SHELL | SA387 GRADE22 CLASS2 |
CHANNEL FLANGE | SA336 F22 CLASS3 |
TUBES | SA213 T22 |
TUBESHEET | SA336 F22 CLASS3 |
BAFFLES | SA387 GRADE22 CLASS2 |
SUPPORTS | SA516 GRADE 70 |
Brand Name | YUHONG |
Model Number | BEP Type |
Certification | ASME, ABS, DNV-GL , BV, LR , KR, CCS, PED, TUV, ISO9001, AD2000 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Assembly Design Shell And Tube Heat Exchanger ASME TEMA
ASME U Stamp Heat Exchanger API 660 In Petrochemical And Oil Refinery
Shell And Tube Heat Exchanger API 660 ASME U Stamp For Petrochemical Industry
ASTM A312 TP316L Seamless Tubes With ASTM A516 Gr 70 Carbon Steel Shell For Heat
Product Specification
Payment Terms | T/T, L/C at sight | Supply Ability | 60 SETS/MONTH |
Delivery Time | 45---150 DAYS | Packaging Details | Requirements/ Ply-wooden Case/ Iron Case/ Bundle with plastic Cap |
SHELL | SA387 GRADE22 CLASS2 | CHANNEL FLANGE | SA336 F22 CLASS3 |
TUBES | SA213 T22 | TUBESHEET | SA336 F22 CLASS3 |
BAFFLES | SA387 GRADE22 CLASS2 | SUPPORTS | SA516 GRADE 70 |
Brand Name | YUHONG | Model Number | BEP Type |
Certification | ASME, ABS, DNV-GL , BV, LR , KR, CCS, PED, TUV, ISO9001, AD2000 | Place of Origin | CHINA |
T22 Gas-Gas Heat Exchangers BEP Type ASME VIII Divison 2 Class 2
The T22 Gas-Gas Heat Exchanger (BEP Type), designed per ASME VIII Division 2 Class 2, efficiently transfers heat between gas streams in high-temperature applications. Made from T22 alloy steel, it offers excellent thermal and mechanical performance, ideal for power plants, refineries, and chemical processing. Its BEP design ensures easy maintenance and durability.
Heat Exchanger Types
Type | Description | Applications |
---|---|---|
BEP Type (Bonnet End Plate) | Features a removable bonnet that allows access to the tube bundle for cleaning and maintenance. | Gas-to-gas heat transfer in high-temperature applications like power plants and refineries. |
Floating Head Type | Includes a floating head that accommodates thermal expansion of the tube bundle. | Suitable for cases with significant thermal expansion, such as steam generators. |
Fixed Tube Sheet Type | Tube sheets are welded to both ends of the shell, providing a simple and cost-effective design. | Common in low to moderate temperature and pressure applications. |
U-Tube Heat Exchanger | U-shaped tubes allow for expansion of the tube side without requiring other expansion allowances. | Ideal for heating or cooling fluids with large temperature differences. |
Kettle Reboiler | A shell-and-tube heat exchanger designed to vaporize a fluid at the tube side using a shell-side fluid. | Widely used in distillation and evaporation processes. |
Double Pipe Heat Exchanger | Consists of a tube inside a larger pipe, allowing two fluids to exchange heat in a counterflow manner. | Used in smaller-scale applications or when space is limited. |
Common Heat Exchanger Materials
Spec. No. | Type/Grade |
SA-36 | SA-36 |
SA-53 | EA, EB, E/B, S/A, S/B |
SA-105 | SA-105 |
SA-106 | A, B, C |
SA-135 | A, B |
SA-178 | A, C |
SA-179 | SA-179 |
SA-181 | SA-181 |
SA-182 | FR, F1, F2, F3V, F3VCb, F5, F5a, F9, F11 Cl. 1 & 2, F12 Cl. 1 & 2, F21, F22 Cl. 1 & 3, F22V,F91 |
SA-192 | SA-192 |
SA-193 | B5, B7, B7M, B16 |
SA-203 | A, B, D, E, F |
SA-204 | A, B, C |
SA-209 | T1, T1a, T1b |
SA-210 | A-1.C |
SA-213 | T2, T5, T5b, T5c, T9, T11, T12, T17.. T21, T22, T91 |
SA-214 | SA-214 |
SA-216 | WCA, WCB, WCC |
SA-217 | C12, C5, WC1, WC4, WC5, WC6, WC9 |
SA-225 | C |
SA-234 | WPE, WPC, WPR, WP1, WP5, WP9. WP11 C1. 1.WP12 CI. 1.WP22 CL.1 |
SA-250 | T1, T1a, T1b |
SA-266 | 1, 2, 3, 4 |
SA-283 | C, D |
SA-285 | A, B, C |
SA-299 | A, B |
SA-302 | A, B, C, D |
SA-307 | A, B |
SA-320 | L7, L7A, L7M, L43 |
SA-325 | 1 |
SA-333 | 1, 3, 4, 6, 7, 9 |
SA-334 | 1, 3, 6, 7, 9 |
SA-355 | P1, P2, P5, P5b, P5c, P9, P11, P12, P15,P21.P22. P91 |
SA-336 | F1, F3V, F3VCb, F5, F5A, F9,F11 C1. 2& 3, F12,F21 CL.1 &3,F22 CL.1 &3.F22V,F91 |
SA-350 | LF1, LF2.LF3 LF5.LF9 |
SA-352 | LCB, LC1. LC2.LC3 |
SA-354 | BC, BD |
SA-369 | FP1, FP2, FP5, FP9, FP11, FP12, FP21. FP22 |
SA-372 | A; B;C;D;E CL.55,65,&70:F CL.55, 65,&70; G CL.55.65,&70: H CL. 55,65,& 70;j CL. 55,65,70,& 110:L: M CL.85 &100 |
SA-387 | 2, 11, 12, M, 21, 22, 91 |
SA-414 | A, B, C, D, E, F, G |
SA-420 | WPL 3, WPL 6, WPL 9 |
SA-423 | 1, 2 |
SA-437 | B4B, B4C |
SA-449 | SA-449 |
SA-455 | SA-455 |
SA-487 | 1 Cl. A & B, 2 Cl. A & B, 4 Cl. A, 8 Cl. A |
SA-508 | 1, 1A, 2 Cl 1, 2 Cl. 2,3 Cl. 1, 3 CL. 2, 3V, 3VCb. 4N CL. 3, 22 CL. 3 |
SA-515 | 60, 65, 70 |
SA-516 | 55, 60, 65, 70 |
SA-524 | I,II |
SA-533 | A Cl.1&2,B Cl.1 & 2, C CL.1 & 2, D Cl.2, E Cl. 1 & 2 |
SA-537 | Cl. 1, 2, & 3 |
SA-540 | B21, B22, B23, B24, B24V |
SA-541 | 1, 1A, 2 Cl. 1, 2 Cl. 2, 3 Cl. 1, 3 C1. 2, 3V, 3VCb, 22 Cl.3, 22V |
SA-542 | B Cl. 4, C Cl. 4a, D Cl. 4a, E Cl. 4a |
SA-556 | A2, B2, C2 |
SA-562 | ... |
SA-574 | 4037,4042,4140,4340,5137M 51B37M |
SA-587 | SA-587 |
SA-612 | SA-612 |
SA-662 | A, B, C |
SA-675 | 45, 50, 55, 60, 65, 70 |
SA-727 | SA-727 |
SA-737 | B, C |
SA-738 | A, B, C |
SA-739 | B11, B22 |
SA-765 | l, ll, lll, IV |
SA-832 | 21V,22V,23V |
SA-836 | SA-836 |
SA-841 | A Cl. 1, B CI. 2 |
SA-1008 | CS-A.CS-B |
SA/AS 1548 | PT430,PT460,PT490 |
SA/CSA-G40.21 | 38W, 44W, 50W |
SA/EN 10028-2 | P235GH,P265GH,P295GH, P355GH,13CrMo4-5, 10CrMo9-10 |
SA/EN 10028-3 | P275NH |
SA/EN 10216-2 | P235GH,P265GH,16Mo3, 13CrMo4-5,10CrMo9-10 |
SA/EN 10222-2 | P280GH, P305GH,13CrMo4-5, 11CrMo9-10 |
SA/GB 713 | Q345R |
SA/IS 2062 | E250A,E250BR,E250B0,E250C |
Applications of Gas-Gas Heat Exchangers
Industry | Specific Applications |
---|---|
Power Generation | - Gas turbine exhaust heat recovery. |
- Waste heat boilers and air preheaters in thermal plants. | |
Petrochemical | - Preheating combustion air in refineries. |
- Cooling tail gases in sulfur recovery units (SRU). | |
Chemical Processing | - Managing heat in catalytic cracking and reforming processes. |
- Tail gas heating and cooling in fertilizer plants. | |
Metallurgy | - Heat recovery from flue gases in steel and aluminum production. |
- Air preheaters in smelters and foundries. | |
Environmental Systems | - Reducing exhaust gas temperatures for scrubbers and filtration systems. |
- Heat recovery in waste incineration plants. | |
Oil & Gas | - Cooling hydrogen-rich gases in hydrocrackers. |
- Heating process gases in natural gas processing facilities. |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2007
Total Annual:
50M-70M
Employee Number:
50~850
Ecer Certification:
Verified Supplier
YUHONG HOLDING GROUP is one of the largest Procurement, Engineering & Contracting Group companies in China. Our group branch company and factory have been already approved by : ABS, LR, DNV, GL, BV, CCS, KR, PED 97/23/EC, AD2000-WO, GOST9941-81, CCS, TS, CNNC, ISO9... YUHONG HOLDING GROUP is one of the largest Procurement, Engineering & Contracting Group companies in China. Our group branch company and factory have been already approved by : ABS, LR, DNV, GL, BV, CCS, KR, PED 97/23/EC, AD2000-WO, GOST9941-81, CCS, TS, CNNC, ISO9...
Get in touch with us
Leave a Message, we will call you back quickly!