| Output frequency | 100-150 Hz |
| Power control | Three-phase four-wire |
| Temperature channels | Multichannel measurement |
| Delivery Time | 30 Working Days |
| Test items | Ratio, Winding Resistance, No-Load Loss, Load Loss, Induced Voltage Withstand, Temperature Rise |
| Measurement units | DC resistance, Ratio and vector group, Temperature inspection |
| Data processing | Automatic correction and conversion |
| Payment Terms | L/C,T/T |
| Test power | Frequency-multiplying generator |
| Packaging Details | Plywood Case |
| Control system | Computer-based |
| Model Number | SXBZ-II |
| Brand Name | Sansion Power |
| Place of Origin | China |
| Certification | CE/SGS/EMS/ISO 9001 |
View Detail Information
Explore similar products
Transformer Test Console with Integrated Digital Measurement and Centralized
Three-Phase Transformer Test Bench for Factory Routine Testing, Precision
Automatic Transformer Comprehensive Test Bench for Distribution and Power
Automatic Transformer Comprehensive Test Bench for Turns Ratio, Winding
Product Specification
| Output frequency | 100-150 Hz | Power control | Three-phase four-wire |
| Temperature channels | Multichannel measurement | Delivery Time | 30 Working Days |
| Test items | Ratio, Winding Resistance, No-Load Loss, Load Loss, Induced Voltage Withstand, Temperature Rise | Measurement units | DC resistance, Ratio and vector group, Temperature inspection |
| Data processing | Automatic correction and conversion | Payment Terms | L/C,T/T |
| Test power | Frequency-multiplying generator | Packaging Details | Plywood Case |
| Control system | Computer-based | Model Number | SXBZ-II |
| Brand Name | Sansion Power | Place of Origin | China |
| Certification | CE/SGS/EMS/ISO 9001 | ||
| High Light | Transformer test system with ratio testing ,Power transformer winding resistance tester ,Transformer no-load loss test system | ||
The SXBZ-II Transformer Comprehensive Test System is designed for power transformer manufacturers and transformer testing facilities. It integrates multiple measurement units, power supply equipment, control cabinets, and compensation systems to perform transformer routine tests and specialized performance evaluations. The specified test items include voltage ratio and vector group measurement, winding DC resistance measurement, no-load loss and no-load current testing, load loss and short-circuit impedance measurement, induced voltage withstand testing, and temperature rise testing.
The complete system consists of the following main units:
Automatic Test Control: Supports three-phase four-wire power control, regulator power control, voltage adjustment, transformer tap selection, auxiliary cabinet switching, and test-function activation or deactivation.
Electrical Parameter Monitoring: Monitors the required voltage and current during individual test procedures.
Computerized Operation: Provides computer-based control and automatic storage of test results.
Comprehensive Transformer Testing: Supports ratio and vector group, winding DC resistance, no-load, load, induced voltage withstand, and temperature rise tests.
Automatic Data Processing: The no-load and load testing unit supports measurement correction, while load-loss results can be converted to specified reference temperatures.
Temperature Recording: The temperature inspection unit supports multichannel measurement, data storage, temperature curve display, and report printing through the configured software.
Q1: What tests can the system perform?
A: It supports voltage ratio and vector group testing, winding DC resistance testing, no-load testing, load and short-circuit impedance testing, induced voltage withstand testing, and temperature rise testing.
Q2: Can the system automatically save test results?
A: Yes. The computer-based control system supports automatic test-result storage, while individual measurement units provide their specified data storage and export functions.
Q3: What is the function of the frequency-multiplying generator set?
A: It provides a higher-frequency power source for transformer induced voltage withstand and partial discharge testing. The specified setup provides an output frequency of 100–150 Hz, with 150 Hz used for the described application.
Q4: Can the system configuration be customized?
A: The configuration should be confirmed according to transformer ratings, required test items, and project conditions. The final technical proposal should specify the selected measurement units and supporting equipment.
Company Details
Business Type:
Manufacturer
Year Established:
2005
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...
Get in touch with us
Leave a Message, we will call you back quickly!