China factories

Chat Now Send Email
China factory - Sansion Power Electric Co., Ltd.

Sansion Power Electric Co., Ltd.

  • China,Wuhan ,Hubei
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS
China GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS

  1. China GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS
  2. China GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS
  3. China GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS

GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Frequency 50Hz/60Hz
Cooling method Air cooling
Capacity Range 50–2000kVA
Delivery Time 30 working days
Power consumption 500W
Payment Terms L/C,T/T
Packaging Details Plywood Case
System Type Resonance voltage generation
Input Voltage 0.35–10kV
Model Number SXGTU
Brand Name Sansion Power
Certification CE/SGS/EMS/ISO 9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Frequency 50Hz/60Hz Cooling method Air cooling
Capacity Range 50–2000kVA Delivery Time 30 working days
Power consumption 500W Payment Terms L/C,T/T
Packaging Details Plywood Case System Type Resonance voltage generation
Input Voltage 0.35–10kV Model Number SXGTU
Brand Name Sansion Power Certification CE/SGS/EMS/ISO 9001
Place of Origin China
High Light GIS partial discharge test system ,AC withstand voltage test equipment ,high voltage GIS testing equipment
Product Description

The GIS Partial Discharge and AC Withstand Voltage Test System is a professional high-voltage testing solution designed for insulation withstand testing and partial discharge measurement of Gas Insulated Switchgear (GIS), Gas Insulated Line (GIL) and related high-voltage equipment.

The system combines high-voltage AC testing, partial discharge measurement, high-precision voltage measurement, digital data acquisition and intelligent control into an integrated testing platform.

It is suitable for GIS manufacturers, power utilities, substations, EPC contractors, commissioning companies, high-voltage laboratories and electrical equipment testing centers.

Current GIS testing solutions commonly combine AC withstand testing with PD measurement and are used for both factory testing and on-site commissioning.

Main Testing Functions
  • GIS AC withstand voltage test
  • GIS partial discharge test
  • GIL AC withstand test
  • GIS insulation performance verification
  • Power-frequency withstand test
  • Variable-frequency AC withstand test
  • Partial discharge measurement
  • PD inception voltage measurement
  • PD extinction voltage measurement
  • PD pattern analysis
  • High-voltage measurement
  • Test data recording
  • Automatic test control
  • Test report generation
Typical Test Objects
  • GIS
  • GIL
  • HGIS
  • GIS busbar
  • GIS circuit breaker
  • GIS disconnector
  • GIS grounding switch
  • GIS instrument transformer
  • GIS insulator
  • GIS bushing
  • Spacer insulator
  • Other HV switchgear components
Application Scenarios

GIS Factory Testing

Used for routine testing and type testing during GIS manufacturing.

Substation Commissioning

Used to verify GIS insulation performance after transportation and installation.

Post-Maintenance Testing

Used after major GIS maintenance, modification or component replacement.

High Voltage Laboratory

Suitable for research, development and certification testing.

Customer Pain Points

Problem 1: GIS passes withstand voltage but still has internal defects.

AC withstand testing and PD measurement provide different information. PD testing can help identify localized insulation defects that may not be revealed by a simple withstand test.

Problem 2: External noise interferes with PD measurement.

For sensitive GIS PD testing, the test system should be designed with low background PD and appropriate shielding, grounding and measurement technology.

Problem 3: Large GIS has high capacitive load.

The test system should be selected according to GIS capacitance, required test voltage, frequency range and test duration.

FAQ

Q: Can this system perform both AC withstand and PD testing?

A: Yes. A combined configuration can perform AC withstand voltage testing and partial discharge measurement.

Q: Can it be used for GIL?

A: Yes. The system can be configured for GIS and GIL according to the test voltage and capacitance requirements.

Q: Is it suitable for on-site testing?

A: Yes. Mobile and variable-frequency configurations can be designed for on-site GIS commissioning.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement