China factories

Chat Now Send Email
China factory - Hangzhou Nanyin Trading Co., Ltd.

Hangzhou Nanyin Trading Co., Ltd.

  • China,Hangzhou
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid
China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid

  1. China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid
  2. China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid
  3. China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid
  4. China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid
  5. China Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid

Huawei CloudEngine Switch S5731-H24HB4XZ with 20 Hybrid GE SFP Ports 4 Hybrid

  1. MOQ: 1
  2. Price: $1225
  3. Get Latest Price
Payment Terms T/T,Western Union,MoneyGram
Supply Ability 250pcs
Delivery Time 3-5 days
Description S5731-H24HB4XZ (20*Hybrid GE SFP ports, 4*Hybrid 10GE SFP+ ports, 4*10GE SFP+ ports, 1*expansion slot, PoE++, without power module)
Condition Original New; In stock
Brand Name Huawei
Model Number S5731-H24HB4XZ

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union,MoneyGram Supply Ability 250pcs
Delivery Time 3-5 days Description S5731-H24HB4XZ (20*Hybrid GE SFP ports, 4*Hybrid 10GE SFP+ ports, 4*10GE SFP+ ports, 1*expansion slot, PoE++, without power module)
Condition Original New; In stock Brand Name Huawei
Model Number S5731-H24HB4XZ
High Light 20 Hybrid GE SFP Ports Huawei Network Switch ,4 Hybrid 10GE SFP+ Ports CloudEngine Switch ,4 10GE SFP+ Ports S5731-H24HB4XZ

Huawei CloudEngine Switch S5731-H24HB4XZ (02354QXD 02354QXD-001)


The CloudEngine S5731-H series switches are the next-generation intelligent gigabit fixed switches developed by Huawei. The CloudEngine S5731-H builds on Huawei's unified Versatile Routing Platform (VRP) and boasts various IDN features. For example, the integrated wireless AC capabilities can manage up to 1,024 wireless APs; the free mobility feature ensures consistent user experience; the VXLAN functionality implements network virtualization; and built-in security probes support abnormal traffic detection, threat analysis even in encrypted traffic, and network-wide threat deception. With these merits, the CloudEngine S5731-H can function as core switches for small-sized campus networks and branches of medium- and large-sized campus networks, and also work as access switches for Metropolitan Area Network.



Quick Specification

 

Table 1 shows the Quick Specification.



Model

S5731-H24HB4XZ

Part Number

02354QXD, 02354QXD-001

Description

S5731-H24HB4XZ (20*Hybrid GE SFP ports, 4*Hybrid 10GE SFP+ ports, 4*10GE SFP+ ports, 1*expansion slot, PoE++, without power module)

Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.4 in. x 17.64 in.)

Weight with packaging [kg(lb)]

7.5 kg (16.53 lb)

Typical power consumption [W]

87 W

Maximum power consumption [W]

Without PoE: 127 W (without cards)

Full PoE load: 1927 W (PoE: 1768 W, without cards)

Memory

2 GB

Flash memory

1 GB in total. To view the available flash memory size, run the display version command.

PoE

Supported




Figure 1 shows the appearance of S5731-H24HB4XZ.

front-s5731-h24hb4xz-datasheet


Product Details

 

Figure 2 shows the structure of S5731-H24HB4XZ.

structure-s5731-h24hb4xz-datasheet

Note:


(1)

Twenty 100/1000BASE-X hybrid optical-electrical ports (supporting PoE++)

(8)

Ground screw

(2)

Four 10GE SFP+ hybrid optical-electrical ports (supporting PoE++)

(9)

Rear card slot

(3)

Four 10GE SFP+ optical ports

(10)

Fan module slot 1

(4)

One ETH management port

(11)

Fan module slot 2

(5)

One console port

(12)

Power module slot 1

(6)

One USB port

(13)

Power module slot 2

(7)

One PNP button





Figure 3 shows the indicators on the S5731-H24HB4XZ.

indicators-s5731-h24hb4xz-datasheet


Table 2 shows the description of indicators on the S5731-H24HB4XZ.

No.

Indicator

Name

Color

Status

Description

1

PWR1

Power module indicator

-

Off

No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 1 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 1:

● A power module is available in this slot but it is not connected to a power source.

● The power module in this slot has failed.

2

PWR2

Power module indicator

-

Off

No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally.

Green

Steady on

A power module is installed in power module slot 2 and is working normally.

Yellow

Steady on

The switch has two power modules installed. Any of the following situations occurs in power module slot 2:

● A power module is available in this slot but it is not connected to a power source.

● The power module in this slot has failed.

3

SYS

System status indicator

-

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

4

MST

Stack indicator

-

Off

● If you are not changing the indicator mode (default): The switch is a standby or slave switch in a stack or the stacking function is not enabled on the switch.

● If you are changing the indicator mode: The stack mode is not selected.

Green

Steady on

The stack mode is selected. The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch.

Green

Blinking

● If you are not changing the indicator mode (default): The switch is the master switch in a stack or a standalone switch with the stacking function enabled.

● If you are changing the indicator mode: The stack mode is selected. The switch is the master switch in a stack or a standalone switch, and the service port indicators show the stack ID of the master switch. After 45 seconds, the service port indicators automatically restore to the status mode.

5

SPEED

Speed indicator

-

Off

The speed mode is not selected.

Green

Steady on

The speed mode is selected, and service port indicators show the speed of each port.

6

PoE

PoE indicator

-

Off

The PoE mode is not selected.

Green

Steady on

The PoE mode is selected, and service port indicators show the PoE status of each port.

7

MODE

Mode switch button

-

-

● When you press this button once, the service port indicators change to the stack mode and show the stack ID of the local switch.

● When you press this button a second time, the service port indicators change to the speed mode and show the speed of each service port.

● When you press this button a third time, the service port indicators change to the PoE mode and show the PoE status of each service port.

● When you press this button a fourth time, the service port indicators restore to the default mode and show the connection status and link activity of each service port.

If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the SPEED and PoE indicators are off.

NOTE:

Hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:

● If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:

● If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.

● If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore the default status.

● If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.

8

-

Hybrid optical-electrical port indicator

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Meanings of service port indicators vary in different modes.

10GE optical port indicator

Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

9

ID

ID indicator

-

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

10

L/A

ETH port indicator

-

Off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The ETH port is sending or receiving data.

11

USB

USB-based deployment indicator

-

Off

● No USB flash drive is connected to the switch.

● The USB port is damaged.

● The indicator is damaged.

● The USB flash drive does not have any configuration file and cannot be used for deployment.

● The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Green

Blinking

The system is reading data from a USB flash drive.

Yellow

Steady on

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.


Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler

  • Year Established:

    2016

  • Total Annual:

    $2000000-US$5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

HI-NETWORK Company (Hangzhou Nanyin Trade Co.,LTD) was based on 2016 Year. Nearly 10 years experience in Networking Brands Field, Included: De ll, HPE, Oracle, Supermicro, Cisco Hua-Wei ZTE etc.  Customer are over 102 countries till now with good support. Welcome contact us for more enquiry! HI-NETWORK Company (Hangzhou Nanyin Trade Co.,LTD) was based on 2016 Year. Nearly 10 years experience in Networking Brands Field, Included: De ll, HPE, Oracle, Supermicro, Cisco Hua-Wei ZTE etc.  Customer are over 102 countries till now with good support. Welcome contact us for more enquiry!

+ Read More

Get in touch with us

  • Reach Us
  • Hangzhou Nanyin Trading Co., Ltd.
  • Room 405 Floor 4th. Meidu Square. Hangzhou City. China
  • https://www.switches-network.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement