| Delivery Time | 30 Working Days |
| Output Frequency Range | 20~300Hz |
| Waveform Distortion | THD ≤1% |
| Frequency Resolution | 0.01Hz |
| Payment Terms | T/T,L/C |
| Input Power Supply | Single-phase 220V or three-phase 380V |
| Packaging Details | Plywood Case |
| Rated Output Voltage | 0~800kV |
| Frequency Stability | ≤0.01% |
| Model Number | SXBP |
| Certification | CE/SGS/EMS/ISO 9001 |
| Brand Name | Sansion |
| Place of Origin | China |
View Detail Information
Explore similar products
Variable Frequency Series Resonance AC Withstand Voltage Testing System for High
High Voltage Variable Frequency Series Resonance Test System for GIS, Transforme
High Voltage Variable Frequency Series Resonance Test System High Voltage AC
20–300 Hz 108kV Modular Structure Series Resonant Test System for AC Resonant
Product Specification
| Delivery Time | 30 Working Days | Output Frequency Range | 20~300Hz |
| Waveform Distortion | THD ≤1% | Frequency Resolution | 0.01Hz |
| Payment Terms | T/T,L/C | Input Power Supply | Single-phase 220V or three-phase 380V |
| Packaging Details | Plywood Case | Rated Output Voltage | 0~800kV |
| Frequency Stability | ≤0.01% | Model Number | SXBP |
| Certification | CE/SGS/EMS/ISO 9001 | Brand Name | Sansion |
| Place of Origin | China | ||
| High Light | Variable Frequency Series Resonance Test System ,High Precision Series Resonance Hipot Tester ,High Voltage Test System for Power Plant | ||
The SXBP portable variable frequency series resonance test set is a high-voltage test equipment developed by our company to meet the demands of on-site AC withstand voltage tests in the power industry. Adopting the variable frequency resonance principle, it adjusts the output frequency to make the reactor resonate with the capacitance of the test object, so as to obtain stable high voltage on the test sample. It is suitable for AC withstand voltage tests of power cables, GIS, circuit breakers, instrument transformers, power transformers and other high-voltage equipment up to 110kV.
| Item | Parameter |
|---|---|
| Rated Output Voltage | 0~800kV (RMS, customized on request) |
| Output Frequency Range | 20~300Hz |
| Resonant Voltage Waveform | Sine wave, THD ≤1% |
| Continuous Working Time at Full Load | 15min / 60min (depends on configuration) |
| System Quality Factor | ≥20 under maximum load |
| Frequency Adjustment Resolution | 0.01Hz |
| Frequency Instability | ≤0.01% |
| Input Power Supply | Single-phase 220V or 3-phase 380V |
| Operation Mode | Automatic / Manual |
| Protection Functions | Overvoltage, Overcurrent, Flashover, Zero-position Start |
| Data Functions | Parameter Setting, Status Display, Data Storage, Historical Query |
Q1: What tests can the SXBP portable variable frequency series resonance set perform?
A: It is mainly used for AC withstand voltage tests of power cables, GIS, circuit breakers, instrument transformers, transformers, generators and motors up to 110kV, which is critical equipment to inspect insulation performance of high-voltage apparatus.
Q2: What is the difference between variable frequency series resonance test and traditional power frequency withstand voltage test?
A: Traditional power frequency withstand voltage equipment is bulky and heavy, inconvenient for field deployment. Variable frequency series resonance generates high voltage via resonance principle, with the strengths of small footprint, light weight, good waveform and high efficiency, more suitable for on-site tests.
Q3: What length of cable can this equipment test?
A: The maximum testable cable length depends on system capacity, voltage level, cable capacitance and test frequency range. We can configure suitable resonance schemes according to your cable voltage grade, cross-section and length.
Q4: Can the reactors be freely combined?
A: Yes. The reactors adopt building-block structure. They can be connected in series or parallel to adjust output voltage and load capacity to match different test samples.
Q5: What power supply is required on site?
A: It supports single-phase 220V or three-phase 380V. The actual power supply depends on equipment capacity and site conditions. 3-phase 380V is recommended for large-capacity units to guarantee stable power supply.
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2005
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...
Get in touch with us