Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"4 Stages 400kV 20kJ Lightning Impulse Test Equipment For High Voltage Testing","imgUrl":"https:\/\/img.chinax.com\/nimg\/b9\/87\/43bda86c3f9680c510cf7f95a757-200x200-1\/4_stages_400kv_20kj_lightning_impulse_test_equipment_for_high_voltage_testing.jpg","attrs":{"Model Number":"SXCY","Rated Stage Voltage":"\u00b1100 kV","Minimum Order Quantity":"1","Stage Capacitance":"1.0 \u03bcF"}}
{"title":"400kV 20kJ Impulse Voltage Generator Lightning Test System For Switchgear","imgUrl":"https:\/\/img.chinax.com\/nimg\/30\/87\/63e0401b6827a1e11498722cbe91-200x200-1\/400kv_20kj_impulse_voltage_generator_lightning_test_system_for_switchgear.jpg","attrs":{"Model Number":"SXCY","Generator Type":"Multi-Stage Marx Impulse Generator","Minimum Order Quantity":"1","Control Method":"Digital Automatic Control System"}}
{"title":"200KV High Voltage Surge Generator Full Wave Impulse Voltage Test Equipment For","imgUrl":"https:\/\/img.chinax.com\/nimg\/6f\/b7\/7ad4d77f863ad2ea65d4a77b81fb-200x200-1\/200kv_high_voltage_surge_generator_full_wave_impulse_voltage_test_equipment_for_transformer_factories.jpg","attrs":{"Model Number":"SXCY","Rated Nominal Voltage":"200 kV","Place of Origin":"China","Rated Energy":"10 kJ"}}
{"title":"Full Wave Lightning Impulse Voltage Test Equipment , Multistage Impulse","imgUrl":"https:\/\/img.chinax.com\/nimg\/f4\/1e\/edff1ff3ca3576d8c5bfad7ead71-200x200-1\/full_wave_lightning_impulse_voltage_test_equipment_2c_multistage_impulse_generator_400kv.jpg","attrs":{"Model Number":"SXCY","Rated Nominal Voltage":"400 kV","Minimum Order Quantity":"1","Stage Capacitor":"1 \u03bcF, 100 kV"}}
{"title":"Automatic Digital Control Lightning Impulse Test System For Transformer","imgUrl":"https:\/\/img.chinax.com\/nimg\/84\/64\/dfb6b638be0b08b7b6ed703a573d-200x200-1\/automatic_digital_control_lightning_impulse_test_system_for_transformer_insulation.jpg","attrs":{"Model Number":"SXCY","Rated Voltage":"\u00b1100 ~ \u00b14800 kV","Minimum Order Quantity":"1","Stage Voltage":"\u00b1100 ~ \u00b1200 kV"}}
{"title":"300kV Compact Lightning Impulse Test Equipment For Transformer Insulation","imgUrl":"https:\/\/img.chinax.com\/nimg\/12\/8d\/1cbb9b8181da76e7528d943aad04-200x200-1\/300kv_compact_lightning_impulse_test_equipment_for_transformer_insulation.jpg","attrs":{"Model Number":"SXCY","Rated Nominal Voltage":"300 kV","Minimum Order Quantity":"1","Stage Capacitor":"1 \u03bcF, 100 kV"}}
{"title":"600kV Impulse Voltage Generator High Voltage Test Equipment For Transformer","imgUrl":"https:\/\/img.chinax.com\/nimg\/9a\/42\/b6292400c9bac9f83033d35040ed-200x200-1\/600kv_impulse_voltage_generator_high_voltage_test_equipment_for_transformer.jpg","attrs":{"Model Number":"SXCY","High Voltage Insulation":"Fully insulated dry-type encapsulation technology","Minimum Order Quantity":"1","Voltage Level":"600kV"}}
The Lightning Impulse Test System is designed for insulation performance verification of high voltage electrical equipment under lightning impulse voltage conditions. The system generates standardized impulse voltage waveforms to simulate lightning overvoltage stresses and evaluate the insulation strength of transformers, GIS, cables, bushings, insulators, and other power equipment.
The impulse voltage generator adopts modular design technology with charging unit, impulse capacitors, multi-stage generator structure, control system, measurement system, and protection devices. It can generate standard lightning impulse voltage waveform (1.2/50μs) according to IEC 60060 requirements for high voltage testing applications.
2. Important Product Parameters
Parameter
Specification
Rated Nominal Voltage
±400 kV
Rated Stage Voltage
±100 kV
Rated Energy
20 kJ
Number of Stages
4 Stages
Stage Capacitance
1.0 μF
Total Impulse Capacitance
0.25 μF
Standard Impulse Waveform
1.2/50 μs Lightning Impulse Voltage Waveform
Charging Voltage Stability
≤ ±1%
Full Capacity Charging Time
180 s
Testing Application
Transformer and High Voltage Electrical Equipment Insulation Testing
3. Product Applications
Power Transformer Manufacturing
Distribution Transformer Testing
GIS Testing Laboratory
High Voltage Cable Testing
Insulator and Bushing Testing
Surge Arrester Testing
Power Equipment Research Laboratory
4. Product Advantages
1. Customized High Voltage SolutionDesigned according to different voltage levels, laboratory conditions, and testing requirements.
2. Accurate Impulse Waveform GenerationProvides stable impulse voltage output to meet insulation verification requirements.
3. Wide Application RangeSuitable for transformer manufacturers, cable factories, power utilities, and HV laboratories.
4. Reliable Safety ProtectionIntegrated control and protection system ensures safe operation during high voltage testing.
5. Complete Testing Solution ProviderSansion Power supports complete high voltage laboratory solutions including impulse testing, AC withstand testing, partial discharge testing, and resonance testing.
5. FAQ
Q1: What is a lightning impulse test system used for?A: It is used to test whether high voltage equipment can withstand transient overvoltage caused by lightning strikes.
Q2: Which equipment can be tested by this system?A: The system is mainly used for transformers, GIS, cables, bushings, insulators, and other high voltage equipment.
Q3: What lightning impulse waveform is generated?A: The standard lightning impulse waveform is 1.2/50μs according to IEC 60060 requirements.
Q4: Can the system be customized for different voltage levels?A: Yes. Sansion Power provides customized solutions according to customer test requirements.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2005
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...