Description 8 analog input/output series,IOLINKslave station,
product description IO-LINK slave module 8×AlO port IP67 protection class
I/O connection mode M12,5pin hole holder, A code
Connection type 1x M12 A-code; 5- Core hole holder
Communication protocol IOLINK
Communication rate 38.4 kbit/s(COM2)
Minimum cycle time |55 ms
Communication port tightening torque M12;0.5Nm
System supply voltage US 18…30 VDC(type.24VDC)
Power port tightening torque M12:0.5Nm
No load current consumption ≤80mA
Number of inputs and outputs 8 channel current or voltage
Input and output port locations J1…J8
Current input and output range 0~20 mA,4~20 mA
Voltage input and output range 0~+5 VDC;0~+10 VDC;+5~+10 VDC
Diagnose Contains self-diagnosis
Sensor power supply 24VDC
Ripple wave <1%
Voltage input and output error <+0.3% full scale
Current input and output errors <±0.3% full scale
Resolution ratio 16 bit
Measurement display and output format 16 bit unsigned integer
Factory settings 0~+10 VDC input
Shell material PA6+GF
Shell color black
level of protection IP67, epoxy full potting
Boundary dimension 155mm x53mm x28.7mm
Weight 217g
Operating temperature -25°C...70°C
Storage/transport temperature 40°C...85°C
Operation humidity 5%...95%
Store/transport humidity 5%...95%
Operating atmospheric pressure 80KPa...106KPa
Store/transport atmospheric pressure 80KPa...106KPa
I/O port tightening torque M12:0.5Nm
Application environment Comply with IEC60068-2
Impact test Comply with IEC60068-27
Free drop test Comply with IEC60068-32
Electromagnetic compatibility (EMC) Comply with IEC61000-4-2,-3,-4
Authentication CE,RoHS
Mounting hole specification ∅4.3mm x 4
Brand Name SUPERISYS
Model Number 8 Analog input and output series
Certification ISO\FCC\ROSH
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 1000 per day
Delivery Time 1-2 work days Stock In Stock
Description 8 analog input/output series,IOLINKslave station, product description IO-LINK slave module 8×AlO port IP67 protection class
I/O connection mode M12,5pin hole holder, A code Connection type 1x M12 A-code; 5- Core hole holder
Communication protocol IOLINK Communication rate 38.4 kbit/s(COM2)
Minimum cycle time |55 ms Communication port tightening torque M12;0.5Nm
System supply voltage US 18…30 VDC(type.24VDC) Power port tightening torque M12:0.5Nm
No load current consumption ≤80mA Number of inputs and outputs 8 channel current or voltage
Input and output port locations J1…J8 Current input and output range 0~20 mA,4~20 mA
Voltage input and output range 0~+5 VDC;0~+10 VDC;+5~+10 VDC Diagnose Contains self-diagnosis
Sensor power supply 24VDC Ripple wave <1%
Voltage input and output error <+0.3% full scale Current input and output errors <±0.3% full scale
Resolution ratio 16 bit Measurement display and output format 16 bit unsigned integer
Factory settings 0~+10 VDC input Shell material PA6+GF
Shell color black level of protection IP67, epoxy full potting
Boundary dimension 155mm x53mm x28.7mm Weight 217g
Operating temperature -25°C...70°C Storage/transport temperature 40°C...85°C
Operation humidity 5%...95% Store/transport humidity 5%...95%
Operating atmospheric pressure 80KPa...106KPa Store/transport atmospheric pressure 80KPa...106KPa
I/O port tightening torque M12:0.5Nm Application environment Comply with IEC60068-2
Impact test Comply with IEC60068-27 Free drop test Comply with IEC60068-32
Electromagnetic compatibility (EMC) Comply with IEC61000-4-2,-3,-4 Authentication CE,RoHS
Mounting hole specification ∅4.3mm x 4 Brand Name SUPERISYS
Model Number 8 Analog input and output series Certification ISO\FCC\ROSH
Place of Origin CHINA
High Light IP67 IO LINKIO LINK Slave ModuleIOLINK Protocol

IACM-AIO8VI-IOL,IOLINK Slave Station,8 Analog Input/Output Series

 

Product characteristics

 

Operating voltage: 10-30VDC

 

Output function: NPN/PNP, NO/NC Optional

 

With polarity, overload, short circuit protection

 

Protection level: IP67

 

Direct outlet type, connector type

 

Operating temperature -25°C-+70%C

 

The use of optimized traditional technology and advanced packaging technology to ensure long-term stability in harsh Environments

 

IO-LINK Model Product Description I/O Connection Mode
Class A IACM-AIO8VI-IOL IO-LINK Slave Module 8×AlO port IP67 Protection class M12,5Pin hole holder,
A code
Communication and power parameters
Connection type 1x M12 A-code; 5- Core hole holder
Communication protocol IOLINK
Communication rate 38.4 Kbit/s(COM2)
Minimum cycle time |55 ms
Communication port tightening torque M12;0.5Nm
System supply voltage US 18…30 VDC(type.24VDC)
Power port tightening torque M12:0.5Nm
No load current consumption ≤80mA
Analog input and output parameters
Number of inputs and outputs 8 Channel current or voltage
Input and output port locations J1…J8
Current input and output range 0~20 mA,4~20 mA
Voltage input and output range 0~+5 VDC;0~+10 VDC;+5~+10 VDC
Diagnose Contains self-diagnosis
Sensor power supply 24VDC
Ripple wave <1%
Voltage input and output error <+0.3% Full scale
Current input and output errors <±0.3% Full scale
Resolution ratio 16 Bit
Measurement display and output format 16 Bit unsigned integer
Factory settings 0~+10 VDC input
Module indicator light
IOLINK protocol
PWR Green: the module power supply is normal
  Out: The module does not have power supply
Al Extinguished (LEDA,LEDB) : The port is closed
(J1.….J8) Green (LEDA) : channel signal is normal, input/output signal is within valid range
  Red (LEDA) : input/output signals are not in valid range
  Red (LEDA,LEDB) : 1 and 3 pin short circuit or port break
IO-LINK Green: communication is not connected
Green flash: communication is normal
Green flash: communication is normal
I/O port pin definition
Port Definition of stitch Address distribution
M12
A-Code Mother end
 
 
 
 
 
 
Underlying parameter
Dimension Figure Shell material PA6+GF
Shell color Black
level of protection IP67, epoxy full potting
Boundary dimension 155mm x53mm x28.7mm
Weight 217g
Operating temperature -25°C...70°C
Storage/transport temperature 40°C...85°C
Operation humidity 5%...95%
Store/transport humidity 5%...95%
Operating atmospheric pressure 80KPa...106KPa
Store/transport atmospheric pressure 80KPa...106KPa
I/O Port tightening torque M12:0.5Nm
Application environment In accordance with EN-61131
Application environment Comply with IEC60068-2
Impact test Comply with IEC60068-27
Free drop test Comply with IEC60068-32
Electromagnetic compatibility (EMC) Comply with IEC61000-4-2,-3,-4
Authentication CE,RoHS
Mounting hole Specification ∅4.3mm x 4

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2017

  • Total Annual:

    4181579.9475 -6272550.2998

  • Employee Number:

    50~80

  • Ecer Certification:

    Active Member

Founded in 2017, Superisys is a specializing in industrial identification, communication, sensing, and data. In 2020, it acquired the renowned Canadian automatic sensing and big data company, Superisys, and established the Toronto R&D center to conduct business in industrial sensing, industri... Founded in 2017, Superisys is a specializing in industrial identification, communication, sensing, and data. In 2020, it acquired the renowned Canadian automatic sensing and big data company, Superisys, and established the Toronto R&D center to conduct business in industrial sensing, industri...

+ Read More

Get in touch with us

  • Reach Us
  • Superisys (Wuhan) Intelligent Technology Co., Ltd
  • Superisys (Wuhan) China: 12-1B, Liandong U Valley, Yangluo Development Zone, Wuhan City, China.
  • https://www.superisys.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement