China factories

Chat Now Send Email
China factory - Britec Electric Co., Ltd.

Britec Electric Co., Ltd.

  • China ,Zhejiang
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China BR-25GRS SPD Surge Protective Device 3+1 Type 1 Surge Protector
China BR-25GRS SPD Surge Protective Device 3+1 Type 1 Surge Protector

  1. China BR-25GRS SPD Surge Protective Device 3+1 Type 1 Surge Protector

BR-25GRS SPD Surge Protective Device 3+1 Type 1 Surge Protector

  1. MOQ: 100 Piece/Pieces
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, T/T, Western Union
Supply Ability 500000 Piece/Pieces Month
Delivery Time Shipped in 25 days after payment
Packaging Details EXPORT PACKING
Rated Voltage 150V/275V/320V
Model Numbers BR-25GRS 3+1
OEM YES
Weight (g) 500
Item Name Surge protective
Place of Origin Zhejiang, China (Mainland)
Standard IEC61643-1
Color White, Grey
Class Type 1
Brand Name BRITEC
Model Number BR-25GRS 3+1
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, T/T, Western Union Supply Ability 500000 Piece/Pieces Month
Delivery Time Shipped in 25 days after payment Packaging Details EXPORT PACKING
Rated Voltage 150V/275V/320V Model Numbers BR-25GRS 3+1
OEM YES Weight (g) 500
Item Name Surge protective Place of Origin Zhejiang, China (Mainland)
Standard IEC61643-1 Color White, Grey
Class Type 1 Brand Name BRITEC
Model Number BR-25GRS 3+1 Place of Origin China
High Light BR-25GRS SPD Surge Protective DeviceType1 Surge Diverter Module3+1 SPD Surge Protective Device

BR-25GRS 3+1 Type 1 Surge Diverter Module SPD Features:

 

Type: T1+T2 Surge protector

Working voltage: 240V/400V.
Response time: ≤100ns
Normal discharge current (8/20us) In: 25kA / 100kA.
Maximum discharge current: 50kA/160kA
Labeled connections.
• Maximum operating voltage: 150V/275V/320V
Composite type: 3P+NPE.
Temperature range: -40℃—80℃
Installation: standard rail 35mm.
Designed to protect low-voltage electrical installations from electrical surges caused by switching action, lightning strikes and electromagnetic pulses.
According to IEC61643-1.

 

BR-25GRS 3+1 Type 1 Surge Diverter Module SPD Technology characteristic:

 

  BR-25GRS 3+1
Nominal voltage                                                                  Un 240V / 400V AC
Max. continuous operating a.c. voltage (L-N / N-PE)         Uc 275V/255V
Lightning impulse current (10/350us) (L-N / N-PE)          Iimp 25kA / 100kA
Nominal discharge current (8/20us) (L-N / N-PE)                In 25kA / 100kA
Maximum discharge current (8/20us) (L-N / N-PE)         Imax 50kA / 160kA
Voltage protection level (L-N / N-PE)                                  Up ≤1.8kV
Response time                                                                     tA ≤100ns
Max. backup fuse 250A gG
Operating temperature range                                              Tu -40℃—80℃
Cross-section area (Min.) 4mm2
Cross-section area (Max.) 35mm2
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Test standards             IEC 61643-11, EN 61643-11            


Dimension:

BR-25GRS 3+1 Type 1 Surge Diverter Module SPD Application:
   

It is installed in the power grid inlet of the 240V/400V low-voltage power supply system or in the general distribution cabinet.

For installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage.
Can be used to protect three-phase power system.
 
IEC standard refer to the International Electrotechnical Commission standards, which are globally recognized and accepted guidelines for electrical and electronic devices. Spd stands for Surge Protective Device, which is a device used to protect electrical equipment from voltage surges or transient voltage events. The IEC has developed several standards for SPDs, which outline the requirements and testing procedures for these devices.
SPD stands for Surge Protective Device, which is used to protect electrical systems and equipment from power surges and transient voltage spikes.
 
What is the difference between TVSS and SPD?
 
There is no difference. The change in terminology from TVSS (transient voltage surge suppression) to SPD (surge protective device) was mandated by the 3rd Edition of the UL 1449 standard.
 
Certificate:
 
 
Production line:
 
 
Laboratory equipment:
 
 
Shipping:
 
 
FAQ:
 
Q1: What is the MOQ?
A1: 100pcs.

Q2: Is OEM/ODM available?
A2: Yes, it is! Our products can be Customized. We have design and engineer teams, we can customize products according to customers’ drawing or requirements.

Q3: Can we put/show our own Logo on your products?
A3: Yes.

Q4: What is the Terms of Payment?
A4: T/T, PAYPAL etc.

Q5: How is the delivery time?
A5: It depends your order quantity and it normally takes 25 days.
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2003

  • Total Annual:

    1-1000

  • Employee Number:

    1~200

  • Ecer Certification:

    Verified Supplier

Britec Electric specialized in research and development of lightening protection devices. The new series of surge protection device Type1,Type2 and Type3,BR PV and SPDs for Date offer the market with a new choice of high quality surge arresters.   Established in 2003, is a professio... Britec Electric specialized in research and development of lightening protection devices. The new series of surge protection device Type1,Type2 and Type3,BR PV and SPDs for Date offer the market with a new choice of high quality surge arresters.   Established in 2003, is a professio...

+ Read More

Get in touch with us

  • Reach Us
  • Britec Electric Co., Ltd.
  • Block 1 , BoTongHuiGu industrial Park, Yueqing, Zhejiang ,China 325600
  • https://www.surge-protectiondevice.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement