| Standards | IEC 60305, IEC 62231 |
| Maintenance Advantages | Zero-washing requirement 、Visual defect detection 、 30-year performance warranty |
| Payment Terms | T/T,D/P,D/A,L/C,Western Union |
| Usage | Electrical insulation |
| Uv resistance | Excellent |
| Dry lighting impulse withstand voltage | Up to 150kV |
| Temperature Rating | Up to 200°C |
| Installation method | Pin type or suspension |
| Dimensions | Standardized sizes available |
| Mechanical failing load | 300-550kN |
| Application | Substations、Industrial Dust and Salt Fog Zones etc |
| Brand Name | TL |
View Detail Information
Explore similar products
U100BLP Custom Powerline Insulators Professional Electrical Glass Insulator For
Anti Fog Glass Suspension Insulator High Performance Advanced For Stable Power
U550BP Zero Self Breakage Glass Insulators Anti Pollution Fog Type For Easy
U120BP U160BSP Durable Anti Fog Insulators Chemical Corrosion Resistant
Product Specification
| Standards | IEC 60305, IEC 62231 | Maintenance Advantages | Zero-washing requirement 、Visual defect detection 、 30-year performance warranty |
| Payment Terms | T/T,D/P,D/A,L/C,Western Union | Usage | Electrical insulation |
| Uv resistance | Excellent | Dry lighting impulse withstand voltage | Up to 150kV |
| Temperature Rating | Up to 200°C | Installation method | Pin type or suspension |
| Dimensions | Standardized sizes available | Mechanical failing load | 300-550kN |
| Application | Substations、Industrial Dust and Salt Fog Zones etc | Brand Name | TL |
| High Light | Reliable High Voltage Glass Insulator ,Uv resistance High Voltage Glass Insulator ,Uv resistance powerline insulators | ||
Non-Breakage High Voltage Glass Insulators for Reliable Power Transmission
Enhance substation reliability with our Zero Self-Breakage Anti-Pollution Glass Insulators, engineered for high-voltage transmission networks. Manufactured using advanced annealing and tempering processes, these toughened glass insulators eliminate spontaneous breakage—ensuring consistent operation without unexpected outages.
Designed for polluted environments, the optimized profile inhibits contamination from industrial emissions, salt fog, and moisture. This non-breakage characteristic reduces maintenance frequency, allowing utilities to allocate resources efficiently while maintaining grid stability.
Rated at 550kN mechanical failing load, our insulators combine exceptional dielectric strength with robust durability. Ideal for high-pollution substations, they deliver reliable flashover prevention, simplified upkeep, and extended service life—ensuring uninterrupted power transmission with minimal intervention.
Data Sheet
| Fog Type | Spacing(mm) | Diameter (mm) | Creepage Distance(mm) | Standard Coupling | Mechanical Faiing Load(kN) |
| U70BLP | 146 | 280 | 450 | 16 | 70 |
| U70BLP1 | 146 | 255 | 400 | 16 | 70 |
| U70BLP2 | 146 | 320 | 550 | 16 | 70 |
| U100BLP | 146 | 280 | 450 | 16 | 100 |
| U100BLP1 | 146 | 255 | 400 | 16 | 100 |
| U100BLP2 | 146 | 320 | 550 | 16 | 100 |
| U120BP | 146 | 280 | 450 | 16 | 120 |
| U120BP1 |
146 |
255 | 400 | 16 | 120 |
| U120BP2 | 146 | 320 | 550 | 16 | 120 |
| U160BMP | 155 | 320 | 550 | 20 | 160 |
| U160BMP1 | 155 | 280 | 450 | 20 | 160 |
| U160BLP | 170 | 320 | 550 | 20 | 160 |
| U160BLP1 | 170 | 280 | 450 | 20 | 160 |
| U160BSP | 146 | 320 | 550 | 20 | 160 |
| U160BSP1 | 146 | 280 | 450 | 20 | 160 |
| U210BP | 170 | 320 | 550 | 20 | 210 |
| U210BPL1 | 170 | 280 | 450 | 20 | 210 |
| U240BP | 170 | 320 | 550 | 24 | 240 |
| U240BP1 | 170 | 280 | 450 | 24 | 240 |
| U300B1 | 195 | 320 | 550 | 24 | 300 |
| U300BP | 195 | 380 | 690 | 24 | 300 |
| U300BP1 | 195 | 380 | 635 | 24 | 300 |
| U420BP | 205 | 380 | 620 | 28 | 420 |
| U550BP | 240 | 390 | 710 | 32 | 550 |
![]()
![]()
![]()
![]()
Anti-fog glass insulator fabrication follows integrated precision workflows. Mineral components undergo automated weighing and batching before high-temperature melting at 1500+°C into uniform glass melt. Precision molds shape the extended-leakage anti-pollution profile in one controlled pressing operation. Multi-stage annealing delivers stress-free glass bodies with long-term mechanical stability. Glass shells permanently bond with corrosion-protected fittings through expanding cement and polymer sealing systems. Comprehensive 100% inline testing—laser dimensional verification, mechanical load validation, and high-voltage dielectric assessment under simulated contamination—precedes traceability encoding and protective export packaging. This closed-loop process guarantees consistent flashover prevention in industrial zones with persistent airborne deposits.
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
50000000-58000000
Employee Number:
300~320
Ecer Certification:
Verified Supplier
In 2004, Huzhou Tailun Insulator Co., Ltd. was established in the Huzhou Economic & Technological Development Zone, on the shore of Taihu Lake in the Yangtze River Delta. Over the past two decades, we have remained fully dedicated to the R&D and manufacturing of premium tempered glass insula... In 2004, Huzhou Tailun Insulator Co., Ltd. was established in the Huzhou Economic & Technological Development Zone, on the shore of Taihu Lake in the Yangtze River Delta. Over the past two decades, we have remained fully dedicated to the R&D and manufacturing of premium tempered glass insula...
Get in touch with us
Leave a Message, we will call you back quickly!