| Payment Terms | T/T |
| Delivery Time | 15-30 days |
| Packaging Details | carton |
| MODEL | FP2 24V 7.2KW |
| Product family | FP2 24V 7.2KW |
| Voltage | 21.75 - 28.8 VDC |
| Max power, nominal input | 7200W |
| Max current | 75 A |
| Efficiency | 95 % |
| Frequency | 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz |
| Current | 11.25 ADC |
| Brand Name | Eltek |
| Model Number | FP2 24V 7.2KW |
| Place of Origin | China |
View Detail Information
Explore similar products
Eltek Rectiverter 2U 6kVA Integrated System 6 kVA AC & 4,8 kW DC with Smartpack
Flatpack2 24v Telecom Power System CIO20405
Mean Well 19 Inch Power Supply RCP-1000-12 RC0-1000-24 1000W-1800W
Netsure 801 Telecom Power System 1000A 1500A 2000A Power Cabinet
Product Specification
| Payment Terms | T/T | Delivery Time | 15-30 days |
| Packaging Details | carton | MODEL | FP2 24V 7.2KW |
| Product family | FP2 24V 7.2KW | Voltage | 21.75 - 28.8 VDC |
| Max power, nominal input | 7200W | Max current | 75 A |
| Efficiency | 95 % | Frequency | 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz |
| Current | 11.25 ADC | Brand Name | Eltek |
| Model Number | FP2 24V 7.2KW | Place of Origin | China |
| High Light | Eltek FP2 24V ,Eltek FP2 7.2KW ,Eltek FP2 2U | ||
![]()
The Flatpack2 modular concept has a lot of benefits compared to traditional solutions in the industry. It has high efficiency; less power consumption and heat dissipation. The overall Size and footprint of cabinet is 50% of Thyristor Controlled Size. Modular Hot Plug-in Construction allows redundancy, n+1, n+2 configurations.
It's easy to do repairing with MTTR< 5 minutes.Very high MTBF > 350000 hours, wide input AC Voltage and frequency range.Possibility to build combined systems with rectifiers, DC/DC converters and inverters controlled by one controller.
| Model | 24/1800 HE |
| Part number | 241115.205 |
| INPUT DATA | |
| Voltage (nominal) | 185 - 275 VAC / 185 - 300 VDC |
| Voltage (range) | 85 - 300 VAC / 85 - 300 VDC |
| Frequency | 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz |
| Current (maximum) @ nominal input, full load | 11.25 ADC |
| Power Factor | 0.99 (@ 50-100% load) |
| THD (@ 230 VAC) | < 4 % (@ full load) |
| Protection | Fuse in both lines, varistor for transient protection, shutdown when VIN is out of range |
| OUTPUT DATA | |
| Voltage (default) | 26.75 VDC |
| Voltage (adjustable range) | 21.75 - 28.8 VDC |
| Max power, nominal input | 1800 W |
| Max power, de-rated @VIN = 85 VDC | 750 W |
| Max current, @VOUT ≤ 24 VDC | 75 A |
| Hold-up time, default voltage and 1000 W load | 20 ms, VOUT > 21 VDC |
| Current sharing | ± 5% of maximum current from 10 to 100% load |
| Static voltage regulation (10-100% load) | ±0.5% from 10 - 100% load and supplied power not limited by PV panels |
| Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
| Ripple | < 250 mVPP , 30 MHz bandwidth |
| Psophometric noise | < 2 mVRMS |
| Protection | Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting |
| OTHER SPECIFICATIONS | |
| Peak Efficiency | 95 % |
| Isolation | 3 kVAC – input and output, 1.5 kVAC – input earth, 0.5 kVDC – output earth |
| Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
| Warnings (Yellow LED) | Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
| Normal (Green LED) | Input and output ok |
| MTBF (Telcordia SR-332 Iss.I method III (a)) | >300 000 (@ Tambient : 25 °C) |
| Operating temperature (5 - 95% RH non-cond.) | - 40 -75°C [-40 - 167°F ] |
| Max output power de-rates above temp / to | 45°C [+113°F] / 1200W |
| Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
| Dimensions[WxHxD] / Weight | 109 x 41.0 x 327mm [4.25 x 1.61 x 13”] / 1.950 kg [4.3lbs] |
| DESIGN STANDARDS | |
| Electrical safety | EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013 UL 60950-1:2014 |
| EMC | EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010 IEC 61000-6-5:2015, EN 300 386:v2.1.1, FCC CFR 47 Part 15:2008 |
|
Environment | ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) 2011/65/EU (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
| 1) Maximum power de-rated to 1000W @230Vac & 16 2/3Hz input | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Trading Company
Year Established:
2017
Total Annual:
4,000,000-5,000,000
Employee Number:
20~30
Ecer Certification:
Verified Supplier
Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv... Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv...
Get in touch with us
Leave a Message, we will call you back quickly!