| Supply Ability | 10000/MONTH |
| Current range | 5~630A |
| Customizable | Yes |
| Delivery Time | 4~8 Weeks |
| Frequency | 50Hz-2KHz |
| Payment Terms | T/T |
| Output | 0.333V(AC) or 0-500mA |
| Magnetic Circuit Structure | Combined Type |
| Class | 0.5、1.0、3.0 |
| Measuring Range | 10%in-130%in |
| Packaging Details | Carton |
| Model Number | SCTK681A Series |
| Certification | RoHS |
| Place of Origin | China |
| Brand Name | Shinhom |
View Detail Information
Explore similar products
High Accuracy Split Core Current Sensor 100A Low Energy Consumption
RoHS Split Core Current Transformer Magnetic Circuit Structure High Precision
Low Voltage Magnetic Split Core CT Small Size Easy Mounting Wide Inner Window
Portable Split Core Current Transformer , Single Phase Current Transformer
Product Specification
| Supply Ability | 10000/MONTH | Current range | 5~630A |
| Customizable | Yes | Delivery Time | 4~8 Weeks |
| Frequency | 50Hz-2KHz | Payment Terms | T/T |
| Output | 0.333V(AC) or 0-500mA | Magnetic Circuit Structure | Combined Type |
| Class | 0.5、1.0、3.0 | Measuring Range | 10%in-130%in |
| Packaging Details | Carton | Model Number | SCTK681A Series |
| Certification | RoHS | Place of Origin | China |
| Brand Name | Shinhom | ||
| High Light | Split Core Current Transformer for motor monitoring ,Split Core CT wide frequency 50-2000Hz ,HVAC monitoring Split Core Current Transformer | ||
SCTK681A Series 5A-630A RoHS Split Core Current Transformers
The SCTK681A series split-core current transformer is designed for current measurement and monitoring in new or existing power distribution networks. Measuring range is 5A to 630A, with frequency range 50-2000Hz.The product uses a split-core structure that allows quick installation without disconnecting or removing cables or busbars. This significantly reduces installation cost and time.The secondary winding has a built-in precision parallel resistor, providing a safe low-voltage output of 0.333VAC or 0-500mA without the need for external sampling resistors.Ratio error: ≤±1.0%. Phase angle error: ≤±60 minutes. Dielectric strength: 2.5KV/1mA/1 minute. RoHS compliant.It is widely used in relay protection devices, motor current and power measurement, lighting, air compressors, HVAC, automation control systems, and power distribution line monitoring.
Features
Applications
Electrical Parameter
| Frequency | 50-2KHz |
| Rated Input | 5A-630A |
| Measuring range | 10%In-130%In |
| Rated Output | 0.333V(AC) or 0-500mA |
| Ratio | ≤± 1.0% |
| Phase angle | ≤ ±60min |
| Dielectric strength | 2.5KV/1mA/1min |
| Insulation Resistance | DC500V/100MΩmin |
Mechanical Parameter
| Case | PA /UL94-V0 |
| Bobbin | PBT |
| Core | Silicon steel |
| Internal structure | Epoxy |
| Construction | Tie |
| Operating Temp | -25℃~+75℃ |
| Operating Humidity | ≤85% |
| Output Connection | UL1015 20AWG Wire(twinsted wire) 2.5m |
Type selection
| P/N | Rated Input (A) | Output (mA/V) | Accuracy | Dimensions(mm/inch) | |||
|---|---|---|---|---|---|---|---|
| Ø | A | B | C | ||||
| SCTK681A-005 | 5-20A (5,8A,10,15,20) | 0-25mA 0.333V | 0.5,1.0,3.0 | 5.0 (0.20) | 31.5 (1.24) | 19.5 (0.77) | 21.0 (0.83) |
| SCTK681A-010 | 5-75A (5,10,20,50,75) | 0-50mA 0.333V | 0.5,1.0,3.0 | 10.0 (0.39) | 41.0 (1.61) | 24.0 (0.94) | 26.5 (1.04) |
| SCTK681A-016 | 5-150A (5,10,50,100,150) | 0-100mA 0.333V | 0.5,1.0,3.0 | 16.0 (0.63) | 45.5 (0.22) | 29.0 (1.14) | 31.5 (1.24) |
| SCTK681A-024 | 10-250A (10,50,100,200,250) | 0-200mA 0.333V | 0.5,1.0,3.0 | 24.5 (0.96) | 65.0 (2.56) | 45.0 (1.77) | 40.0 (1.57) |
| SCTK681A-035 | 10-630A (20,100,250,400,600) | 0-500mA 0.333V | 0.5,1.0,3.0 | 35.7 (1.41) | 81.5 (3.21) | 57.0 (2.24) | 51.0 (2.01) |
![]()
Notes:Product specifications can be customized
FAQ
Q: Does the split-core current transformer require power-off or cable removal during installation?
A: No. The SCTK681A series uses a split-core structure with a core that opens and closes. It can be installed without disconnecting or removing any cables or busbars. This feature makes it especially suitable for retrofit projects and applications where power cannot be turned off, significantly reducing installation costs and time.
Q: What is the function of the built-in precision resistor?
A: The secondary winding has a built-in precision parallel resistor. It converts the current signal directly into a safe low-voltage output (0.333VAC) or standard current signal (0-500mA). This eliminates the need for external sampling resistors. This design simplifies installation, improves safety, and saves component costs and installation space.
Q: What applications can the ≤±1.0% ratio error meet?
A: The ±1.0% ratio error meets the accuracy requirements of most industrial power monitoring, equipment protection, energy management, and automation control applications. For higher accuracy requirements such as energy metering, please consult us for models with higher accuracy classes.
Company Details
Business Type:
Manufacturer,Exporter,Seller,Other
Year Established:
2002
Total Annual:
5000000-6000000
Employee Number:
600-~800
Ecer Certification:
Verified Supplier
Shaanxi SHINHOM Enterprise Co.,Ltd is one large-sized key enterprise in producing magnetic components and supplying OEM`high quality magnetics components in China ,It has been approved for the certification ISO9001&QS9000.Shinhom has grown rapidly by supplying high quality magnetic ... Shaanxi SHINHOM Enterprise Co.,Ltd is one large-sized key enterprise in producing magnetic components and supplying OEM`high quality magnetics components in China ,It has been approved for the certification ISO9001&QS9000.Shinhom has grown rapidly by supplying high quality magnetic ...
Get in touch with us
Leave a Message, we will call you back quickly!