| Supply Ability | Stock |
| Output Waveform | Pure Sinewave |
| Delivery Time | 3-5 Days |
| Output Voltage | 3 x 380VAC/400VAC /415VAC(3Ph + N) |
| Payment Terms | T/T,Western Union,L/C |
| Input Voltage | 3 x 380VAC/400VAC (3Ph + N) |
| Transfer Time | Zero |
| Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) |
| Capacity | 120KVA/96KW |
| Packaging Details | Pallet |
| Model Number | W-120KL |
| Certification | CE |
| Brand Name | BLAZING POWER |
| Place of Origin | China |
View Detail Information
Explore similar products
120KVA 96KW Uninterruptible Power Supply For Factories / Hospitals
60KVA Dual Input Low Frequency UPS with Pure Sinewave Output for Medical Devices
120KVA Low Frequency Online UPS with Pure Sine Wave Output and Zero Transfer
Pure Sinewave UPS Uninterruptible Power Supply 60KVA 48KW for Medical Devices
Product Specification
| Supply Ability | Stock | Output Waveform | Pure Sinewave |
| Delivery Time | 3-5 Days | Output Voltage | 3 x 380VAC/400VAC /415VAC(3Ph + N) |
| Payment Terms | T/T,Western Union,L/C | Input Voltage | 3 x 380VAC/400VAC (3Ph + N) |
| Transfer Time | Zero | Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) |
| Capacity | 120KVA/96KW | Packaging Details | Pallet |
| Model Number | W-120KL | Certification | CE |
| Brand Name | BLAZING POWER | Place of Origin | China |
| High Light | 120KVA Uninterruptible Power Supply ,Pure Sinewave Output UPS ,Zero Transfer Time Low Frequency UPS | ||
The low-frequency transformer-based design provides strong electrical isolation and excellent overload and transient-load handling. This makes the UPS suitable for critical IT environments where power reliability is essential.
Key advantages include:
For a server room or small-to-medium data center, the 120KVA UPS system can serve as the centralized backup power source for critical IT loads. When utility power fails, the UPS immediately supplies power from the battery system, allowing servers and network equipment to continue operating without an interruption that would normally cause a shutdown.
The backup time can be configured according to the required load and battery capacity. External battery cabinets can also be used when longer runtime is required.
A 120KVA UPS for a server room is suitable for applications requiring reliable power protection and centralized backup. It can protect critical equipment such as servers, storage, network switches, firewalls, communication systems, and monitoring equipment.
For higher availability requirements, the UPS system can be integrated with a maintenance bypass, generator, intelligent monitoring system, and appropriate power distribution equipment.
| Product Name | 120KVA Low-Frequency Online UPS |
| Rated Capacity | 120KVA / 96KW |
| UPS Type | Online Double-Conversion UPS |
| Design | Low-Frequency Transformer-Based |
| Input Voltage | 380VAC / 400VAC / 415VAC, 3-Phase 4-Wire + PE |
| Input Voltage Range | ±25% (Customizable) |
| Input Frequency | 50Hz / 60Hz |
| Input Frequency Range | 40–70Hz |
| Input Power Factor | ≥0.8 / ≥0.9 (Depending on Configuration) |
| Input THDi | ≤5% |
| Output Voltage | 380VAC / 400VAC / 415VAC, 3-Phase 4-Wire + PE |
| Output Voltage Regulation | ±1% |
| Output Frequency | 50Hz / 60Hz |
| Output Frequency Accuracy | ±0.1Hz |
| Output Power Factor | 0.8 |
| Output Waveform | Pure Sine Wave |
| Output THDv | ≤3% (Linear Load) |
| Overload Capability | 105–110%: Continuous; 125%: 10 min; 150%: 1 min (Typical) |
| Crest Factor | 3:1 |
| Transfer Time | 0ms (Online Double-Conversion Mode) |
| Battery Type | Maintenance-Free VRLA Battery |
| Battery Voltage | 384VDC (32 * 12V, Adjustable by Design) |
| Battery Capacity | According to Required Backup Time |
| Charging Method | Constant Current / Constant Voltage Intelligent Charging |
| Bypass | Static Bypass + Maintenance Bypass |
| Efficiency | ≥90% |
| Display | LCD / LED Display |
| Communication | RS232 / RS485 / USB / SNMP (Optional) |
| Protection | Input Over/Under Voltage, Output Over Voltage, Short Circuit, Overload, Over Temperature, Low Battery, etc. |
| Cooling | Forced Air Cooling |
| Operating Temperature | 25–40℃ |
| Relative Humidity | 0–95%, Non-Condensing |
| Altitude | ≤1000m (Derating Required Above 1000m) |
| Noise Level | ≤65dB at 1m (Typical) |
| Protection Degree | IP20 |
| Installation | Floor-Standing |
| Cabinet Color | Black / Gray (Customizable) |
| Insulation Class | Class H or According to Transformer Design |
| Dimensions | 975*554*1286mm |
| Net Weight | 597kg |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
2001
Total Annual:
10000000-20000000
Employee Number:
100~500
Ecer Certification:
Verified Supplier
.gtr-container-f7h2k9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-f7h2k9 .gtr-main-title { font-size: 18px; font-weight: bo... .gtr-container-f7h2k9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-f7h2k9 .gtr-main-title { font-size: 18px; font-weight: bo...
Get in touch with us
Leave a Message, we will call you back quickly!