High Voltage Lightning Impulse Generator for Transformer, GIS, Switchgear and

  1. MOQ: 1 Set
  2. Price:
  3. Get Latest Price
Energy Range 7.31–320 kJ
Rated Impulse Voltage ±100 kV to ±4800 kV
Load Capacitance 0.325–1 μF
Delivery Time 30 Working Days
Number of Stages 1–24
Payment Terms T/T,L/C
Packaging Details Plywood Case
Impulse Capacitance 0.0278–0.1625 μF
Maximum Output Up to ±4800 kV
Model Number SXCY
Brand Name Sansion
Certification CE/SGS/EMS/ISO 9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Energy Range 7.31–320 kJ Rated Impulse Voltage ±100 kV to ±4800 kV
Load Capacitance 0.325–1 μF Delivery Time 30 Working Days
Number of Stages 1–24 Payment Terms T/T,L/C
Packaging Details Plywood Case Impulse Capacitance 0.0278–0.1625 μF
Maximum Output Up to ±4800 kV Model Number SXCY
Brand Name Sansion Certification CE/SGS/EMS/ISO 9001
Place of Origin China
High Light High Voltage Lightning Impulse Generator ,Impulse Generator for Transformer Testing ,GIS Switchgear Insulation Withstand Tester

Product Description

The SXCY Series Impulse Voltage and Impulse Current Generator is engineered to reproduce severe transient electrical stresses for insulation performance evaluation and high-voltage equipment testing.

By generating controlled impulse voltage or impulse current, the system helps manufacturers and testing laboratories verify the ability of electrical equipment to withstand lightning-related and other transient overvoltage conditions.

Key Product Highlights

  • 01. High-Energy Impulse Output

    Designed to deliver high-energy impulse output for demanding insulation tests and electrical equipment qualification.

  • 02. Multi-Stage Generator Architecture

    A modular multi-stage structure allows the output voltage to be increased by combining different numbers of generator stages.

  • 03. Broad Voltage Coverage

    System configurations cover approximately ±100 kV to ±4800 kV, providing solutions for a wide range of high-voltage testing applications.

  • 04. Configurable Energy Capacity

    Different capacitance and stage configurations allow the impulse energy to be matched to the characteristics of the test object.

  • 05. Engineered for Large Test Objects

    Suitable for high-voltage equipment requiring substantial impulse energy, including transformers, GIS and other major power apparatus.

  • 06. Application-Specific Engineering

    Generator parameters can be selected according to the required test voltage, energy, test object and laboratory conditions.

Technical Specifications

Parameter Available Range
Rated Impulse Voltage ±100 kV to ±4800 kV
Impulse Capacitance 0.0278–0.1625 μF
Stage Capacitance 0.325–1 μF
Impulse Energy Up to 320 kJ
Damping Resistor ±100 / ±150 / ±200 kV
Number of Stages 1–24
Generator Type Multi-Stage Impulse Generator

FAQ

Q:What is an impulse voltage generator used for?

It is used to generate controlled high-voltage impulses for evaluating the insulation withstand capability of electrical equipment under transient voltage conditions.

Q:What is the difference between lightning impulse and switching impulse?

Lightning impulse testing simulates fast transient overvoltages associated with lightning, while switching impulse testing represents slower transient stresses caused by switching operations in power systems.

Q:What is the maximum voltage available?

Depending on the configuration, the SXCY Series can reach ±4800 kV.

Q:How many stages can the generator have?

The available configurations shown in the product specifications range from 1 to 24 stages.

Q:What determines the required generator size?

The required impulse voltage, test object capacitance, energy requirement, test waveform and applicable testing standard are key factors when selecting the generator configuration.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement