| Payment Terms | L/C, T/T | 
| Delivery Time | 35-40 Working Days | 
| Packaging Details | Export Package | 
| Color | Red | 
| Standard | NFPA 20 | 
| Function | Diesel Engine Control | 
| Brand | Tornatech | 
| Origin | UAE | 
| Application | Fire Fighting | 
| Brand Name | Tornatech | 
| Certification | UL,FM | 
| Place of Origin | Canada | 
| Model Number | GPD-24-120/220 | 
View Detail Information
Explore similar products
NFPA 70 STANDARD TORNATECH Diesel Engine Fire Pump Controller GFD 24-220
UL / FM Fire Pump Controller for Electric Motor Pump Fire Fighting Systems
Fire Pump Controller UL / FM standard for Jockey Pump Type XTJP series
UL FM Fire Pump Controller Worked for Jockey Pump for Fire Fighting Use
Product Specification
| Payment Terms | L/C, T/T | Delivery Time | 35-40 Working Days | 
| Packaging Details | Export Package | Color | Red | 
| Standard | NFPA 20 | Function | Diesel Engine Control | 
| Brand | Tornatech | Origin | UAE | 
| Application | Fire Fighting | Brand Name | Tornatech | 
| Certification | UL,FM | Place of Origin | Canada | 
| Model Number | GPD-24-120/220 | ||
| High Light | jockey pump controller ,diesel pump control panel ,UL Diesel Fire Pump Controller | ||
UL/ FM Tornatech Controller For Fire Fighting Systems
Diesel engine fire pump controllers are designed to automatically start a diesel engine driven fire pump upon
 detection of a pressure drop in the fire protection system. A diesel engine fire pump controller provides automatic &
 manual starting and stopping. An automatic start is controlled by a pressure transducer or by remote automatic
 devices as deluge valve. A manual start is controlled by remote manual button or by controller pushbutton. The
 automatic shutdown option provides a 30-minutes automatic stop after automatic start once all starting causes have
 returned to normal. The diesel engine fire pump controller includes two battery chargers to maintain the engine
 batteries continuously charged.
![]()
![]()
Types of Diesel Engine Fire Pump Controllers
![]()
METHODS OF STARTING
 AUTOMATIC START
 The controller will start automatically on low pressure detection by the pressure sensor when pressure drops below
 the cut-in threshold. The controller must be in automatic mode.
 MANUAL START
 The engine can be started by pressing the CRANK 1 or and/or CRANK 2 push button, regardless of the system
 pressure, when the Main Selector switch is in the HAND position. The Fuel Solenoid Valve will open as soon as a
 CRANK button is pressed and will remain in this state.
 REMOTE MANUAL START
 The engine can be started from a remote location by momentarily closing a contact of a manual push button.
 REMOTE AUTOMATIC START, DELUGE VALVE START
 The engine can be started from a remote location by momentarily opening a contact connected to an automatic
 device. The controller must be in automatic mode.
 SEQUENTIAL START
 In case of multiple pump application, it may be necessary to delay the starting of each motor in case of water
 pressure drop to prevent simultaneous starting of all motors.
FLOW START, HIGH ZONE START
 The controller can be started by opening/closing a contact on the FLOW/ZONE START/STOP input.
 WEEKLY START
 The engine can be started (and stopped) automatically at the preprogrammed time.
 TEST START
 The motor can be started automatically for a preprogrammed time by pressing the run test button.
METHODS OF STOPPING
 MANUAL STOP
 Manual stop is done by pressing the STOP push button. Note that pressing the stop push button will stop the
 engine only if all starting causes have disappeared.
 AUTOMATIC STOP
 The automatic stop is possible only after an automatic start and this function must be activated. When this function
 is enabled, the motor is automatically stopped 30 minutes after the restoration of the pressure (above the cut-out
 threshold) given that no other run cause is present.
 FLOW STOP, HIGH ZONE STOP
 If the controller has been started by the FLOW/ZONE START/STOP input and that the signal has returned to
 normal, the motor will be stopped given that no other run cause is present.
 EMERGENCY STOP
 The emergency stop is always possible in any running condition and is done by positioning the main selector switch
 to the OFF position.
![]()
Company Details
Business Type:
Manufacturer,Importer,Exporter,Trading Company,Seller 
Year Established:
2012 
Total Annual:
5000000-30000000
Employee Number:
100~200 
Ecer Certification:
Verified Supplier 
Wuhan Spico Machinery & Electronics Co., Ltd.(Hereinafter referred to as SPICO) is the Wuhan office of CNP NM Fire-fighting System Co.,Ltd (Hereinafter referred to as NM Fire). SPICO mainly resp- onsible for product promotion,export declaration and foreign exchange co... Wuhan Spico Machinery & Electronics Co., Ltd.(Hereinafter referred to as SPICO) is the Wuhan office of CNP NM Fire-fighting System Co.,Ltd (Hereinafter referred to as NM Fire). SPICO mainly resp- onsible for product promotion,export declaration and foreign exchange co...
Get in touch with us
Leave a Message, we will call you back quickly!