Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Hall Effect Current Sensor HBC100LAHS5 100A Galvanic Isolation for Variable","imgUrl":"https:\/\/img.chinax.com\/nimg\/86\/76\/fb257e7ab2fbd2afd87cafb5c0ec-200x200-1\/hall_effect_current_sensor_hbc100lahs5_100a_galvanic_isolation_for_variable.jpg","attrs":{"Model Number":"HBC100LAHS5","Payment Terms":"T\/T","Input":"100A","Certification":"RoHS"}}
{"title":"Flexible Assembly Hall Effect Current Sensor Module 40A Magnetic Balance","imgUrl":"https:\/\/img.chinax.com\/nimg\/1b\/ec\/81654b8ad8bf343aefe3ac1165e6-200x200-1\/flexible_assembly_hall_effect_current_sensor_module_40a_magnetic_balance.jpg","attrs":{"Certification":"CE, RoHS, ISO","Minimum Order Quantity":"Negotiation","Packaging Details":"Carton","Delivery Time":"4~8 Weeks"}}
{"title":"2000A Rated Input High Current Hall Effect Sensor Epoxy Encapsulated Housing","imgUrl":"https:\/\/img.chinax.com\/nimg\/12\/0e\/9de13f96d1469bed604bd9f3523c-200x200-1\/2000a_rated_input_high_current_hall_effect_sensor_epoxy_encapsulated_housing.jpg","attrs":{"Brand Name":"Shinhom","Model Number":"HKC-K","Place of Origin":"China","Certification":"RoHS"}}
{"title":"Blue Hall Effect Current Sensor , Hall Effect Current Transformer PCB Mounting","imgUrl":"https:\/\/img.chinax.com\/nimg\/90\/2b\/91adcba6eb36ec35078b9a3fd283-200x200-1\/blue_hall_effect_current_sensor_2c_hall_effect_current_transformer_pcb_mounting.jpg","attrs":{"Certification":"CE, RoHS, ISO","Minimum Order Quantity":"Negotiation","Packaging Details":"Carton","Delivery Time":"4~8 Weeks"}}
{"title":"Customized Hall Effect Based Current Sensor For UPS \/ SMPS Current Monitoring","imgUrl":"https:\/\/img.chinax.com\/nimg\/54\/df\/cda58c2f7ab0887ac84e3b1b0c7b-200x200-1\/customized_hall_effect_based_current_sensor_for_ups_2f_smps_current_monitoring.jpg","attrs":{"Certification":"RoHS","Minimum Order Quantity":"5000PCS","Packaging Details":"Carton","Delivery Time":"4~8 Weeks"}}
{"title":"Mount Easily Hall Effect Current Sensor ,10mA Hall Effect Current Transducer","imgUrl":"https:\/\/img.chinax.com\/nimg\/62\/75\/abbb36bfc66dc3b47aa8cd1365f1-200x200-1\/mount_easily_hall_effect_current_sensor_2c10ma_hall_effect_current_transducer.jpg","attrs":{"Certification":"RoHS","Minimum Order Quantity":"Negotiation","Packaging Details":"Carton","Delivery Time":"4~8 Weeks"}}
{"title":"Accurate Hall Current Sensor High Accuracy Grade Convenient Installation","imgUrl":"https:\/\/img.chinax.com\/nimg\/bc\/68\/e96e165b9052771d0074a244e935-200x200-1\/accurate_hall_current_sensor_high_accuracy_grade_convenient_installation.jpg","attrs":{"Brand Name":"Shinhom","Model Number":"HBC1000LF","Certification":"RoHS","Place of Origin":"China"}}
The HBC100LAHS5 closed-loop Hall effect current sensor uses a closed-loop (compensation) principle, providing electrical isolation between the primary and secondary circuits. It accurately measures DC, AC, or pulse currents with a measuring range of 0-100A and a turns ratio of 1:1200. The product has a supply voltage of +5V±5% and a rated output voltage of ±0.625V±0.5%. It offers high accuracy and easy installation. It is widely used in inverters, AC/DC variable speed drives, UPS, switching power supplies, photovoltaic current sensing, new energy combiner box measurement, wind power current sensing, EV charging equipment current sensing, drive-by-wire automotive applications, household appliance frequency conversion, automatic air compressors, hybrid battery pack current sensing, and automotive electric power steering systems.
Features:
Closed- loop
Operating currents: 0 to 100A
Power supply: +5V±5%
Rated output voltage: ±0.625V±0.5%
High accuracy grade
Mount easily
Applications:
Inverter applications
AC/DC variable-speed drive
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Photovoltaic (PV) current applications
New Energy Combiner Box Measurement
Wind Power Industry Current Detection
Electric vehicle charging equipment current sensing
Automible By-wire application
Household appliance frequency conversion
Auto air conpressor application
Hybrid battery pack current sensing
Automobile electrical power steering system application
ELECTRICAL DATA:
HBC100LAHS5
Rated input current(Ipn)
100
A
Test current range(Ip)
±240
A
Turns ratio(Np/Ns)
1:1200
T
Rated output voltage
±0.625±0.5%
V
Supply voltage
+5±5%
V
Consumption current
20+ Ip *( Np/Ns)
mA
Offset voltage
2.5±0.4%
V
Reference voltage(VR)
2.5±0.5%
V
External reference voltage
2.0-2.8
V
Offset voltage Drift
≤±0.1
mV/℃
Output voltage Drift
≤±0.05
mV/℃
LinearityIp=0-±Ipn)
≤±0.2
%FS
Class
≤±1.0
%
di/dt
>100
A/µS
Response time(100A/µS, 10%~90%)
≤1
µS
Bandwidth(-3db)
DC~100
KHZ
Insulation voltage(50HZ,AC,1min)
5.0
KV
Operating Temperature(TA)
-40~+85
℃
Storage Temperature(TS)
-40~+105
℃
Gross weight(M)
22
g
Notes: Product specifications can be customized
FAQ
Q: What is the working principle of a closed-loop Hall effect sensor?
A: A closed-loop Hall effect sensor uses a Hall element to detect the magnetic field generated by the measured current. The output signal drives a compensation coil to generate an opposing magnetic field, bringing the net magnetic flux in the core to zero. The compensation current is proportional to the measured current, providing high-accuracy, low-temperature-drift measurement results.
Q: What does a turns ratio of 1:1200 mean?
A: A turns ratio of 1:1200 means the ratio of primary current to secondary compensation current is 1:1200. For example, a 100A primary current corresponds to approximately 83.3mA secondary compensation current, which is converted to a ±0.625V voltage output through the built-in resistor.
Q: What new energy applications is this product suitable for?
A: This product is suitable for photovoltaic current sensing, new energy combiner box measurement, wind power current sensing, EV charging equipment current sensing, and hybrid battery pack current sensing in the new energy field.
Q: How to apply for samples? What is the lead time?
A: You can submit a sample application through our website or email. Please provide your company information and target model. Samples are free of charge and will be shipped within 3-5 working days. Mass order lead time is generally 2-8 weeks.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller,Other
Year Established:
2002
Total Annual:
5000000-6000000
Employee Number:
600-~800
Ecer Certification:
Verified Supplier
Shaanxi SHINHOM Enterprise Co.,Ltd is one large-sized key enterprise in producing magnetic components and supplying OEM`high quality magnetics components in China ,It has been approved for the certification ISO9001&QS9000.Shinhom has grown rapidly by supplying high quality magnetic ... Shaanxi SHINHOM Enterprise Co.,Ltd is one large-sized key enterprise in producing magnetic components and supplying OEM`high quality magnetics components in China ,It has been approved for the certification ISO9001&QS9000.Shinhom has grown rapidly by supplying high quality magnetic ...