz 0.001Hz ±(1.0% of reading +3words)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99KHZ 0.01kHZ
999.9KHZ 0.1KHZ
9.999MHZ 0.001MHZ

- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
 
 
3.2.7 Duty cycle
 

Range Resolution Accuracy
0.1 – 99.9% 0.1% ± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)
 
 

Resistance
 

Range Resolution Accuracy
600W 0.1W ±(0.8% of reading +3words)
6kW 0.001kW
60kW 0.01kW
600kW 0.1kW
6MW 0.001MW ±(1.2% of reading +3words)
60MW 0.01MW

- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
 
 

Transistor test

 

Range Description Test Conditions
hFE The display reads the approximate value of hFE(0~1000) Base current of about 10uA; Vce about 2.8V

 

 

Capacitance

 

Range Resolution Accuracy
9.999nF 0.001nF ±(4.0% of reading +3words)
99.99nF 0.01nF
999.9nF 0.1nF
9.999mF 0.001mF
99.99mF 0.01mF
999.9mF 0.1mF
9.999mF 0.001mF ±(5.0% of reading +3words)
99.99mF 0.01mF Not calibrated

- Overload protection: 250V DC or AC (rms)

 

 

Temperature test

 

Range Accuracy Resolution
-20℃-300℃ ±(1.0%+4d) 1℃
301℃-1000℃ ±(1.9%+5d) 1℃
-4℉-600℉ ±(1.2%+6d) 1℉
601℉-1832℉ ±(1.9%+6d) 1℉

- Overload protection: 250V DC or AC (rms)

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    3000000-8000000

  • Employee Number:

    80~100

  • Ecer Certification:

    Active Member

Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...

+ Read More

Get in touch with us

  • Reach Us
  • SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
  • 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China
  • MsEmily Tan
  • 86 13823390435
  • https://www.smart-multimeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement